首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Seven patients with pulmonary regurgitation (PR), normal pulmonary artery (PA) pressures and large left-to-right atrial shunts are reported. Six had secundum atrial septal defects (ASD) and one had anomalous pulmonary venous drainage. These comprised 4% of 180 patients with atrial shunts and normal PA pressures. Pulmonary regurgitation was diagnosed clinically by mid-frequency diastolic decrescendo murmurs beginning after the pulmonic component of the second heart sound, and diagnoses were confirmed by catheterization. In two patients who had serial preoperative catheterizations over 8 and 16 years, PR progressed in one and was present only on the second study in the other. All patients underwent shunt correction, at which time the pulmonic anulus and artery appeared dilated, but the pulmonic valves were normal and did not require revision. In all patients the PR murmur disappeared after shunt correction alone, and on chest X-ray both PA and overall heart size decreased. Although it is known that pulmonary regurgitation occurs with atrial septal defects and pulmonary hypertension, the present study demonstrates that it also occurs with high flow atrial shunts, in which setting it has different implications and is reversible with shunt correction alone.  相似文献   

2.
Respiratory rate, tidal volume, dynamic lung compliance, functional residual capacity, and pulmonary resistance were measured withim 24 hours of cardiac catheterization in 25 infants, 12 of whom had increased pulmonary blood flow and 13 of whom had decreased PBF. There were no differences in the two groups of patients with respect to VT and FRC. Respiratory rate and pulmonary resistance were higher in infants with increased PBF. Lung compliance was significantly lower in infants with increased PBF (4.9 ml/cm H2O) than in those with decreased PBF (8.9 ml/cm H2O) (P less than 0.01). The decrease in CL in infants with increased PBF significantly correlated with mean pulmonary artery pressure (r = 0.798). No correaltion was found between CL and left atrial pressure or magnitude of the left-to-right shunt. Compliance was normal in patients with increased PBF and normal PAP, suggesting that PAP and not PBF is the primary factor that affects CL in patients with intracardiac left-to-right shunts.  相似文献   

3.
Right and left ventricular volume characteristics were determined from biplane cineangiocardiography in 37 patients with isolated ventricular septal defects. Patients were divided into three categories as determined by the degree of left-to-right shunt: small shunt-less than 35% of pulmonary blood flow (N=9); moderate shunt-35-49% (N=8), and large shunt-greater than 50% (N=20). Right ventricular (RV) end-diastolic volume was increased above normal in 15 of 20 studies performed in patients with large left-to-right shunts and averaged 159 +/- 10% of normal (P less than 0.001). In contrast, only one of the patients in the small shunt group and only half of the patients in the moderate shunt group showed increases in RV end-diastolic volume. The increase in RV volume was proportional to the corresponding increase in left ventricular end-diastolic volume, with the right ventricle ranging from 48 to 116% of LV end-diastolic volume (average 83%). Right ventricular ejection fraction was normal in all patient groups. Right ventricular outpur was increased commensurate with the increases in the RV end-diastolic volume. These data indicate that substantial augmentation in RV end-diastolic volume does occur in patients with isolated ventricular septal defects and large left-to-right shunts. These data can be explained by the significant diastolic and "isovolumic" shunting from left ventricle to right ventricle which occurs in these patients.  相似文献   

4.
We performed successful balloon pulmonary valvuloplasty (BPV) in 6 patients with pulmonary valve stenosis and atrial septal defect (ASD) accompanied by atrial left-to-right shunt without an increase of shunting immediately after BPV. It suggests that such patients should be treated by BPV initially and the need for ASD repair can be assessed during long-term follow-up.  相似文献   

5.
OBJECTIVES: This study reports our clinical experience with transcatheter closure of secundum atrial septal defects (ASDs) in children, using the Amplatzer, a new occlusion device. BACKGROUND: None of the devices previously used for transcatheter closure of interatrial communications has gained wide acceptance. METHODS: We examined the efficacy and safety of the Amplatzer, a new self-centering septal occluder that consists of two round disks made of Nitinol wire mesh and linked together by a short connecting waist. Sixteen patients with secundum ASD met established two- and three-dimensional echocardiographic and cardiac catheterization criteria for transcatheter closure. The Amplatzer's size was chosen to be equal to or 1 mm less than the stretched diameter. The device was advanced transvenously into a 7F long guiding sheath and deployed under fluoroscopic and ultrasound guidance. Once its position was optimal, it was released. RESULTS: The mean ASD diameter by transesophageal echocardiography was 14.1+/-2.3 mm and was significantly smaller (p < 0.001) than the stretched diameter of the ASD (16.8+/-2.4 mm). The mean device diameter was 16.6+/-2.3 mm. No complications were observed. After deployment of the prosthesis, there was no residual shunt in 13 (81.3%) of 16 patients. In three patients there was trivial residual shunt immediately after the procedure that had disappeared in two of them at the 3-month follow-up. CONCLUSIONS: The Amplatzer is an efficient prosthesis that can be safely applied in children with secundum ASD. However, a study including a large number of patients and a longer follow-up period are required before this technique can be widely used.  相似文献   

6.
From February 1992 to November 1995, four French teams used the Sideris button occluder to close 122 ostium secundum, foramen ovale or surgical fenestration atrial septal defects in 121 patients aged 2 to 79 years with body weights of 10 to 96 kg. a left-to-right shunt in 110 cases (average QP/QS = 2.09) or right-to-left shunt in 12 cases. The usual type of prosthesis was used in 115 cases, 8 centered on a guide wire, reverse type in 5 cases and the "centering-device" type in 2 patients. Nineteen implantation attempts were abandoned before releasing the prosthesis. The immediate results were: closure of the atrial septal defect in 116 patients: 59 were completely occluded, 43 had minimal residual shunts. Five patients were operated for non-buttoning or malposition of the prosthesis. In one other case, the device was removed by catheterisation. During follow-up ranging from 1 month to 3 years, 20 patients were operated for varying complications, the commonest of which was malposition of the prosthesis (17 cases) with a shunt of variable volume. In one other case, a second device was inserted. Seventy-seven patients were reviewed at 1 year, 28 a 2 years and 6 at 3 years. The residual shunts decreased with time but only completely disappeared in half the cases. Secondary fractures not requiring surgery were observed in 5 patients. Failures and complications were the result of various causes which are discussed. Successive technological improvements and the experience of the medical teams should reduce this incidence, but caution is required especially in the treatment of young children.  相似文献   

7.
STUDY OBJECTIVES: Pulmonary hypertension is the most important complication in patients with atrial septal defect (ASD), but its role in limiting exercise has not been examined. This study sought to evaluate exercise performance in adults with ASD and determine the contribution of elevated pulmonary artery pressure in limiting exercise capacity. DESIGN: We used Doppler echocardiography during exercise in 10 adults (aged 34 to 70 years) with isolated ASD (New York Heart Association class I, II) and an equal number of matched control subjects. Incremental exercise was performed on an electrically braked upright cycle ergometer. Expired gases and VE were measured breath-by-breath. Two-dimensional and Doppler echocardiographic images were obtained at rest prior to exercise to determine ASD size, stroke volume (SV), shunt ratio (Qp:Qs), right ventricular outflow tract (RVOT) size, and right ventricular systolic pressure at rest (RVSPr). Doppler echocardiography was repeated at peak exercise to measure right ventricular systolic pressure during exercise (RVSPex). RESULTS: Resting echocardiography revealed that RVOT was larger (21+/-4 vs 35+/-8 mm, mean+/-SD; p=0.0009) and RVSPr tended to be higher (17+/-8 vs 31+/-8 mm Hg; p=0.08) in ASD; however, left ventricular SV was not different (64+/-23 vs 58+/-23 mL; p>0.05), compared with control subjects. Despite normal resting left ventricular function, ASD patients had a significant reduction in maximum oxygen uptake (VO2max) (22.9+/-5.4 vs 17.3+/-4.2 mL/kg/min; p=0.005). RVSPex was higher (19+/-8 vs 51+/-10 mm Hg; p=0.001) and the mean RVSP-VO2 slope (1+/-2 vs 18+/-3 mm Hg/L/min; p=0.003) and intercept (17+/-4 vs 27+/-4 mm Hg; p=0.05) were higher in the ASD group. VO2max correlated inversely with both RVSPr (r=-0.69; p=0.007) and RVSPex (r=-0.67; p=0.01). CONCLUSION: These findings suggest that adults with ASD have reduced exercise performance, which may be associated with an abnormal increase in pulmonary artery pressure during exercise.  相似文献   

8.
OBJECTIVES: To determine the appropriate indications and timing for surgery in children with either a perimembranous or a subarterial type of ventricular septal defect (VSD) associated with aortic cusp prolapse. DESIGN: Retrospective review of children with VSD and associated aortic cusp prolapse with or without aortic regurgitation. This review was based on data obtained from clinical findings, two-dimensional echocardiography, cardiac catheterization and angiocardiography. SETTING: Tertiary health care facility with two-dimensional and colour Doppler echocardiographic and cardiac surgery facilities, and a catheterization laboratory. PATIENTS: Forty-eight patients were found to have perimembranous or subarterial VSDs in association with aortic cusp prolapse with or without aortic regurgitation. INTERVENTIONS: All 48 patients had high resolution two-dimensional and colour Doppler echocardiography. Of the 19 patients who underwent surgical closure of their VSD, five also had an aortic valvuloplasty and one had an aortic valve replacement. Cardiac catheterization was performed in 16 of the 19 surgical patients and 12 of the 29 nonsurgical patients. MEASUREMENTS AND MAIN RESULTS: Annual clinical and echocardiographic assessments in the nonsurgical group did not demonstrate increasing aortic insufficiency. Two children in the nonsurgical group showed spontaneous resolution of aortic insufficiency. In the surgical group, four children with VSD and clinical aortic insufficiency had surgery at less than five years of age; two were found to be regurgitant-free, one had trivial clinical aortic insufficiency and the other had echocardiography-only insufficiency. Of the seven surgical patients older than five years with VSD and clinical aortic insufficiency, four were found to be regurgitant-free, one had echocardiography-only regurgitation and two were unchanged. Two children undergoing surgery with VSD and no aortic insufficiency had postoperative echocardiography-only regurgitation, presumably related to cusp deformity from presurgical prolapse. Children with large VSDs with or without aortic cusp prolapse required surgery for indications of shunt size and pulmonary resistance. CONCLUSIONS: For children with small perimembranous VSDs and cusp prolapse, surgery is indicated only if there is clinical evidence of aortic regurgitation and progressive left ventricular enlargement.  相似文献   

9.
One hundred and thirty patients with various heart diseases who underwent angiocardiography were studied to assess the clinical usefulness of echocardiographic aortic root diameter. The echocardiographic aortic root diameter was measured from the anterior surface of the anterior wall to the anterior surface of the posterior wall at end-diastole. A significant correlation was found between aortic root diameters measured by angiocardiograms and those by echocardiograms (r = 0.944, p less than 0.001). The aortic root diameter in normal subjects was 15 to 40 mm with a mean value of 29.0 mm. The corrected aortic root diameter by body surface area in normal subjects ranged from 10.1 to 29.5 mm/M2 with a mean value of 19.18 mm/M2. There appeared to be direct relationship between corrected aortic root diameter and the age. Echocardiography is a simple, safe, and reliable noninvasive method for estimating aortic root diameter.  相似文献   

10.
AIMS: The aim of this study was to develop a technique to measure collateral blood flow in portal hypertensive rats. METHODS: Morphological techniques included inspection, casts and angiographies of portosystemic shunts. The main hemodynamic measurements were splenorenal shunt blood flow (transit time ultrasound method), percentage of portosystemic shunts and regional blood flows (microsphere method). In study 1, a model of esophageal varices was developed by ligating the splenorenal shunt. In study 2, morphological studies of the splenorenal shunt were performed in rats with portal vein ligation. In study 3, the relationship between splenorenal shunt blood flow with percentage of portosystemic shunts was evaluated in dimethylnitrosamine cirrhosis. In study 4, secondary biliary, CCl4 and dimethylnitrosamine cirrhosis were compared. In study 5, rats with portal vein ligation received acute administration of octreotide. In study 6, rats with dimethylnitrosamine cirrhosis received acute administration of vapreotide. RESULTS: Blood flow of para-esophageal varices could not be measured. SRS blood flow was correlated with the mesenteric percentage of portosystemic shunts (r = 0.74, P < 0.05), splenic percentage of portosystemic shunts (r = 0.54, P < 0.05) and estimated portosystemic blood flow (r = 0.91, P < 0.01). Splenorenal shunt blood flow was 6 to 12 times higher in portal hypertensive rats, e.g., in portal vein ligated rats: 2.8 +/- 2.7 vs 0.3 +/- 0.1 mL.min-1 in sham rats (P < 0.01), and was similar in the different cirrhosis models but was higher in portal vein ligated rats than in cirrhotic rats (1.2 +/- 0.7 vs 0.6 +/- 0.6 mL.min-1.100 g-1, P = 0.05). Octreotide significantly decreased splenorenal shunt blood flow: -23 +/- 20% (P < 0.01) vs -6 +/- 8% (not significant) in placebo rats. The variation of splenorenal shunt blood flow after vapreotide was significant but not that of the splenic percentage of portosystemic shunts compared to placebo. CONCLUSIONS: The splenorenal shunt is the main portosystemic shunt in rats. The measurement of splenorenal shunt blood flow is easy, accurate and reproducible and should replace the traditional measurement of the percentage of portosystemic shunts in pharmacological studies.  相似文献   

11.
BACKGROUND: Microemboli occur commonly during cardiac surgery in adults, and, when present, increase the risk of neuropsychological deficits. Their incidence and significance during correction of congenital heart disease is unknown. The authors hypothesized that microemboli would occur before bypass with right-to-left cardiac shunts and would also occur in large numbers when the aortic crossclamp was released in children during repair of congenital heart defects. METHODS: In 25 children studied with carotid artery Doppler, embolic signals were counted and timed in relation to 13 intraoperative events. Patients were classified as either at high risk (obligate right-to-left shunt or uncorrected transposition of the great arteries) or at low risk (net left-to-right shunt or simple obstructive lesions) for paradoxical (venous to arterial) emboli. RESULTS: The median number of emboli detected was 122 (range, 2-2,664). Forty-two percent of all emboli were detected within 3 min of release of the aortic crossclamp. The high-risk group had significantly more emboli (median, 66; range, 0-116) during the time interval before cardiopulmonary bypass than did the low-risk group (median, 8; range, 0-73), with P < 0.01. There was no significant difference between the high- and low-risk groups in the total number of emboli detected. There was no apparent association between number of emboli and gross neurologic deficits. CONCLUSIONS: Microemboli can be detected in the carotid arteries of children undergoing repair of congenital heart disease and are especially prevalent immediately after release of the aortic crossclamp. The role of emboli in causing neurologic injury in children undergoing repair of congenital heart disease remains to be determined.  相似文献   

12.
Recent studies suggest good prospective accuracy for two-dimensional echocardiographic imaging of ventricular septal defects (VSD). We obtained two-dimensional images with high-frequency, high-resolution scanners from 36 patients proved by cardiac catheterization to have perimembranous VSD. In 20 patients, the VSD was an isolated lesion and in 16 it was associated with other forms of heart disease. VSDs were imaged in long-axis, apical four-chamber and subcostal echocardiographic views. The smallest VSD imaged was 2 mm in diameter on echo; the largest, 23 mm. The imaged size of VSDs was larger at end-diastole than at end-systole by paired t test on all views (all p less than 0.005). VSD size also varied between views, with no predictive relationship except between apical and subcostal four-chamber views in diastole (r = 0.71, p less than 0.005). This agreed with qualitative direct observations of an ellipsoid or irregularly shaped VSD in operated patients. Echocardiographically measured VSD size normalized for either aortic root size or for patient weight could be used to separate isolated VSDs with large shunts (Qp/Qs greater than 2:1) from those with small shunts. Review of 250 two-dimensional echocardiographic studies from patients proved not to have a VSD revealed 28 planes of imaging with false-positive VSD. None of the false-positive VSDs was imaged consistently on all views. Additionally, a "T" artifact (broadening of septal edges around a VSD) has been found to be a reliable marker of true VSD imaging. To best quantify VSD size and to avoid false-positive diagnoses, it is necessary to use multiple views and to consider the marked changes in VSD size that occur between diastole and systole.  相似文献   

13.
The ratio of pulmonary to systemic vascular resistance (Rp/Rs) largely determines the amount of left-to-right shunting and pulmonary to systemic flow rat (Qp/Qs) in the presence of a large isolated ventricular septal defect. The possibility that pharmacologic reduction of systemic vascular resistance with alpha-adrenergic receptor blockade or beta-adrenergic receptor stimulation would increase the ratio Rp/Rs, and therefore reduce the ratio Qp/Qs, was studied in dogs in which ventricular septal defects had been surgically created. Administration of phentolamine and phenoxybenzamine caused a 42% reduction in Rs and no reduction in Rp. Qs was unchanged and Qp declined by 24% and the ratio Qp/Qs fell by 32%. Infusion of the beta-adrenergic receptor stimulant isoproterenol also reduced Qp/Qs. However, this was accomplished as a result of an increase in Qs and at the expense of an increase in heart rate. As a decline in the ratio Qp/Qs has been shown to be beneficial to patients with large left-to-right shunts, pharmacologic reduction of systemic vascular resistance may prove to be helpful in treating congestive heart failure in those patients with large left-to-right shunts at the ventricular level who are refractory to the usual decongestive measures.  相似文献   

14.
OBJECTIVE: Forty percent of standard cerebrospinal fluid shunts implanted for the treatment of pediatric hydrocephalus fail within the first year. Two new shunt valves designed to limit excess flow, particularly in upright positions, were studied to compare treatment failure rates with those for standard differential-pressure valves. METHODS: Three hundred-forty-four hydrocephalic children (age, birth to 18 yr) undergoing their first cerebrospinal fluid shunt insertion were randomized at 12 North American or European pediatric neurosurgical centers. Patients received one of three valves, i.e., a standard differential-pressure valve; a Delta valve (Medtronic PS Medical, Goleta, CA), which contains a siphon-control component designed to reduce siphoning in upright positions; or an Orbis-Sigma valve (Cordis, Miami, FL), with a variable-resistance, flow-limiting component. Patients were monitored for a minimum of 1 year. Endpoints were defined as shunt failure resulting from shunt obstruction, overdrainage, loculations of the cerebral ventricles, or infection. Outcome events were assessed by blinded independent case review. RESULTS: One hundred-fifty patients reached an endpoint; shunt obstruction occurred in 108 (31.4%), overdrainage in 12 (3.5%), loculated ventricles in 2 (0.6%), and infection in 28 (8.1%). Sixty-one percent were shunt failure-free at 1 year and 47% at 2 years, with a median shunt failure-free duration of 656 days. There was no difference in shunt failure-free duration among the three valves (P = 0.24). CONCLUSION: Cerebrospinal fluid shunt failure, predominantly from shunt obstruction and infection, remains a persistent problem in pediatric hydrocephalus. Two new valve designs did not significantly affect shunt failure rates.  相似文献   

15.
We present a case of a 19-year old female with systemic pulmonary artery (PA) pressure due to a congenital ventricular septal defect (VSD) and atrial septal defect (ASD). She was pink at rest and cyanotic on exercise. Lung biopsy revealed grade IV pulmonary vascular changes. As a preliminary step PA was banded to increase right-to-left shunt and decrease aortic (Ao) saturation with consequent decrease in PA saturation. After one year, when she was no longer cyanotic, even on exercise, lung biopsy revealed total regression of pulmonary vascular changes. As a definitive procedure VSD and ASD were closed and PA was debanded. Cardiac catheterization one week postoperatively showed PA pressure to be 50% of systemic pressure. We postulate that reversal of pulmonary vascular changes were due to lowered PA saturation. We further believe that lower PA pressure could have contributed to this regression of pulmonary vascular changes. We performed the same procedure in six more patients with similar positive clinical response. This new concept brings renewed hope to many children who otherwise are candidates for heart lung transplantation.  相似文献   

16.
OBJECTIVE: We assessed the feasibility of contrast-enhanced color Doppler, power Doppler, and spectral duplex sonography for visualization and quantification of flow through transjugular intrahepatic portosystemic shunts (TIPS) in patients in whom the baseline sonographic evaluation was unsatisfactory. SUBJECTS AND METHODS: Thirty-three patients underwent color Doppler, power Doppler, and spectral duplex sonography after TIPS insertion or before TIPS revision (mean time interval +/- SD, 1 +/- 1 day). All sonograms were obtained before and after patients received echo-enhancing contrast material. Sonography was evaluated with regard to presence or absence of flow in the mid portion, portal segment, and hepatic segment of the shunt. The maximal peak velocity was measured in the mid portion of the shunt. For identifying and quantifying stenoses, the percentage of luminal diameter reduction was calculated at the tightest part of the shunt. Shunt angiography and measurements of portosystemic pressure gradients were independently evaluated and compared with the sonographic findings. RESULTS: Flow visualization on unenhanced color Doppler sonography was significantly improved through the use of power Doppler sonography and contrast-enhanced color Doppler and power Doppler sonography (p < .01). Between contrast-enhanced power Doppler and contrast-enhanced color Doppler sonography, a significant difference was found in the portal and hepatic segments (p < .05). All shunt stenoses (n = 8) and occlusions (n = 3) were revealed by power Doppler sonography, whereas color Doppler sonography failed to reveal six of eight stenoses. Compared with unenhanced sonography, the quality of spectral duplex sonography was improved in eight patients after contrast enhancement (p < .05). Maximal peak velocity ranged from 54 to 252 cm/sec (mean +/- SD, 132.7 +/- 52.1 cm/sec) in normal shunts and from 24.5 to 70.0 cm/sec (mean +/- SD, 45.0 +/- 18.9 cm/sec) in stenosed shunts. No correlation was found between maximal peak velocity and portosystemic pressure gradients (r = .28). CONCLUSION: Unenhanced power Doppler and contrast-enhanced color and power Doppler sonography can be helpful in the assessment of TIPS status in patients who previously underwent unsatisfactory sonography. These techniques may allow anatomic evaluation and quantification of shunt stenosis in most patients. Contrast enhancement may also considerably improve the quality of spectral duplex sonography.  相似文献   

17.
From May 1991 to August 1994, we performed transcatheter closure of patent ductus arteriosus with Rashkind umbrella system in 25 patients. In one, the device had embolism, to the right pulmonary artery and was operated 24 hs afterwards without complications. Seven had residual shunts, two had subsequent surgery, two are being followed (one for mild and one for moderate residual shunt). In the other three cases we inserted a second device. We used a 12 mm device in two cases and a 17 mm device in the other. Two cases had total occlusion 24 hrs after and in one had mild residual shunt without clinical repercussion. There were no complications. All had electrocardiographic and clinical improvement, take no medication, and their cardiomegaly had decreased (Cardiac index pre 61 vs post 54%). In conclusion the insertion of a second device is safe and effective alternative for residual shunt after first Rashkind occluder.  相似文献   

18.
Atrial septal defect (ASD) is one of the most common congenital cardiac anomalies encountered in adulthood. The evaluation of the pulmonary hypertension in ASD is clinically important for operative indication and prognosis. The pulmonary vasculature in chest radiographs in patients with ASD is characterized as dilatation of the central pulmonary arteries and increase of the peripheral pulmonary vessels in patients without pulmonary arterial hypertension (PH) and constriction of the peripheral pulmonary arteries in those with pulmonary hypertension. While the dilatation of the main pulmonary artery occurs in the patients both with and without pulmonary hypertension, its precise radiographic evaluation with regard to the morphological and hemodynamic change of the right ventricle and pulmonary arteries has not been reported. This study was to determine if the contour of the main pulmonary artery segment of the cardiac silhouette in the conventional frontal chest radiograph could be used 1) as indicators of PH or raised right ventricular pressure and 2) as a reliable base for evaluation of the size of the right ventricule (RV) in ASD. The intersection of the line (line A) drawn tangentially to the lateral lower margin of the main pulmonary artery segment to the horizontal line at the left hemidiaphragm is closely related to the apex of RV as measured by right ventricular angiography in supine position. The ratios of the distance of the intersection from the midline of the frontal chest radiograph to the internal diameter of the left hemithorax in normal subjects were 0.50 +/- 0.08 (mean +/- standard deviation) for male and 0.54 +/- 0.09 for female. The ratio increased with increasing left-to-right shunt [0.59(Qp/QS < 2), and 0.71 (Qp/QS > 2)] and shows a tendency of decrease with raised right ventricular systolic pressure (0.52-0.64 in normal subjects and patients with mild raised right ventricular systolic pressure and 0.43 in patients with severe raised right ventricular systolic pressure). The measurement of the angle of the line A from the vertical line tends to show increasing decrease with raised pulmonary arterial and right ventricular systolic pressure (20.1 degrees +/- 4.9 in mild PH and 10.3 degrees +/- 4.1 in moderate to severe PH). The decrease of the angle of the line A to the vertical line was well correlated with conventional radiographic criteria of the right and left central pulmonary arteries of PH.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

19.
Pulsed Doppler echocardiographic and hemodynamic examinations were performed in 31 patients (mean age 17.8 years) with isolated ventricular septal defect (VSD). Three groups were studied: group I (n = 6) patients had severe pulmonary vascular obstructive disease (PVOD); group II (n = 12) patients had pulmonary hypertension (PH) without severe PVOD; group III (n = 13) patients had no PH. Bidirectional shunting was detected in 9 VSD patients (6 in group I and 3 in group II). Patients with low to moderately elevated right ventricular pressures demonstrated left-to-right shunting across the defect throughout the cardiac cycle. When systolic pressure in the right ventricle reached approximately 60% of the left ventricular pressure, right-to-left shunting occurred across the defect during early and mid diastole. However, in patients with Eisenmenger syndrome (group I) the right-to-left shunting occurred during late systole with continuation during the early and mid diastolic period. The earlier occurrence of right-to-left shunting (index < 0.5 second) signifies the presence of severe PVOD.  相似文献   

20.
We present a 74-year-old female who showed a large left-to-right shunt through a small atrial septal defect presumably due to diastolic dysfunction of the left ventricle caused by the progression of aortic stenosis. Accordingly, elderly patients with even small atrial septal defect should be followed carefully, since diastolic dysfunction of the acquired left ventricular disorder could increase the left-to-right shunt.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号