R22 制冷剂替换在即,R32 制冷剂是一种潜在的且经济的替代制冷剂.本文通过分析R32制冷剂的物理性质和理论热工循环参数,并采用空调用涡旋式压缩机进行试验测试,同时与 R410A 制冷剂进行试验对比.试验结果表明,R32 制冷剂替代当前的 R22 制冷剂作为空调制冷剂应用,对于空调用涡旋式压缩机来说,其整体表现与 R410A 制冷剂相类似.但为了取得更好的性能和可靠性,压缩机应针对 R32 制冷剂在空调工况应用时压力高、排气温度高的特点进行设计改进.  相似文献   

2.
R32制冷剂     
周子成 《制冷》2014,(2):37-44
自从1997年京都会议以后, R22和R410a都被认为是需要淘汰的制冷剂,世界各国都在寻找合适的替代制冷剂,并作为重要的任务。 R32被认为是一种有潜力的替代R22与R410a在空调器中使用的制冷剂。本文综述R32替代的可行性和它与R410a的性能比较。  相似文献   

3.
本文介绍了我国家用空调器行业HCFCs制冷剂淘汰计划并说明研究R32作为R410A替代制冷剂的必性。比较了R32和R410A制冷剂的特性及替代可行性。以KFR-25GW/Bp变频空调器为对象,实机测试R32和R410A在相同空调系统中的空调器性能。以便给国内家用空调器行业选择使用R32制冷剂提供有益的参考。  相似文献   

4.
R134a与R410A在空调工况下的性能比较   总被引:1,自引:0,他引:1  
陈武  周兴禧  唐良猷 《制冷技术》2002,(4):15-16,20
传统制冷剂R22的替代已是大势所趋.本文着重对R22的替代制冷剂R134a与R410A的传热、阻力压降特性进行实验比较研究,认为R410A在传热、阻力压降特性方面比R134a优良,作为R22的替代制冷剂,R410A应比R134a更有竞争力.  相似文献   

5.
从理论上对R32,R410A和R22的性质进行对比,认为R32是一种可能的R22和R410A的替代品,对其进行相关试验验证,并给出R32在实际应用中的相关安全措施。  相似文献   

6.
在家用/商用空调中用R32替代R22的探索   总被引:9,自引:3,他引:6  
在R22的替代工作进入实质性阶段,但国内外成熟替代品又尚不明朗之际,本文在分析国内外R22替代物的现状、存在的问题以及国际上对环保工质要求的新趋向的前提下,探索提出在家用/商用空凋中使用R32替代R22的设想,并从其热物理性质、环保特性、安全性、热工性能、市场可获得性等几个方面,与现有的R22替代物R410A,R290和R1234yf等进行比较,认为R32是一种兼顾减排、安全、节能和市场诸方面要求的、很有前景的R22替代制冷剂。  相似文献   

7.
低温室效应HCFCs替代物性能分析   总被引:7,自引:2,他引:5  
在阐述目前国内外HCFCs替代形势的基础上,对热泵空调及冷冻冷藏系统典型HCFCs制冷剂R22和其传统替代制冷剂(R410A,R407C,R404A,R507A),以及低温室效应R22替代物(R161,R290,RTJU4,R32,R717及R1234yf)的热力性能、循环性能及其可燃特性进行对比与分析.结果表明,R161,R290,RTJU4,R717,R32不仅具有零ODP较低GWP值的优势,其热力学及传热学特性也优于传统的HCFCs替代物,其中部分工质在一定的应用条件下具有较好的循环性能.R32,R1234yf和RTJU4的可燃性较小;RTJU4在系统循环性能上具有较明显的优势;R717具有较好热力学、传热学和循环特性,经进一步的系统和部件改进也具有较强的替代潜力.  相似文献   

8.
本文介绍了低GWP环保替代制冷剂R454B和R452B与现有行业内常用的R410A制冷剂的特性参数对比,并基于同一套压缩机测试系统,对比这两种制冷剂的制冷量和性能等参数测量结果的变化趋势。结果显示直接使用R454B制冷剂替换R410A将会平均降低约5.6%的制冷量,R452B平均降低约3%的制冷量。但在较低蒸发温度和较高冷凝温度的工况区域R454B/R452B制冷剂能够带来更高的能效优势,因此,依照实际应用差异能够为日后推动环保制冷剂直接替换和新系统的使用提供理论依据。  相似文献   

9.
制冷剂R32特性及其用于空气源热泵热水器的理论循环分析   总被引:1,自引:0,他引:1  
介绍R32,R22和R407C以及R410A四种制冷剂的流动特性和热力学特性,并对采用这4种制冷剂的空气源热泵热水器进行理论循环分析。从计算结果可以看出,与采用其他3种制冷剂的系统对比,采用R32制冷剂的系统具有较低的压缩比,较高的理论COP以及容积制热量;在当前阶段,R32是用于空气源热泵热水器的一种较好的制冷剂。  相似文献   

10.
为从能量"质"的方面揭示R32替代R22的合理性,分别对使用R22和R32作制冷剂的制冷系统,在ARI 520标准的空调工况下进行分析,首先对整个循环系统进行分析,得到系统的效率和冷量,然后分析制冷循环各环节损失的原因,给出各环节的效率、损失和损失系数的计算表达式,并进行计算和比较。分析表明,R32的制冷系统更有利于能量的充分利用,而且主要是压缩环节损失明显减少,说明R32替代R22的可行性。  相似文献   

11.
目前家用空调器R22的替代制冷剂,主要是R407C和R410A。由于这些制冷剂的专利权都在国外,且价格高昂,为此,国内浙江化工研究院开发出一种可替代R410A,且部分性能优于R410A的新型环保制冷剂。受该单位委托,笔者所在公司对该制冷剂进行了实机测试分析。  相似文献   

12.
在已建立的数学模型的基础上,对板式蒸发器换热能力进行了数值模拟.针对应用较广的R134a和R410A制冷剂来比较和分析板式蒸发器在小的温差下的换热性能.在三种不同的计算工况下简要分析了各种热力参数的变化对蒸发器整体换热性能的影响.不同的制冷剂,其换热系数和压降差别较大,相同工况下采用R410A替代R22,板式蒸发器的换热性能可提高8.5%~10.0%,且压降可大幅降低.  相似文献   

13.
Compressor-destruction accidents during the pump-down operation of air conditioners were experimentally investigated. Assuming air penetration into refrigerant tubes, the gaseous mixture of the air, refrigerant, and lubricating oil for a compressor was compressed by the compressor with different refrigerant concentrations, and the diesel combustion of the mixture was examined. The compressor was simulated by a small-scale engine. R1234yf, R32, R410A, R134a, R22, and R125 were tested as refrigerants. The mixture burned via adiabatic compression when the refrigerant concentration was low, which means that accidents during the pump-down were caused by the diesel combustion of the mixture. The refrigerant burned and caused intense pressure increase. The mixture without the oil did not burn under any refrigerant concentration, which suggests that oil is necessary for the combustion. These phenomena were observed in the results for R1234yf, R32, R410A, R134a, and R22. Thus, combustion was observed under certain conditions even for refrigerants categorized as non-flammable.  相似文献   

14.
对R22、R407c、R134a三种制冷剂的基本物性及热力性能进行了分析比较,并在风冷螺杆热泵机组基础上进行了替换试验研究。结果表明:R407c为最佳替换R22的制冷剂;R134a替换后能效比较高,但制冷(热)量衰减过多,同时R134a的运行压力过低不太适合热泵工况。  相似文献   

15.
R32由于具有ODP为零、GWP值小于R410A等优越的环境性能,逐渐被认识到可以用于替代R410A。这里对R410A和R32的循环性能、润滑油的选用、可燃性、充注量、换热器性能等相关问题进行了综述。大量研究表明,与R410A系统相比,R32系统的压缩机耗功略高,制冷量较高,同时排气温度也高出很多,具有极大的替代R410A的潜力。然而,相关研究也指出要使其能够在大范围推广使用,除了要有效解决排气温度过高的问题之外,还需要解决其微可燃性在设计应用中所受到的限制。通过解读国内外法规政策发现,国内外对R32的充注量限制有放宽的趋势,这对R32在常规空调热泵系统中替代R410A和R22的研究工作将是一个巨大的推动。  相似文献   

16.
采用分布参数法对波纹型通道板式蒸发器建立数学模型,并进行了数值模拟.通过计算板内局部蒸发传热系数和压降可以简化板式蒸发器内复杂三维网状流动的传热特性.针对应用较广的R134a和R410A制冷剂来比较和分析板式蒸发器在小的温差下的传热性能.在3种不同的计算工况下简要分析了各种热力参数的变化对蒸发器整体传热性能的影响.不同的制冷剂,其传热系数和压降差别较大,相同工况下采用R410A替代R22,板式蒸发器的传热性能可提高8.5%~10.0%,且压降可大幅降低.  相似文献   

17.
In the present paper, the refrigerant mixture R32/R290 (68%/32% by weight) is investigated as the drop-in replacement for R410A in household air conditioners. The GWP of it is only 22% of that of R410A. Theoretical and experimental investigations are conducted on the performance of the air conditioners working with both R32/R290 and R410A. Experimental results show that the refrigerant charge amount of R32/R290 is reduced by 30.0%–35.0%; the cooling and heating capacities are increased by 14.0%–23.7%. For further reducing charge amount and flammability, the micro-channel heat exchanger (condenser) is employed to replace the finned tube one. Compared with the R32/R290 system using finned tube heat exchanger, the R32/R290 charge amount and the power consumption are reduced by 34.1% and 0.4%, respectively; the cooling capacity and the COP are increased by 6.4% and 6.8%, respectively.  相似文献   