首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 36 毫秒
1.
Measurement of fine particle emission from combustion sources is important to understand their health effects, and to develop emissions regulations. Dilution sampling is the most commonly used technique to measure particle number distribution because it simulates the mixing and cooling of combustion exhaust with atmospheric air, which drives nucleation and condensation of semi volatile material. Experiments suggest that the measured size distribution is dependent on the dilution ratio used and the tunnel design. In the present work, computational analysis using a large-eddy-simulation (LES) based model is performed to investigate the effect of tunnel flow and geometric parameters on H2SO4-H2O binary nucleation inside dilution tunnels. Model predictions suggest that the experimental trends are likely due to differences in the intensity of turbulent mixing inside the tunnels. It is found that the interaction of dilution air and combustion exhaust in the mixing layer greatly impacts the extent of nucleation. In general, a cross-flow interaction with enhanced turbulent mixing leads to greater number of nucleation-mode particles than an axial-flow interaction of combustion sample and dilution air.

Copyright 2014 American Association for Aerosol Research  相似文献   


2.
Traffic-related pollutants are an ever-growing concern. However, the composition of particle emissions from new vehicle technologies using relevant current and prospective fuel blends is not known. This study tested four current and up-and-coming vehicle technologies with nine fuel blends with various concentrations of ethanol and iso-butanol. Vehicles were driven on both the federal test procedure (FTP) and the unified cycle (UC). Additional tests were conducted under steady-state speed conditions. The vehicle technologies include spray-guided gasoline direct injection (SG-GDI), wall-guided gasoline direct injection (WG-GDI), port-fuel injection flex fuel vehicle (PFI-FFV), and a wall-guided GDI-FFV. The fuels consisted of 10–83% ethanol and 16–55% iso-butanol in gasoline. The composition of soot, water-insoluble mass (WIM), water-soluble organic mass, and water-insoluble organic mass (WIOM), and OM was measured. The majority of emissions over FTP and UC were water-insoluble (>70%), and WIOM contributes mostly to OM. PFIs have lower soot and particulate matter (PM) emissions in comparison to the WG-GDI technology even while increasing the renewable fuel content. SG-GDI technology, which has not penetrated the market, show promise as soot and PM emissions are comparable to PFI vehicles while preserving the GDI fuel economy benefits. The WIM fraction in GDI-FFV consistently increased with increasing ethanol concentration. Lastly, the impact of the future vehicle emissions and traffic pollutants is discussed. SG-GDI technology is found to be a promising sustainable technology to enhance fuel economy and also reduce PM, soot, and WIM emissions.

Copyright © 2017 American Association for Aerosol Research  相似文献   


3.
Aerosol instruments provide more informative engine exhaust particulate matter (PM) data than the gravimetric filter and solid particle number methods prescribed by regulations. Yet their lack of conformity to the regulatory methods can limit their acceptance for vehicle development. This article examines the ability of the Dekati Mass Monitor (DMM), Engine Exhaust Particle Sizer (EEPS), and Micro Soot Sensor (MSS) to measure PM2.5 mass and solid particle number relative to current motor vehicle PM emissions standards. Simultaneous PM measurements are made by these three instruments and the two regulatory methods for 50 tests of six gasoline direct injection and two port fuel injection vehicles over the U.S. Federal Test Procedure. DMM and EEPS determinations of PM mass correlate well to gravimetric values (regression slopes of 1.06 ± 0.04 and 0.98 ± 0.08) down to a few mg/mile, below which filter weighing variability becomes problematic. The MSS exhibits a lower slope of 0.79 ± 0.03 consistent with it measuring the soot fraction, rather than total PM. At emissions rates above ~1013 particles/mile, solid particle number determined from DMM and EEPS data correlates respectably with, but overestimates the regulatory method (regression slopes are 1.7 ± 0.1 and 1.4 ± 0.15, respectively). Below this emissions rate, the correlation degrades. EEPS estimates of PM mass are significantly improved with the recent soot optimized inversion algorithm (slope improves from 0.45 to 0.98). While they cannot replace filters and solid particle counting, the present study suggests that these instruments can be used as more informative surrogates during motor vehicle development.

© 2016 Ford Motor Company  相似文献   


4.
Accurate exposure assessments are needed to evaluate health hazards caused by airborne microorganisms and require air samplers that efficiently capture representative samples. This highlights the need for samplers with well-defined performance characteristics. While generic aerosol performance measurements are fundamental to evaluate/compare samplers, the added complexity caused by the diversity of microorganisms, especially in combination with cultivation-based analysis methods, may render such measurements inadequate to assess suitability for bioaerosols. Specific performance measurements that take into account the end-to-end sampling process, targeted bioaerosol and analysis method could help guide selection of air samplers.

Nine different samplers (impactors/impingers/cyclones/ electrostatic precipitators/filtration samplers) were subjected to comparative performance testing in this work. Their end-to-end cultivation-based biological sampling efficiencies (BSEs) and PCR-/microscopy-based physical sampling efficiencies (PSEs) relative to a reference sampler (BioSampler) were determined for gram-negative and gram-positive vegetative bacteria, bacterial spores, and viruses.

Significant differences were revealed among the samplers and shown to depend on the bioaerosol's stress–sensitivity and particle size. Samplers employing dry collection had lower BSEs for stress-sensitive bioaerosols than wet collection methods, while nonfilter-based samplers showed reduced PSEs for 1 μm compared to 4 μm bioaerosols. Several samplers were shown to underestimate bioaerosol concentration levels relative to the BioSampler due to having lower sampling efficiencies, although they generally obtained samples that were more concentrated due to having higher concentration factors.

Our work may help increase user awareness about important performance criteria for bioaerosol sampling, which could contribute to methodological harmonization/standardization and result in more reliable exposure assessments for airborne pathogens and other bioaerosols of interest.

Copyright 2014 American Association for Aerosol Research  相似文献   


5.
A novel air sampling monitor was developed for near-continuous (i.e., 2-h time resolution) measurement of iron (Fe), manganese (Mn), and chromium (Cr) concentrations in ambient coarse particulate matter (PM) (i.e., PM10–2.5). The developed monitor consists of two modules: (1) the coarse PM collection module, utilizing two virtual impactors (VIs) connected to a modified BioSampler to collect ambient coarse PM into aqueous slurry samples; (2) the metal concentration measurement module, which quantifies the light absorption of colored complexes formed through the reactions between the soluble and solubilized target metals and pertinent analytical reagents in the collected slurries using a micro volume flow cell (MVFC) coupled with UV/VIS spectrophotometry. The developed monitor was deployed in the field for continuous ambient PM collection and measurements from January to April 2016 to evaluate its performance and reliability. Overall, the developed monitor could achieve accurate and reliable measurements of the trace metals Fe, Mn, and Cr over long sampling periods, based on the agreement between the metal concentrations measured via this online monitor and off-line parallel measurements obtained using filter samplers. Based on our results, it can be concluded that the developed monitor is a promising technology for near-continuous measurements of metal concentrations in ambient coarse PM. Moreover, this monitor can be readily configured to measure the speciation (i.e., water-soluble portion as well as specific oxidation states) of these metal species. These unique abilities are essential tools in investigations of sources and atmospheric processes influencing the concentrations of these redox-active metals in coarse PM.

Copyright © 2016 American Association for Aerosol Research  相似文献   


6.
Six distillation column models have been used in studies of the usefulness of the Inverse Nyquist Array (INA) method for design of dual composition control for distillation. Five of the column models are experimental, one describing an industrial column, the others four pilot plants. One column model is obtained by modeling from first principles.

The control strategies investigated and compared are multiloop SISO, 2-way decoupling and l-way decoupling. The control variables are the standard ones, i.e. reflux flow and boilup.

In most of the cases INA has been found to be a useful tool for design of the loops and for comparison of the different control approaches. INA has also been found to be useful for simultaneous tuning of the decouplers and the feedback controllers.

For 2-way decoupling the criterion to minimize interaction at the critical frequency for each primary feedback loop has been found useful in most, but not all, cases. The scheme can be designed by pure gains in the decouplers and there is no reason to introduce dynamics into the decouplers—the systems studied are already sufficiently rich in dynamics.

INA has been found to be a suitable vehicle for the choice between the two possible l-way decoupling schemes.

With the design approach taken, l-way decoupling has been found to provide considerably better control quality than 2-way decoupling in two of the six systems, the differences in control quality being small in the other cases.

The effect of model mismatching on the results, caused e.g. by process nonlinearities, is discussed and simple rules to decrease the parameter sensitivity for 2-way decoupling schemes are given. When model mismatching is considered, the advantage of l-way decoupling over 2-way decoupling seems to increase.

One deficiency of the INA design as used in this paper is that it does not single out the design which is to be preferred on the grounds of robustness.  相似文献   


7.
The conventional blown process imparts an inherent haze to the product. The percentage of haze varies with certain process variables:

1. Surface irregularities caused by melt flow phenomena

2. Crystallization behavior

3. Melt drawing phenomena in certain types of polyethylene  相似文献   


8.
A novel monitor for online, in situ measurement of copper (Cu) in ambient fine and ultrafine particulate matter (PM) was developed based on a recent published high flow rate aerosol-into-liquid collector. This aerosol-into-liquid collector operates at 200 L/min flow and collects particles directly as highly concentrated slurry samples. The Cu concentration in slurry samples is subsequently determined by a cupric ion selective electrode (ISE). Laboratory tests were conducted to evaluate the performance of the cupric ISE. The calibration curve of the cupric ISE was determined using Cu(NO3)2 standard solutions prepared by serial dilution. As part of the evaluation, the effects of ionic strength, temperature and pH of the aerosol slurry sample on the cupric ISE measurement were also evaluated. The Cu measurement system performance was evaluated by collecting and measuring samples of lab-generated Cu(NO3)2 aerosols with known mass concentration. Overall, very good agreement between the theoretical and measured Cu concentrations was obtained, corroborating the excellent high overall collection efficiency and measurement accuracy of the Cu measurement system. Field evaluations of the online Cu monitor demonstrated very good agreement for total and water-soluble Cu concentrations with measurements performed by inductively coupled plasma mass spectrometry (ICP-MS), suggesting that interferences from other components of particulate matter are minimal under real world sampling conditions. Moreover, the field tests indicated that the new online Cu monitor could achieve near-continuous collection and measurements (at 2–4 h intervals) for at least 4 to 7 days without any obvious shortcomings in its operation. Both laboratory and field evaluations of the online Cu monitor indicate that it is an effective and valuable technology for PM collection and characterization of Cu in ambient aerosols and provides the foundation for the wider use of ISE for metal analysis and speciation of aerosols.

Copyright 2014 American Association for Aerosol Research  相似文献   


9.
The theory of gas absorption accompanied by fast pseudo-fast order reaction which considered dependences of diffusivity, kinetic constant and Henry's law constant on absolute temperature and ionic strength was used to obtain values of effective interfacial areas and mass transfer coefficients in gas and liquid phase.

Experimental measurement of carbon dioxide absorption from mixture with air was performed in a pilot-plant column with expanded metal sheet packing irrigated with sodium hydroxide solution.

Resulting liquid and gas-side mass transfer coefficients are compared with values obtained from physical Absorption measurement of carbon dioxide into water and with measurement of gas-side mass transfer coefficient for sulphur dioxide in the same column.

The differences between determined values are discussed.  相似文献   


10.
Air stripping towers have been recommended for the removal of volatile organic compounds (VOCs) in drinking water supply and industrial waste treatment systems. This technique removes VOCs economically in the liquid phase. It can, however, create adverse secondary environmental impacts by removing VOCs from the water and discharging them to the air.

A commonly proposed method for controlling .VOC emissions is filtration of the off-gas through adsorption of the stripped organics in the off-gas by granular activated carbon. The high incremental cost of this alternative has produced an interest in alternative control technologies.

One alternative currently available is based on short wavelength ultraviolet (UV) radiation. This technique combines the effects of ozone generation, free radical formation and photolysis of the contaminants to effectively control the VOC emissions. This technique is known as Advanced Photo Oxidation (APO)R.

The cost for APO is $0.27/m3 for a 3.8 m3/hr contaminated water system. A system of this size is adequate for a groundwater decontamination project where a moderate length of time is available for restoration of the site. The cost of a conventional air stripping tower with Granular Activated Carbon (GAC) adsorption emissions control in this size range would be $0.40 to $0.45/m3 (J.M. Montgomery, 1986).

Additional testing will be required to fully develop design guidelines for different contaminants and larger systems. Another area for additional technical documentation is the application of this technique to the liquid phase oxidation of VOCs.  相似文献   


11.
The aerodynamic lens system of the Aerodyne Aerosol Mass Spectrometer (AMS) was analyzed using the Aerodynamic Lens Calculator. Using this tool, key loss mechanisms were identified, and a new lens design that can extend the transmission of particulate matter up to 2.5 μm in diameter (PM2.5) was proposed. The new lens was fabricated and experimentally characterized. Test results indicate that this modification to the AMS lens can significantly improve the transmission of large sized particles, successfully achieving a high transmission efficiency up to PM2.5 range.

© 2016 American Association for Aerosol Research  相似文献   


12.
The Fifth Annual Conference on Flame Retardancy was held May 24–26, 1994, at the Ramada Plaza Hotel, Stamford, Connecticut, USA. The conference was organized by Business Communications Company, Inc., Norwalk, Connecticut (Company President, Mr. Louis Naturman; Conference Coordinator, Mrs. Sharon D. Faust). New materials (polymers, blends, composites), their applications, industry developments, and markets were considered. Specifically, the most important topics were:

Introduction of new technological achievements and development in the field of flame retardancy (FR)

Review of the current state of science and technology in FR

Review of applications and markets for FR products

Presentation of recent developments in local and global standardization and in testing technology

Discussion of toxicity and environmental issues

Provision of a unique opportunity for newcomers to FR research technology and marketing to become acquainted with the FR field in all its aspects

Discussion of halogen-based and non-halogen-based flame retardant chemicals, syngergism, intumescence, FR mechanisms, modeling, flame parameters, inherently FR polymers, and polymer blends  相似文献   


13.
To obtain reliable mass concentrations of solid particulate matter (PM) in the exhaust emissions from engines using optical instruments, it is essential that the solid PM used for instrument calibration has similar optical properties to the solid PM emitted from the engines being tested. The solid PM emitted from combustion engines is predominantly soot. The optical properties of soot are dictated by its chemical structure, size, and morphology. In this work, the chemical bond structure, primary-particle diameters, aggregate sizes, and morphological parameters of the soot emitted from two laboratory soot generators, widely used for calibrating instruments, are compared to those of soot emitted from three aircraft turbine engines using Raman spectroscopy and transmission electron microscopy. The Raman spectral properties, size, and morphology of soot emitted from aircraft engines are distinctly different from the properties of soot emitted from the soot generators operating under globally near-stoichiometric and fuel-rich conditions. These differences can be attributed to the variations in the size and orientation of the graphitic crystallites, amorphous-carbon content, amount of polyacetylene compounds, deposition of organic material, and extent of oxidation. Conversely, general agreement is observed between the chemical structure, size, and morphology of soot emitted from aircraft engines and the soot emitted from the soot generators operating at globally fuel-lean conditions. The findings of this investigation can be useful for identifying suitable soot particles for the calibration of instruments to measure the mass concentration of solid PM emissions from engines, and for other types of soot.

Copyright © 2017 Crown Copyright  相似文献   


14.
We measured real-time and integrated PM2.5 inside eight occupied single-family homes in Fresno, California to evaluate how turbulent air mixing and pollutant removal caused by a filter-based air purifier influences the levels of fine particles in everyday indoor environments. In each home, we used a real-time monitor to log PM2.5 levels every 5 min over 12 weeks during which air purifiers were operating, except for a designed 3-day shutdown period for baseline measurements. We assessed how the operation of air purifiers changed the patterns of the frequency distributions for short-term (5 min) concentrations, which included spikes produced by sporadic indoor activities or emissions. This allowed us to examine the reduction effectiveness of air purifiers on concentrations of both recently emitted and well-mixed background aerosols. We observed a systematic change in the 5-min PM2.5 distributions in different homes—while air purifiers reduced 96% of the 5-min concentrations, they increased the magnitudes of the top 4%, representing transient concentration peaks. This phenomenon is consistent with what would be theoretically expected based on passive scalar turbulence in fluid physics. We also collected gravimetric filter samples for PM2.5 composition, finding mean reductions of the long-term (2–5 days) concentrations of 29%–37% for indoor PM2.5 and endotoxin. A less significant reduction (19%–26%) was seen for Pb (Lead).

© 2016 American Association for Aerosol Research  相似文献   


15.
A scanning mobility particle sizer was used to determine the size, number, and mass concentration of particle emissions from an ethanol-fueled homogeneous charge compression ignition (HCCI) engine. Semi-volatile particle composition was characterized using tandem differential mobility analysis (TDMA). Variable temperature thermal conditioning was used to gain insight into particle volatility and a catalytic stripper was used to determine the solid particle distribution. Four engine conditions were evaluated, including low to moderate range loads and motoring (deceleration, coasting). Results indicated that aerosol from a fully premixed HCCI engine under firing conditions is formed almost entirely via nucleation of semi-volatile material originating from the lubricating oil. TDMA analysis indicated 98% of total particle volume evaporated below 100°C. Results pointed towards homogeneous nucleation of precursors derived from the organic species in the lubricating oil, possibly in combination with a sulfur species. The motoring condition, with no fuel injected, exhibited the highest number and mass concentrations. During motoring, there was poor sealing leading to increased atomization of oil and associated ash emissions. Emissions were lower during firing with better sealing and much less atomization, but evaporation of the most volatile fractions of the lubricating oil still led to significant PM emissions consisting of nearly entirely semi-volatile particles containing very little ash.

© 2017 American Association for Aerosol Research  相似文献   


16.
The article presents a mathematical model for calculation of nonstationary hydraulic and separation processes in a gas centrifuge (GC) cascade for separation of multicomponent isotope mixtures. The model has been applied to calculate the parameters of nonstationary processes in a GC cascade for separation of krypton, germanium and tungsten isotopes. As a result, the specifics of the excess holdup distribution along the cascade stages has been identified, and variations of the isotope concentrations in a nonstationary process have been revealed. The data obtained show that the proposed mathematical model is able to adequately describe nonstationary hydraulic processes in GC cascades for separation of multicomponent isotope mixtures.

Highlights:

Mathematical model of cascade for separation of multicomponent isotope mixture has been developed.

The model verification has been done.

The isotope transient regularities into cascade during nonstationary processes has been identified.  相似文献   


17.
Fibrous filters are commonly used for aerosol purification and sampling. The filtration efficiency has been extensively studied using standard aerosol generators, yet the literature on experimental data and theoretical study concerning the filtration of agglomerates from real engines remains scarce. A filtration efficiency test system was developed to determine the filtration efficiency of two types of filters (uncoated and fluorocarbon coated) loaded by particulate matter (PM) emissions from a gasoline direct injection (GDI) engine. The experimental results showed that the filtration efficiency in terms of PM mass and number increased over time for both types of filters. The fractional efficiency (penetration efficiency) curves for the test fibrous filters rendered a U-shaped curve for particle sizes from 70 to 500 nm, and the most penetrating particulate size (MPPS) decreased over time. A small fraction of accumulation mode particles with the size between 70 nm to 500 nm penetrated the filters while almost all nucleation mode particles with the size below 50 nm were captured by the filters. The filtration efficiency derived from an empirical model based on classical single-fiber theory for laden filters generally agreed with the experimental data for the first 500 s, but suffered a significant deviation by approximately one order of magnitude at 948 s. A better estimate of the filtration efficiency trend with the maximum deviation of about 20% (except for large particles at the high end of the measurement spectra) was obtained by using a revised model which incorporates the effects of the increase in filter solidity, local velocity, dynamic shape factor and effective total length of fibers during the filtration process.

© 2017 American Association for Aerosol Research  相似文献   


18.
19.
The estimation of air velocity distributions and particle trajectories is inevitable to analyse the mechanism of classification, but the direct measurement of il is extremely difficult.

The authors, here report three dimensional air velocity distributions within the inside drum of model Sturtevant-type air classifier measured by a spherical five-holed Pitot-lube, and also two dimensional particle ejecting velocities on a model distributor determined by photography.

Using those results, the cut size calculated from particle trajectories in the classifier is compared with the experimental results and theoretical values.  相似文献   


20.
Four N-donors (PHDA, ATPH, APHO, and MTAN) containing NH2 were used to extract Hg(II), Cd(II), and Pb(II). Their extraction capacity was determined by measurement of percentage extraction.

The chelates extract these metals differently: for example, efficiency of ATPH was the highest for Hg(II) compared to PHDA, APHO, and MTAN.

The extraction efficiency was found to depend on: donor atom hardness, chelate total hardness, metal: chelate mole ratio and substituent’s electronic effects. Among all, total hardness and chelate stability are key factors and molecule of small (EHOMOELUMO) is more reactive, where extraction efficiency increases as molecular stability decreases.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏