共查询到20条相似文献,搜索用时 109 毫秒
1.
2.
3.
准确界定负荷稳定与电压稳定的关系对于完善电力系统电压稳定理论基础有重要意义.利用非线性动力系统稳定理论,定义了负荷稳定,发现负荷失稳的有限性,即在负荷失稳后,负荷等值导纳模值只能在有限的范围内变化.研究了电压稳定问题的本质属性,认为电压稳定性应属于输出变量有界性问题.用戴维南等值定理分析了负荷稳定与电压稳定的关系.结果表明:负荷失稳的有界性决定了电力系统负荷稳定性不能等同于电压稳定性,负荷失稳不是电压失稳的充分条件;电力系统电压稳定性的本质属性决定了电压稳定性不仅与负荷稳定有关,而且与系统各元件和控制装置对电压的支持力度有关.对典型测试系统的仿真,证实了研究结果的正确性. 相似文献
4.
电力系统电压稳定性及其研究现状(二) 总被引:4,自引:2,他引:4
在第一部分介绍电压稳定定义、分类及分析方法的基础上,针对负荷对电压稳定研究的重要作用,介绍了常用的静态和动态负荷模型,并分析了负荷特性对电压稳定的影响。给出了电力系统电压失稳的几种典型场景,如中长期电压失稳、电压崩溃、电压升高失稳等。可通过无功补偿、变压器分接头紧急控制、发电计划重新安排、切负荷等措施进行电压稳定控制。指出需进一步研究的问题:电压稳定机理;发电机对电压稳定的作用;考虑电能质量要求的电压稳定性;电压稳定与功角稳定的关系;电压稳定性的定量指标;考虑负荷的静态和动态模型;直流输电对电压稳定的影响。 相似文献
5.
6.
负荷特性对电力系统静态电压稳定性的影响及静态电压稳定性广义实用判据 总被引:30,自引:4,他引:26
推导出考虑负荷静态电压特性的静态电压稳定条件和广义实用判据,阐述了静态电压失稳与电压崩溃的联系及其区别;分析了负荷静态电压特性对电力系统静态电压稳定性的影响,并指出:系统在鼻形曲线上半支运行时的静态电压稳定性主要取决于网络的电压—功率传输特性,而系统在鼻形曲线下半支运行时的静态电压稳定性则主要取决于负荷的静态电压特性。 相似文献
7.
负荷特性对电力系统静态电压稳定性的影响及静态电压稳定性 … 总被引:12,自引:3,他引:9
推导出考虑负荷静态电压特性的静态电压稳定条件和广义实用判据,阐述了静态电压失稳与电压崩溃的联系及其区别;分析了负荷静态电压特性对电力系统静态电压稳定性的影响,并指出:系统在鼻形曲线上半支运行时的静态电压稳定性主要取决于网络的电压-功率传输特性,而系统在鼻形曲线下半支运行时的静态电压稳定性则主要取决于负荷的静态电压特性。 相似文献
8.
9.
浅析电力系统负荷对电压稳定性的影响 总被引:11,自引:1,他引:10
介绍了负荷的静态模型和动态模型及模型参数的测量方法.定性分析了静态负荷特性与动态负荷特性及负荷建模对电压稳定性的影响.指出在电力系统的电压稳定分析中,发展动态负荷模型是研究电压稳定问题的关键和难点之一. 相似文献
10.
《电网技术》2017,(6)
为研究电动汽车接入电网后充电的不确定性和负荷波动特性对电网电压失稳事故的影响,提出了一种综合考虑电动汽车充电特性和负荷波动极限的电网静态电压稳定性评估方案。首先建立了系统中的发电机节点、负荷节点、电动汽车接入节点的注入功率随机化模型,充分考虑电网各元件的随机波动性;基于连续潮流和概率潮流相结合方法搜索系统的电压失稳临界状态,对电网的边界运行状态进行统计分析。文中提出了系统静态电压稳定性的评估指标体系,以确定电压稳定的薄弱区域。该薄弱区域在系统电压失稳状态下通常最先发生电压越限,可作为电网重要监控对象,以便及时采取切负荷措施,避免全网大停电的发生。IEEE 30节点算例分析结果验证了该方案的准确性和有效性。 相似文献
11.
12.
电力系统电压稳定机理及其应用探究 总被引:1,自引:0,他引:1
在总结国内外较有代表性的几种电压稳定性定义后,对短期电压失稳和长期电压失稳的机理进行分析,探讨了电压稳定性的主要分析方法,总结各种电压稳定性指标的特点,提出了下一步深入研究的方向.针对特大型城市电网的电压稳定性及其控制策略进行了初步探讨. 相似文献
13.
北京电网夏季电压稳定分析 总被引:2,自引:1,他引:2
北京电网是典型的受电大系统,电压稳定性就是负荷的稳定性。特别是夏季大负荷方式下,主网部分设备负载率高,存在某些异常运行方式.随着用电负荷的逐年增长,电压稳定性问题日趋严重,提出了基于电压稳定多项指标的分档加权预想事故筛选算法,借助于BPA潮流分析程序,计算了北京电网度夏正常运行方式和预想事故下的有功裕度指标、无功裕度指标和灵敏度指标,并排序比较指出北京电网夏季的薄弱节点薄弱区域和预想事故下系统电压稳定的削弱程度,为制定防止电压崩溃的预案提供了量化依据。 相似文献
14.
15.
Kumosa L. Armentrout D. Benedikt B. Kumosa M. 《Dielectrics and Electrical Insulation, IEEE Transactions on》2005,12(5):1043-1059
The applicability of using flat composite plates and hollow core composite cylinders for moisture absorption testing of unidirectional glass/polymer composites used in high voltage composite (non-ceramic) insulators was examined. Two main issues were addressed in this work. First, the effect of specimen geometry (cylinders vs. plates) on moisture absorption by the composites was investigated both numerically and experimentally. Both classical Fickian and non-Fickian diffusions were considered. Subsequently, hollow core cylinders made up of ECR (low seed)-glass fibers and epoxy resin were tested for their high voltage properties under controlled moisture diffusion conditions. The specimens were exposed to warm, moist air and their high voltage properties were ascertained using a modified version of the ANSI test (standard C29.11 Section 7.4.2) for water diffusion electrical testing. It was found that the behavior of the hollow core cylinder and flat plate composite specimens subjected to moisture compared reasonably well experimentally and very well numerically. From the high voltage tests, a direct correlation was found between the amount of moisture that had been absorbed by the specimens and the amount of leakage current that was detected. It was shown that using the thin walled composite cylinders leakage currents could be predicted based on the amount of absorbed moisture in the insulator composites. The predictions can be made based on relatively short term moisture data even if the diffusion process in the composites is anomalous in nature with long times required for full saturation. After additional verifications, considering other composite systems, the hollow core cylinder testing under controlled moisture and high voltage conditions could become a screening test for selecting suitable glass/polymer composites for insulator applications. 相似文献
16.
17.
有载调压变压器对系统中长期电压稳定性影响的仿真研究 总被引:2,自引:0,他引:2
应用电力系统中长期动态仿真软件Eurostag仿真研究有载调压变压器在系统不同的负荷特性下对中长期电压稳定性的影响。仿真分析表明, 有载调压变压器表现出“正调压效应”还是“负调压效应”主要取决于系统低压侧的负荷特性, 当系统重负荷且电压已经接近极限时, 对电压灵敏度高的负荷特性, 典型的是恒阻抗负荷, 有载调压变压器容易表现出“负调压效应”, 对系统电压稳定很不利; 受有载调压变压器调压影响不大的负荷特性, 典型的是恒功率负荷, 有载调压变压器对系统中长期电压稳定相当有利, 表现出很好的“正调压效应”。系统中有动态负荷时, 有载调压变压器容易表现出“负调压效应”, 但表现的程度受有载调压变压器的调压档距和容量的影响, 并且表现的方式也和静态负荷特性有所不同。 相似文献
18.
提出一种适用于地区电网静态电压稳定分析计算的改进奇异值分解法.该方法在形成雅可比矩阵时,考虑了ZM综合负荷模型的稳态特性对电压稳定的影响,通过对扩展雅可比矩阵进行奇异值分析,得到弱稳定节点和静稳裕度.通过算例仿真验证了该方法的有效性和合理性,算例结果表明考虑动态设备的稳态特性后的分析结果更能反映电网的真实状态,从而有利于电压稳定控制决策. 相似文献
19.
20.