首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 54 毫秒
1.
Advancing in the learning curve of solar thermal power plants (STPP) requires detailed analysis for reducing exergy losses in the energy conversion chain. This requirement should be applied to any configuration proposed for the solar field and the power block. The aim of this work is to perform this type of analysis for two ways of structuring the power plant. The first plant structure consists of a subdivision of the solar collector field into specialized sectors with specific goals conveying different requirements in temperature. The second plant structure is based on a dual thermal energy storage system with a defined hierarchy in the storage temperature. The subdivision of the solar field into different sectors reduces the exergy losses in the heating process of the working fluid. Moreover, the average temperature of the heat transfer fluid in the solar field decreases when it is compared to the conventional solar field, reducing this way the exergy losses in the collectors. The dual thermal energy storage system is devised for keeping the exergy input to the power block at its nominal level for long periods of time, including post‐sunset hours. One of the storage systems gathers a fluid heated up to temperatures above the nominal value and the second one is the classical one. The combination of both allows the manager of the plant to keep the nominal operation of the plant for longer periods than in the case of classical system. Numerical simulations performed with validated models are the basis of the exergy analyses. The configurations are compared to a reference STPP in order to evaluate their worth. Furthermore, the behaviour of the configurations is analysed to study the irreversibility of the included devices. Special attention is paid to the storage systems, as they are a key issue in both plant structures. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
Energy storage is one of the most important components of renewable energy systems. Among different methods, thermal energy storage (TES) in forms of sensible or latent has been the subject of many studies in the past decades. The main difficulty in optimal design of storage tanks is associated with low thermal conductivity of the storing (solid or phase change) material. In fact, the distribution of thermal energy from a source to the body of storing material poses a volume to point problem which is the subject of constructal theory. Therefore, the objective of the present paper is to investigate the transient behavior of a rectangular thermal energy storage tank equipped with fin configurations optimized for heat conduction based on constructal theory. Results of numerical simulations reveal that the more complex configurations perform better in sensible TES systems; almost as well as what is expected based on analytical steady state solutions. However, because of the convection currents in the melting process of a PCM tank, the final full charging time of the latent systems are approximately the same.  相似文献   

3.
A salinity gradient solar pond (SGSP) is a simple and effective way of capturing and storing solar energy. The Qinghai-Tibet Plateau has very good solar energy resources and very rich salt lake brine resources. It lacks energy for its mineral processes and is therefore an ideal location for the development and operation of solar ponds. In China, solar ponds have been widely applied for aquaculture, in the production of Glauber’s salt and in the production of lithium carbonate from salt lake. As part of an experimental study, a SGSP using the natural brine of Zabuye salt lake in the Tibet plateau has been constructed. The pond has an area of 2500 m2 and is 1.9 m deep. The solar pond started operation in spring when the ambient temperature was very low and has operated steadily for 105 days, with the LCZ temperature varying between 20 and 40 °C. During the experimental study, the lower convective zone (LCZ) of the pond reached a maximum temperature of 39.1 °C. The results show that solar ponds can be operated successfully at the Qinghai-Tibet plateau and can be applied to the production of minerals.  相似文献   

4.
Three types of no-salt solar ponds, which do not exhibit environmental or operational problems of the kind observed for salt ponds, are examined on a laboratory scale. The negative temperature gradient necessary for heat storage was obtained by using appropriate arrangements in such a way that narrow passages appear which reduce substantially the heated water currents, or by using two (or more) transparent immiscible liquids which constitute a density gradient serving the same purpose. The influence of the dissolved air in the water mass is discussed.  相似文献   

5.
常茹  高娟 《节能》2011,(10):53-55
针对北方农村居民使用火炕的生活习惯,在传统火炕的基础上,设计一种与太阳能-空气源热泵系统相结合的新型盘管火炕系统.利用太阳能低温地板辐射技术改造传统火炕,在保持传统火炕风貌的同时,进一步提高采暖的舒适性,是一次利用新技术对传统取暖方式进行改良的新探索.  相似文献   

6.
In the present communication, a generalized procedure has been described for the performance evaluation of a solar air heater with N‐subcollectors with identical collector aspect ratio connected in various combinations such as in series, parallel and series–parallel. It has been found that the performance of a solar air heating system can be improved by operating several subcollectors in series in place of a single large collector with the same total area. Results have been presented to show the effect of various design parameters, viz. collector aspect ratio, mass flow rate, etc. on the performance of solar air heater with N‐subcollectors in series, parallel and series–parallel combinations. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

7.
Parabolic trough solar collector usually consists of a parabolic solar energy concentrator, which reflects solar energy into an absorber. The absorber is a tube, painted with solar radiation absorbing material, located at the focal length of the concentrator, usually covered with a totally or partially vacuumed glass tube to minimize the heat losses. Typically, the concentration ratio ranges from 30 to 80, depending on the radius of the parabolic solar energy concentrator. The working fluid can reach a temperature up to 400°C, depending on the concentration ratio, solar intensity, working fluid flow rate and other parameters. Hence, such collectors are an ideal device for power generation and/or water desalination applications. However, as the length of the collector increases and/or the fluid flow rate decreases, the rate of heat losses increases. The length of the collector may reach a point that heat gain becomes equal to the heat losses; therefore, additional length will be passive. The current work introduces an analysis for the mentioned collector for single and double glass tubes. The main objectives of this work are to understand the thermal performance of the collector and identify the heat losses from the collector. The working fluid, tube and glass temperature's variation along the collector is calculated, and variations of the heat losses along the heated tube are estimated. It should be mentioned that the working fluid may experience a phase change as it flows through the tube. Hence, the heat transfer correlation for each phase is different and depends on the void fraction and flow characteristics. However, as a first approximation, the effect of phase change is neglected. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
提出了一种与太阳能空气集热器结合的定形相变蓄能地板采暖系统充分利用太阳能.白天,由太阳能空气集热器加热后的热空气通过保温管道输送到相变地板夹层,相变材料(PCM)蓄热;夜间,房间的冷空气进入相变地板夹层,被加热后送入房间,相变材料放热.可行性实验研究表明,此采暖系统安全可靠,能显著提高窒内温度,房间各处受热均匀,热舒适性较好,有一定的应用前景.  相似文献   

9.
Measurements are reported on some manifolds of the fluid in glass type for evacuated all-glass tubular collectors. Temperatures at the closed end of glass tubes were measured while heating the tubes electrically to simulate solar energy input. Both parallel and series connection of the tubes are considered. The results show that thermosiphon effects can be used to achieve balanced flows in the parallel configuration, and for both parallel and series configurations efficient heat extraction can be achieved from the tubes with no partitioning of the inner volume of the tubes.  相似文献   

10.
An analytical and computational model for a solar assisted heat pump heating system with an underground seasonal cylindrical storage tank is developed. The heating system consists of flat plate solar collectors, an underground cylindrical storage tank, a heat pump and a house to be heated during winter season. Analytical solution of transient field problem outside the storage tank is obtained by the application of complex finite Fourier transform and finite integral transform techniques. Three expressions for the heat pump, space heat requirement during the winter season and available solar energy are coupled with the solution of the transient temperature field problem. The analytical solution presented can be utilized to determine the annual variation of water temperature in the cylindrical store, transient earth temperature field surrounding the store and annual periodic performance of the heating system. A computer simulation program is developed to evaluate the annual periodic water and earth temperatures and system performance parameters based on the analytical solution. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
In this experimental study, solar energy was stored daily using the volcanic material with the sensible heat technique. The external heat collection unit consisted of 27 m2 of south‐facing solar air collectors mounted at a 55° tilt angle. The dimensions of the packed‐bed heat storage unit were 6 × 2 × 0.6 m deep. The packed‐bed heat storage unit was built under the soil. The heat storage unit was filled with 6480 kg of volcanic material. Energy and exergy analyses were applied in order to evaluate the system efficiency. During the charging periods, the average daily rates of thermal energy and exergy stored in the heat storage unit were 1242 and 36.33 W, respectively. Since the rate of exergy depends on the temperature of the heat transfer fluid and surrounding, the rate of exergy increased as the difference between the inlet and outlet temperatures of the heat transfer fluid increased during the charging periods. It was found that the average daily net energy and exergy efficiencies in the charging periods were 39.7 and 2.03%, respectively. The average daily net energy efficiency of the heat storage system remained nearly constant during the charging periods. The maximum energy and exergy efficiencies of the heat storage system were 52.9 and 4.9%, respectively. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

12.
In order to investigate the performance of the combined solar–heat pump system with energy storage in encapsulated phase change material (PCM) packings for residential heating in Trabzon, Turkey, an experimental set‐up was constructed. The experimental results were obtained from November to May during the heating season for two heating systems. These systems are a series of heat pump system, and a parallel heat pump system. The experimentally obtained results are used to calculate the heat pump coefficient of performance (COP), seasonal heating performance, the fraction of annual load meet by free energy, storage and collector efficiencies and total energy consumption of the systems during the heating season. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

13.
A. Saleh  J.A. Qudeiri 《Energy》2011,36(2):922-931
Solar ponds provide the most convenient and least expensive option for heat storage for daily and seasonal cycles. This is particularly important for a desalination facility, if steady and constant water production is required. If, in addition to high storage capacity, other favorable conditions exist, the salt gradient solar ponds (SGSPs) are expected to be able to carry the entire load of a large-scale flash desalination plants without dependence upon supplementary sources. This paper presents a performance investigation of a SGSP coupled with desalination plant under Jordanian climatic conditions. This is particularly convenient in the Dead Sea region characterized by high solar radiation intensities, high ambient temperature most of the year, and by the availability of high concentration brine. It was found that a 3000 m2 solar pond installed near the Dead Sea is able to provide an annual average production rate of 4.3 L min−1 distilled water compared with 3.3 L min−1 that would be produced by El Paso solar pond, which has the same surface area. Based on this study, solar ponds appear to be a feasible and an appropriate technology for water desalination near the Dead Sea in Jordan.  相似文献   

14.
In this work, a unified renewable energy system has designed to assess the electricity and hydrogen production. This system consists of the evacuated tube solar collectors (ETSCs) which have the total surface area of 300 m2, a salt gradient solar pond (SGSP) which has the surface area of 217 m2, an Organic Rankine Cycle (ORC) and an electrolysis system. The stored heat in the heat storage zone (HSZ) transferred to the input water of the ETSCs by means of an exchanger and thereby ETSCs increase the temperature of preheated water to higher level as much as possible that primarily affects the performance of the ORC. The balance equations of the designed system were written and analyzed by utilizing the Engineering Equations Solver (EES) software. Hence, the energy and exergy efficiencies of the overall system were calculated as to be 5.92% and 18.21%, respectively. It was also found that hydrogen generation of the system can reach up to ratio 3204 g/day.  相似文献   

15.
Sun is an inexhaustible source of energy capable of fulfilling all the energy needs of humankind. The energy from the sun can be converted into electricity or used directly. Electricity can be generated from solar energy either directly using photovoltaic (PV) cells or indirectly using concentrated solar power (CSP) technology. Progress has been made to raise the efficiency of the PV solar cells that can now reach up to approximately 34.1% in multi‐junction PV cells. Electricity generation from concentrated solar technologies has a promising future as well, especially the CSP, because of its high capacity, efficiency, and energy storage capability. Solar energy also has direct application in agriculture primarily for water treatment and irrigation. Solar energy is being used to power the vehicles and for domestic purposes such as space heating and cooking. The most exciting possibility for solar energy is satellite power station that will be transmitting electrical energy from the solar panels in space to Earth via microwave beams. Solar energy has a bright future because of the technological advancement in this field and its environment‐friendly nature. The biggest challenge however facing the solar energy future is its unavailability all‐round the year, coupled with its high capital cost and scarcity of the materials for PV cells. These challenges can be met by developing an efficient energy storage system and developing cheap, efficient, and abundant PV solar cells. This article discusses the solar energy system as a whole and provides a comprehensive review on the direct and the indirect ways to produce electricity from solar energy and the direct uses of solar energy. The state‐of‐the‐art procedures being employed for PV characterization and performance rating have been summarized . Moreover, the technical, economic, environmental, and storage‐related challenges are discussed with possible solutions. Furthermore, a comprehensive list of future potential research directions in the field of direct and indirect electricity generation from solar energy is proposed.  相似文献   

16.
A novel hybrid PVT/parabolic trough concentrator (PTC)/organic Rankine cycle (ORC) solar power system integrated with underground heat exchanger has been proposed. The evaporator unit consists of a transparent flat PVT solar collector and a PTC connected in series. The first transparent solar collector has transparent covers and consists of solar cells totally immersed within a pressurized transparent organic fluid that allows the solar radiation to reach the solar cells, cools them effectively, and captures all thermal losses from the solar cells. The second concentrator is a conventional one with opaque black receiver used to reheat the transparent organic fluid to higher temperatures. Both solar collectors (the PVT and PTC) perform as the boiler and superheater for the ORC. The performance of the proposed system is investigated by a steady‐state mathematical model. The results show that, at design conditions, the efficiency of the PV modules stabilizes around 12%, absorber efficiency varies within 64% to 75%, and the ORC efficiency varies within 7% to 17%.  相似文献   

17.
徐阳  岳晨  高鹏举 《太阳能学报》2022,43(12):531-539
针对给定太阳日辐射曲线,研究集成蓄热单元的太阳光热系统的整体能量的动态转化特性及关键参数影响规律。结果表明:填料床总储热量与传热流体进口流速呈非线性变化,当传热流体进口流速 uf =0.006 m/s时,填料床总储热量最大;在给定填料总容量和uf =0.006 m/s的条件下,填料床高径比为5的填料床具有更高的储热能力;在该计算条件下,uf =0.006 m/s、填料床高径比为5及填料量相对值为1时,太阳光热能实现最大程度上的转化和储存。  相似文献   

18.
This research work investigates the power‐current (P‐I) and voltage‐current (V‐I) characteristics of the thermoelectric modules (TEMs) in series‐parallel configurations under homogeneous and heterogeneous temperature difference (ΔT) condition. To study its performance, 5 different series‐parallel combinations were formed using 16 TEMs. The comparisons among the different configurations have been done to determine the optimal series‐parallel configuration. The total load power extracted from 16 individually connected TEMs was 18.2 W, which was placed as a reference load power. The optimal series‐parallel combination for maximizing the load power is square series‐parallel configuration, whose maximum load power is 95.5%, compared to the reference load power. Moreover, in square series‐parallel configuration, the total internal resistance value that remains constant is equal to the internal resistance of a single TEM, and the total open‐circuit voltage increases gradually on adding any number of TEMs. Thus, it produces higher load voltage and higher load current simultaneously, which is recommended to power DC micro‐grid applications. Furthermore, the series, parallel, and square series‐parallel configurations are connected as star to obtain 3 separate DC output to power the same application. The performance of TEMs under various configurations is analyzed, and the obtain results are verified experimentally.  相似文献   

19.
A model for predicting the salt gradient solar pond (SGSP) area that could be maintained with a given water supply is presented together with several specific applications. For example, based on 30-year average water flows, the model predicts that 1.93 × 109 m2 (477,000 acres) of solar ponds, 1.02 × 109 m2 (253,000 acres) of evaporation ponds to recycle salt, and 0.51 × 109 m2 (125,000 acres) of freshwater storage reservoirs could be maintained at the Great Salt Lake of Utah. Water use requirements per unit of electrical energy from solar ponds are calculated as 600,000 m3/MW·yr. This is roughly 30 times the water evaporated per unit of electrical energy from coal-fired generating plants using wet cooling towers, but substantially less than water evaporation losses per unit of electrical energy produced from typical hydropower dams and reservoirs. It is concluded that water use requirements for solar ponds, although not necessarily prohibitive, are substantial; and in many locations may be the physical factor that limits solar pond development.  相似文献   

20.
太阳能是一种取之不尽用之不竭的清洁能源,但存在分散性强、能量密度低、不稳定等特点,因此为了得到高能量密度和稳定的能量供应,需要解决聚光和储能两大问题。针对这两个问题,本文采用非跟踪低倍聚光的集热器和保温效果良好的储热油箱,提出了一种非跟踪低倍聚光热管式真空管集热器;基于几何光学原理,模拟了热管式真空管和半圆聚光器的不同放置方式和位置的聚光效率,制作了半圆形聚光热管式真空管集热器系统,选择了合适的储热油箱并进行了保温效果的理论计算;最后对该系统进行了集热性能测试实验。实验结果表明,在半圆形聚光器的聚光下,系统的瞬时效率截距为0.66,热损系数为2.53 W/(m2•℃)。该系统完全能够满足人们的日常生活用热的需求,具有良好的应用前景。  相似文献   