共查询到20条相似文献,搜索用时 93 毫秒
1.
2.
《电气开关》2020,(1)
锁相环(Phase-Locked Loop,PLL)作为逆变器并网运行的核心技术之一,为了应对电网在谐波畸变的情况下而形成的非理想电压,提高单相并网逆变器锁相环的工作性能,本文提出了一种基于前置滑动平均滤波器(Moving Average Filer,MAF)的单相锁相环。该单相锁相环采用二阶广义积分(Second Order Generalized Integrator,SOGI)算法作为单相锁相环的正交信号发生器(Orthogonal Signal Generation,OSG),并在其引入一个简易的锁频环(Frequency-Locked Loop,FLL)以自适应电网频率;最后在同步旋转坐标系下捕获电网电压的频率和相位信息,实现无静差同步跟踪。仿真结果表明,本文所提出的单相锁相环结构在谐波畸变的电网环境下,能准确快速地跟踪电网基波电压相位,验证了该方法的可行性。 相似文献
3.
传统的硬件锁相方法在畸变电压条件下会得到错误的相位信息。这里提出了一种基于PI控制的软件锁相环,通过同步旋转坐标跟踪原理,达到相位锁定的目的。在波形畸变、相位突变等条件下,都具有良好的抗干扰能力,能以较快速度、较高精度实现锁相。仿真实验验证了该方法的正确性。 相似文献
4.
锁相环技术是并网变流器的核心技术之一。针对传统单相同步旋转坐标系锁相环在畸变电网下锁相精度差的问题,提出一种基于离散傅里叶变换(DFT)的高精度锁相环技术。基于DFT的锁相技术的核心问题是如何准确获取电网频率,将DFT和单相同步旋转坐标系锁相环相结合,利用DFT的优异选择性滤波性能和相角变换性质,从畸变电网信号中准确提取基波和生成虚拟正交信号,在同步旋转坐标系提取电网频率,实现DFT的频率自适应,最终无静差、高精度跟踪电网相位。仿真和实验结果表明,所提出的锁相环对电网电压的畸变谐波、直流偏置误差和电网频率脉动等有很好的适应性,在各种电网条件下,均能准确地跟踪电网电压相位,验证了该锁相方法的有效性和优越性。 相似文献
5.
对于并网型电能质量治理设备,如有源电力滤波器(APF),为了实现对电能质量的检测与治理功能,需要对三相电压基波的正负序进行快速准确提取。当电网电压发生不对称、畸变等情况时,能否快速准确获得基波电压的频率和相位信息将会大大影响电能质量治理设备运行性能。文中依据同步旋转坐标变换理论,采用双dq变换方法,通过低通滤波器(LPF)处理,实现对基波电压的正负序提取,在此基础上引入负反馈控制理论实现锁相环功能。依据此理论使用FPGA实现基波电压正负序提取及锁相环功能,经测试表明文中所设计的系统能够在三相电压出现不对称、畸变等情况时,快速准确实现基波电压正负序提取、以及基波频率和相位的锁定,能够满足有源电力滤波器对于电压频率、相位实时检测与设备控制保护的使用需求。 相似文献
6.
7.
8.
同步相位与瞬时对称分量的检测新方法 总被引:4,自引:1,他引:3
电网不对称故障时,快速、准确地检测同步相位和对称分量,是基于电压源逆变器的灵活交流输电系统(FACTS)装置实现控制与保护的关键问题之一。在分析传统三相锁相环工作原理和负序分量影响锁相环(PLL)检测性能的基础上,设计了一种同步相位与对称分量的一体化实时检测新方法。该方法在正负序同步坐标系下采用电压前馈补偿实现对称分量的检测,用测得的基波正序电压q轴分量作为锁相环的输入,用锁相环的输出相位作为同步坐标变换的参考相位。并分析了该方法实现的机理,给出了检测电路的实现框图,同时进行了实验验证。结果表明,该方法既能在电网电压不对称时准确检测同步相位和对称分量,又能消除交流系统频率变化对检测同步相位和对称分量的影响。 相似文献
9.
10.
11.
畸变电压下单相电路谐波和无功电流综合检测方法 总被引:2,自引:0,他引:2
在现有单相电路基波电流分离法基础上,分析了锁相环相位检测误差和畸变电压对谐波和无功电流检测的影响,得出由锁相环及畸变电压引起的相位检测误差不影响谐波电流的检测,但对谐波和无功电流的综合检测以及直流侧电压调整有影响的结论.提出了一种谐波和无功电流综合检测新方法,采用无锁相环、提取功率角的方式,实现了畸变电压下单相电路谐波和无功电流的综合检测.仿真结果验证了该检测方法应用于有源电力滤波器中的有效性. 相似文献
12.
13.
14.
Cascaded H-bridge multilevel inverter (CHB-MLI)-based shunt active power filter (SAPF) is one of the finest solutions for power quality improvement in case of medium-voltage distribution sector. Performance of SAPF degrades due to the presence of DC offset and harmonics in the grid voltage since this will result phase angle and frequency error. Therefore, modified single-phase synchronous reference frame theory comprising of advanced PLL is presented in this article. The advanced PLL can track frequency and phase angle accurately even though source voltage is having DCor harmonic content. A detailed mathematical modeling and stability analysis of this PLL is presented using Routh-Hurwitz criteria. A novel systematic design procedure using gravitational search algorithm (GSA) and an Eigen value analysis is proposed for calculating optimal PLL parameters. Closed-loop SAPF control stability is tested using root-locus analysis. An extensive experimental analysis of the proposed control applied to CHB-MLI-based SAPF has been performed under distorted source voltage and non-linear loading conditions to show the effectiveness of the proposed control over recently published work. Source current maintains its sinusoidal shape, properly synchronized with grid voltage and having distortion limit in compliance with IEEE-519 standard irrespective of source voltage conditions during the operation of SAPF. 相似文献
15.
就目前电能质量问题中常见的电压波动(骤升、骤降、闪变、谐波)检测技术进行了探讨。对经典的和目前众多热点研究的电压波动检测技术进行了分析,包括锁相技术中的过零锁相和软件锁相环(SPLL),以及波动特征量检测中的均方根值法、dq0变换法、改进窗口傅里叶变换法及研究最多的小波变换法,并对各种算法的优、缺点和适用范围作了分析、比较。过零锁相即硬件锁相(PLL)由鉴相器、环路滤波器、压控振荡器及分频器组成,其原理和结构较简单,但动态性能较差,且在畸变电压输入时锁相效果变差;软件锁相环是一种基于瞬时无功理论的锁相方式,其结构比较简单、动态响应速度快、能准确地锁定电源电压的基波正序分量,对谐波有很强的抑制作用,一般无需滤波环节。最后,对电压波动检测技术进行了总结。 相似文献
16.
动态电压恢复器是一种新型的电能质量调节装置,它能有效地抑制电网电压波动对敏感负载的影响。针对在电网畸变以及不对称跌落的情况下,动态电压恢复器需要准确地捕获基波电压正序相位。采用了一种双dq变换软件锁相环(DDSRF-PLL),不仅能够快速有效地检测电网电压在对称、不对称、不对称且畸变情况下正序基波电压的相位,为动态电压恢复器提供准确的锁相角,同时也具备较好的动态性能,使动态电压恢复器获得较好的补偿结果。在Matlab/Simulink中建立了带超级电容的动态电压恢复器的仿真模型,仿真结果验证了双dq变换软件锁相在动态电压恢复器的有效性和可行性。 相似文献
17.
一种新型的单相并网系统锁相环 总被引:1,自引:0,他引:1
电网电压的相角、频率对并网逆变器而言是最基本的信息.准确快速地跟踪电网电压是并网控制系统稳定运行的保障.在单相并网逆变器中,常规的过零点检测锁相方法往往对电网电压畸变或扰动敏感,使得锁相环处于不稳定状态,从而导致并网逆变系统性能降低,甚至不能正常工作.针对此问题,分析了基于同步旋转坐标变换的锁相环原理,并将这种锁相策略... 相似文献
18.
19.
20.
电力系统谐波不稳定及相应对策的研究 总被引:2,自引:0,他引:2
近年来在一些工厂、港口发生局部电力不稳定,表现为电压和频率剧烈变化随即停电。该文说明此现象属于谐波不稳定,而产生的原因主要是电力电子装置产生的谐波过大,导致同步锁相失败。该文提出良好的强靭锁相的必要条件是被锁相的电压应处理成三相系统的基频电压分量,同时必须是三相基波的正序分量。为达到正确处理带有谐波三相不平衡的电压,采用“滑动傅里叶方法”和“滑动对称分量法”,可用极少量的计算取出正序基波电压。为串联电力电子设备的锁相,该文展示提取基波电流的方法,也将说明有效地检出谐波的数字方法。 相似文献