首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 420 毫秒
1.
This paper presents a statistical model for estimating probability, which states that a quality of radon measurements using the electret ion chamber system RM-1 will be accurate. The quality of the electret measurement was modelled as a ratio between the reference radon concentration and values measured under real conditions with varied levels of indoor radon concentration and microclimate indoor conditions. It was stated that the accuracy tolerance of measured values is 20 % of the given reference value. To estimate the uncertainty of the statistical model, the exact confidence limits for the estimated probabilities are computed. The statistical model was confirmed by an independent set of measurements. Moreover, the effect of absolute humidity on the quality estimation of electret detectors are also statistically analysed and discussed. The results of the statistical model confirm that the electret system is robust and suitable for estimation of radon concentration.  相似文献   

2.
The authors present the results of a year-long survey of the indoor radon concentration levels in the FYR of Macedonia. A total number of 437 dwellings in eight statistical regions were subject to radon concentration measurements by using CR-39 track detectors. The annual mean indoor radon concentration in each measuring site was estimated from the four individual measurements with 3 months duration. The measuring period was from December 2008 to December 2009. The distribution of the results was nearly log-normal. The arithmetic and geometric mean values of the annual mean value of radon concentration were estimated to be 105 ± 84 and 84*/1.9 Bq m(-3), respectively. The annual effective dose due to indoor exposure to radon in the dwellings was estimated to be 2.1*/1.9 mSv y(-1).  相似文献   

3.
对开环式测量氡析出率方法进行了验证,测得的介质表面氡析出率与参考值符合得较好。通过理论分析得到了集氡罩内的氡浓度趋于恒定值的时间表达式;提出了采用底面积较大的集氡罩,并加一调节阀来调低泵的流量的方法来提高集氡罩内的氡浓度,减小RAD7测量时的统计涨落。  相似文献   

4.
The purpose of this study was to measure radon concentration in public primary schools located in priority investigation areas, with the aim of decreasing occupants' exposure to radon in public buildings where concentrations exceed the Canadian Federal guidelines (i.e. 200 Bq m(-3)). In addition, the association between radon levels, substratum geological characteristics and schools' structural characteristics were investigated. The results showed that radon concentrations measured in the 65 investigated schools are generally below the Federal guideline levels. Eleven schools (17 %) had at least one measurement above the Federal guideline, while one had a level above 600 Bq m(-3). On average, targeted schools' occupants are exposed to radon concentrations of 56 Bq m(-3). Although statistical analysis, which was limited by the sample size, did not show any link between aggregated radon measurements and geochemical or radiological signatures of investigated sites, the geological evidence that led to the choice of the studied regions remains relevant.  相似文献   

5.
High indoor radon concentration means an increased risk of developing lung cancer. When high radon levels are present in a dwelling, the major source is normally the soil. Therefore, it is useful to know the radon concentration field in the soil underneath a building. A steady-state two-dimensional radon transport model has been used to calculate the effect of a reference building on the soil radon concentration, and the influence of soil parameters on radon entry through a single crack in the basement. Both advective and diffusive flows are considered. Away from the building, the well-known undisturbed soil radon concentration profile has been obtained, while under the house the radon level is increased. A variability analysis around the reference site has shown that the most relevant soil parameters on the radon flux at the top of the crack are, in this case, effective diffusion coefficient, soil gas-permeability and deep soil radon concentration.  相似文献   

6.
A linear regression model has been developed for the prediction of indoor (222)Rn in Danish houses. The model provides proxy radon concentrations for about 21,000 houses in a Danish case-control study on the possible association between residential radon and childhood cancer (primarily leukaemia). The model was calibrated against radon measurements in 3116 houses. An independent dataset with 788 house measurements was used for model performance assessment. The model includes nine explanatory variables, of which the most important ones are house type and geology. All explanatory variables are available from central databases. The model was fitted to log-transformed radon concentrations and it has an R(2) of 40%. The uncertainty associated with individual predictions of (untransformed) radon concentrations is about a factor of 2.0 (one standard deviation). The comparison with the independent test data shows that the model makes sound predictions and that errors of radon predictions are only weakly correlated with the estimates themselves (R(2) = 10%).  相似文献   

7.
Indoor air samples taken in buildings throughout the provinces of Cáceres and Badajoz in the Autonomous Community of Extremadura, Spain, were analysed for airborne radon concentrations using charcoal canisters. Measurements were made during the years 1998-2000. The geometrical mean indoor concentration was 90 Bq m(-3). An estimated annual effective dose of 1.6 mSv y(-1) was calculated for residents, assuming an equilibrium factor of 0.4 and an occupancy factor of 0.8. The relative importance of the principal variables that condition radon concentrations inside buildings was also delimited experimentally. These were: soil type, construction materials used, the height of the room above ground level, and the degree of ventilation. The temporal evolution of the radon concentration was analysed, as this aspect could be particularly important in a Continental-Mediterranean climate such as that of the two provinces of the study.  相似文献   

8.
Granite aggregates are known to be the radon source in concrete. Recently, metakaolin has been introduced as a partial substitution of Portland cement to produce high strength concrete. It can effectively reduce the porosity of both the matrix and the aggregate/paste transition zone, which suggests its ability to retard radon emission from concrete aggregates. In the present work, radon exhalation rates from concrete cubes substituted with metakaolin were measured using charcoal canisters and gamma spectroscopy, and were considerably lower than those from normal concrete, by about 30%. The indoor radon concentration reduction is estimated as approximately 9 Bq m(-3) calculated using a room model, causing a 30% reduction in the indoor radon concentration and the corresponding radon dose. Therefore, metakaolin is a simple material to reduce the indoor radon concentration and the radon dose.  相似文献   

9.
Soil gas radon measurements are carried out in a pilot study in three municipalities in Upper Austria. The selected municipalities are characterised by a high radon potential. Sixty measuring sites--well distributed over the region and over the different geological areas--were selected. Additionally, the permeability of the soil was determined where the soil gas samples were taken and at various sites where soil samples were analysed by gamma spectrometry. Long-term soil-gas radon concentration measurements are carried out at several sites to study the long-term behaviour of radon activity concentration in soil, the influence of meteorological parameters and seasonal variations. The final goal of the project is to correlate the collected data with geological data and indoor radon concentration. First results of this ongoing study are presented and discussed.  相似文献   

10.
In this paper the focus is on Arnea Chalkidikis, an area in Greece with granitic geological background and indications of possible elevated radon concentration indoors. Data are reported of indoor radon measurements with etched track detectors and those are used for dosimetric estimations. Moreover, data are reported on soil gas and soil radon concentrations in Arnea, as well as radon and uranium concentrations in water samples. From the measured radon concentrations in water samples the contribution to the overall dose has been calculated. For a period of 1 month, indoor radon and progeny activity has also been monitored in the dwelling that has the maximum indoor radon concentration in Greece. This dwelling is in Arnea and the dose delivered to the inhabitants has been calculated. The mean annual effective dose due to indoor radon was 4.5 mSv and about 11% of this was due to the use of water. Mean soil gas concentration and soil radon concentration were (90 +/- 30) kBq m(-3) (p<0.05) and (30 +/- 5) kBq m(-3) (p<0.05) respectively. Mean uranium concentration of the water samples was (98 +/- 13) mBq l(-1) (p<0.05).  相似文献   

11.
R. Rabi  L. Oufni 《Mapan》2018,33(2):123-130
The aim of this work is to studying indoor radon distribution using the Finite Volume Method (FVM). This paper focuses on effects of exhalation from different sources (wall, floor and ceiling) and the ventilation profile on distribution the concentrations of radon indoor. The rate of radon exhalation and ventilation were measured and are used as input in FVM simulation. It has been found that the radon concentration is distributed in non homogeneous way in the room. The radon concentration is much larger near floor, and decreases in the middle of the room. The experimental validation was performed by measuring radon concentration at different locations in room using active and passive techniques. We notice that the results of simulation and experimental are in agreement. The annual effective dose of radon in the model room has been also investigated.  相似文献   

12.
标准氡室在氡浓度量值溯源和传递中起着重要作用。为了保证测氡仪量值统一、准确可靠,建立了测氡仪检定装置。针对在建立标准过程中出现的流气式氡源泄漏、氡室实验累积氡浓度值与理论值不一致和液体镭源结晶等问题,重点研究多重密封、改造洗气管路、优化洗气模式及多重过滤等技术方法,并建立氡室累积氡浓度经验曲线和质量管理措施等。按照新建立的实验方法和实验流程,氡室实验调节氡浓度和理论累积氡浓度相对偏差在±3.8%以内,液体镭源长期稳定性在0.7%以内,符合氡室建标的计量性能要求。  相似文献   

13.
Indoor radon concentrations are subject to diurnal and seasonal variations. In order to obtain an unbiased estimate of the annual mean radon concentration, measurements made over periods less than 12 months have to be adjusted accordingly. In this paper, hourly radon measurements from one uninhabited rural house in Telecí in the Czech Republic have been analysed. The data were collected over a period of 1 y. The behaviour of the radon concentration with time and its relationship with the outdoor temperature, wind speed and atmospheric pressure have been studied. Different estimates of the annual mean radon concentration based on short-term continuous measurements have been assessed.  相似文献   

14.
In this study, we report on the indoor radon concentration levels in a number of locations scattered in the Hebron province, Palestine. The measurements were performed during the winter season of the year 1999/2000 using the CR-39 detectors. The radon concentration levels were found to vary from 23 to 580 Bq m(-3). The arithmetic average of the obtained radon concentration levels was found to be 91 Bq m(-3). It was found that most of the radon concentration levels in houses and school rooms are below the low reference levels limits. Most of the high-radon concentration levels were found in unpainted storage rooms.  相似文献   

15.
The results of measurement of atmospheric radon concentration in Beijing, China, are reported. Continuous observation was performed hourly throughout 2003 to provide data on annual average radon concentration as well as the variation of radon concentration. An arithmetic annual mean value of 14.1 +/- 5.5 Bq m(-3) was obtained. The value was slightly higher than the world average and the national average. For the monthly average radon concentration, the maximum was 18.5 +/- 5.0 Bq m(-3) in November, while the minimum was 9.9 +/- 4.1 Bq m(-3) in May. Diurnal variation was also observed, and the average daily pattern of radon concentration consisted of a minimum in the late afternoon and a maximum in the early hours of the morning.  相似文献   

16.
Extensive radon surveys have been carried out in many countries only in dwellings, whereas surveys in workplaces are rather sparse and generally restricted to specific workplaces/activities, e.g. schools, spas and caves. Moreover, radon-prone areas are generally defined on the basis of radon surveys in dwellings, while radon regulations use this concept to introduce specific requirements in workplaces in such areas. This approach does not take into account that work activities and workplace characteristics can significantly affect radon concentration. Therefore, an extensive survey on radon in different workplaces have been carried out in a large region of Italy (Tuscany), in order to evaluate radon distribution in workplaces over the whole territory and to identify activities and workplace characteristics affecting radon concentration. The results of this extensive survey are compared with the results of the survey carried out in dwellings in the same period. The workplaces monitored were randomly selected among the main work activities in the region, including both public and industrial buildings. The survey monitored over 3500 rooms in more than 1200 buildings for two consecutive periods of ~6 months. Radon concentration was measured by means of passive nuclear track detectors.  相似文献   

17.
Indoor radon concentration measurement in the dwellings of Al-Jauf region of Saudi Arabia was carried out using passive radon dosemeters. The objective of this radon survey was to obtain representative indoor radon data of Al-Jauf region. The study is a continuation of radon survey in main cities of Saudi Arabia which constitutes a baseline for Saudi Arabia in the Radon World Atlas. A total of 318 passive radon dosemeters were distributed randomly in the region and placed for a period of 1 y starting from April 2004 to April 2005. The results of indoor radon concentration measurement in 136 dwellings distributed in Al-Jauf region are presented. The remaining dosemeters were lost in the dwellings or mishandled. The results showed that the average, minimum, maximum radon concentrations and standard deviation were 35, 7, 168 and 30 Bq m(-3), respectively. Geometric mean and geometric standard deviation of the radon distribution were found to be 28 and 1.83, respectively.  相似文献   

18.
A radon test facility for small animals was developed in order to increase the statistical validity of differences of the biological response in various radon environments. This paper illustrates the performances of that facility, the first large-scale facility of its kind in Japan. The facility has a capability to conduct approximately 150 mouse-scale tests at the same time. The apparatus for exposing small animals to radon has six animal chamber groups with five independent cages each. Different radon concentrations in each animal chamber group are available. Because the first target of this study is to examine the in vivo behaviour of radon and its effects, the major functions to control radon and to eliminate thoron were examined experimentally. Additionally, radon progeny concentrations and their particle size distributions in the cages were also examined experimentally to be considered in future projects.  相似文献   

19.
The lung dose derived from radon is not attributed to the radon gas itself, but instead to its short-lived progeny. However, in many epidemiological studies as well as in case control studies of the radon risk, the excess number of cancers are related to the radon gas exposure, and not to the radon progeny exposure. A justification for such an approach has resorted to the assumption that there is self-compensation between the radiation doses from the unattached and attached fractions. In the present study, we used the Jacobi model to calculate the radon progeny concentrations in a room by varying the attachment rate and then calculated the resulting lung dose. It was found that self-compensation was not fully realised, and the effective dose can vary by a factor up to approximately 2 for the same radon gas concentration. In conclusion, the radon gas concentration alone does not provide adequate information on the effective dose.  相似文献   

20.
Radon measurements were carried out in Kozlu, Karadon and Uzülmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) in the study area. The radon concentration measurements were performed on a total of 42 points in those three mines. The annual exposure, the annual effective dose and lifetime fatality risk, which are the important parameters for the health of workers, were estimated based on chronic occupational exposure to the radon gas, which is calculated using UNCEAR-2000 and ICRP-65 models. The radon concentrations at several coal production faces are higher than the action level of 1000 Bq m(-3). It is suggested that the ventilation rates should be rearranged to reduce the radon concentration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号