首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 781 毫秒
1.
This study investigates the correlation between the thermal cycles experienced by Alloy 690 weldments fabricated using gas tungsten arc welding (GTAW) and laser beam welding (LBW) processes, and their corresponding corrosion resistance properties. The corrosion resistance of the weldments is evaluated using a U-bend stress corrosion test in which the specimens are immersed in a boiling, acid solution for 240 h. The experimental results reveal that the LBW inputs significantly less heat to the weldment than the GTAW, and therefore yields a far faster cooling rate. Moreover, the corrosion tests show that in the GTAW specimen, intergranular corrosion (IGC) occurs in both the fusion zone (FZ) and the heat affected zone (HAZ). By contrast, the LBW specimen shows no obvious signs of IGC.  相似文献   

2.
This study investigates the effects of welding method, peak temperature, and cooling rate on the susceptibility to intergranular corrosion of alloy 690 weldments. The experimental results reveal that the laser beam welding process with cooling rate of around 212.6 °C/s can be produced with much less mass loss and a lower value of maximum reactivation current density/maximum anodic current density than with the gas tungsten arc welding process, where cooling rate is at around 17-20.6 °C/s. This is because the very rapid cooling rate during welding leads to an insufficient exposure time of around 2.1 s within the chromium (Cr)-carbide precipitation temperature range, suppressing Cr-carbide precipitation and Cr-depletion along grain boundaries in the weld decay region of the heat affected zone.  相似文献   

3.
The intergranular corrosion susceptibility in supermartensitic stainless steel (SMSS) weldments was investigated by the double loop – electrochemical potentiokinetic reactivation (DL-EPR) technique through the degree of sensitization (DOS). The results showed that the DOS decreased from the base metal (BM) to the weld metal (WM). The heat affected zone (HAZ) presented lower levels of DOS, despite of its complex precipitation mechanism along the HAZ length. Chromium carbide precipitate redissolution is likely to occur due to the attained temperature at certain regions of the HAZ during the electron beam welding (EBW). Scanning electron microscopy (SEM) images showed preferential oxidation sites in the BM microstructure.  相似文献   

4.
AISI type 316 austenitic stainless steel in sensitized condition was subjected to ASTM A262 practice A test (electrolytic etching in 10% ammonium persulphate at 1 A/cm2) for various durations from 10 s to 90 s. The different degrees of intergranular corrosion attack produced on these tested specimens were evaluated by laser scattering technique using a 1 mW He-Ne laser. The scattering intensity pattern of the laser beam incident on the specimen was acquired using a CCD camera and transferred to a computer for further analysis. The specular intensity of the scattering pattern and its full width at half maximum (FWHM) was calculated. The results indicated that the specular intensity decreased and the FWHM increased as the degree of IGC attack increased. A good correlation was found between the extent of IGC with the laser scattering parameters.  相似文献   

5.
The change in the mechanism of stress corrosion cracking with test temperature for Type 304, 310 and 316 austenitic stainless steels was investigated in boiling saturated magnesium chloride solutions using a constant load method. Three parameters (time to failure; tf, steady-state elongation rate; lss and transition time at which a linear increase in elongation starts to deviate; tss) obtained from the corrosion elongation curve showed clearly three regions; stress-dominated, stress corrosion cracking-dominated and corrosion-dominated regions. In the stress corrosion cracking-dominated region the fracture mode of type 304 and 316 steels was transgranular at higher temperatures of 416 and 428 K, respectively, but was intergranular at a lower temperature of 408 K. Type 310 steel showed no intergranular fracture but only transgranular fracture. The relationship between log lss and log tf for three steels became good straight lines irrespective of applied stress. The slope depended upon fracture mode; −2 for transgranular mode and −1 for intergranular mode. On the basis of the results obtained, it was estimated that intergranular cracking was resulted from hydrogen embrittlement due to strain-induced formation of martensite along the grain boundaries, while transgranular cracking took place by propagating cracks nucleated at slip steps by dissolution.  相似文献   

6.
The spreading of intergranular corrosion was investigated using micrometer scale simulations and experimental verifications on sensitized stainless steel [UNS S30400]. The degree of sensitization, presence of a pit, and applied potential all affected spreading. The inputs used in the simulation were obtained from Fe-XCr(X = 10, 12, 14, 16 wt.%)-Mo-Ni alloys representing various grain boundary Cr depletion levels. Corroding grain boundaries and pits triggered corrosion of nearby sensitized boundaries due to Ohmic potential drop. Large connected clusters of corroding grain boundaries formed at high fractions of Cr-depleted grain boundaries. The metallurgical, electrochemical and geometric conditions for this behavior could be forecasted.  相似文献   

7.
Electrochemical potentiokinetic reactivation technique (EPR) was employed to assess degree of sensitization in 316L stainless steel diffusion bonded joint (DBJ). The result showed the degree of sensitization of DBJ was much smaller than that of base material (BM). No chromium carbides precipitated at grain boundaries in DBJ after 100 h treatment at 650 °C, while chromium carbides could be seen clearly in the BM after 8 h treatment, indicating that DBJ has better intergranular corrosion resistance than BM. Diffusion bonding technique will not increase intergranular corrosion susceptibility of 316L DBJ. Reactivation potential has the biggest effect on sensitization.  相似文献   

8.
J. Flis 《Corrosion Science》2008,50(6):1726-1733
Anodic behaviour of decarburised iron and of quenched Fe-C materials with up to 0.875 wt% C was examined in 8.5 M NaOH at 100 °C to explain the role of carbon in caustic stress corrosion cracking (SCC) of plain steels. Removal of carbon from Armco iron strongly reduced its intergranular SCC. Slip steps on grains did not initiate cracks. It has been shown that carbon at low contents deteriorates the passivation of iron, whereas at high contents it promotes the formation of magnetite. High resistance to SCC of high carbon steels can be explained by an intense formation of magnetite on these steels.  相似文献   

9.
The degree of sensitization (DOS) in resistance spot welding (RSW) joints is considered as the combined effect of intergranular corrosion (IGC) and transgranular corrosion (TGC) in the heat affected zone (HAZ) and of interdendritic corrosion (IDC) in the weld nugget (WN). The DOS is evaluated from electrochemical potentiokinetic reactivation (EPR) tests. The application of EPR test to RSW joints is optimized and an electrochemical minicell is used to study the effect of heat input on IDC in the WN.  相似文献   

10.
A photon rupture method, film removal by a focused pulse of pulsed Nd-YAG laser beam irradiation, has been developed to enable oxide film stripping at extremely high rates without contamination from the film removal tools. In the present study, Zn-55mass%Al alloy and Al-9mass%Si alloy-coated steel specimens covered with protective nitrocellulose film were irradiated with a focused pulse of a pulsed Nd-YAG laser beam at a constant potential in 0.5 kmol m−3 H3BO3-0.05 kmol m−3 Na2B4O7 (pH = 7.4) with 0.01 kmol m−3 of chloride ions to investigate the initial stage of localized corrosion. At low potentials, oxide films on both coated alloys were reformed after the nitrocellulose films were removed by this method. The oxide film formation kinetics follows an inverse logarithmic law, in agreement with Cabrera-Mott theory. However, at high potentials, localized corrosion producing corrosion products occurs at the area where nitrocellulose film was removed. Nevertheless, when the applied potential is less noble, the dissolution current of the Zn-55mass%Al-coated steel samples is higher than that of Al-9mass%Si-coated samples.  相似文献   

11.
The influence of ageing heat treatments (675 and 875 °C for 1.5 to 48 h) on the microstructure and intergranular corrosion resistance of sintered in nitrogen duplex stainless steels was investigated. The materials were obtained by sintering mixtures of austenitic AISI 316L and ferritic AISI 430L powders. Corrosion behaviour was evaluated by using electrochemical techniques. The beneficial effect of nitrogen on corrosion behaviour of solution annealed samples was established. During ageing, secondary phases were precipitated and the intergranular and transgranular corrosion resistance significantly decreased though repassivation was observed in specimens aged at 875 °C for times up to 8 h.  相似文献   

12.
Intergranular corrosion (IGC) of type 409L ferritic stainless steel (FSS) was investigated. A free-exposure corrosion and a double loop electrochemical potentiokinetic reactivation (DL-EPR) tests were conducted to examine IGC of the FSS. IGC occurred in the specimens aged at the temperature range of 400–600 °C that has the sensitization nose located around 600 °C. The critical Ir/Ia value was determined to be about 0.03 above which IGC occurred. Based on the analysis of the intergranular precipitates by an energy dispersive spectroscopy (EDS) and a transmission electron microscopy (TEM), IGC was induced by the Cr depletion zone formation due to Cr segregation around intergranular TiC.  相似文献   

13.
In the simulated heat affected zone of 2205 duplex stainless steels, effects of large welding heat inputs on the microstructure and corrosion behaviour were investigated. Reformed austenite content increased with the coarsening of grain boundary austenite (GBA) and the growth of intragranular austenite (IGA) and Widmanstatten austenite (WA), thus improving the low temperature toughness and affecting corrosion state. Reduction of chromium nitrides contributed to better resistance to pitting corrosion. Moreover, the pitting corrosion and intergranular corrosion were improved resulting from the formation of more GBA and WA. The specimen with a Δt8/5 of 100 s presents better comprehensive performance.  相似文献   

14.
Two types of coating-modified 3D C/SiC, coated with CVD SiC/SiC/SiC (type I) and CVD SiC/amorphous-BC/SiC (type II), are subjected to a 14 vol.% H2O/8 vol.% O2/78 vol.% Ar atmosphere at 700, 1000 and 1200 °C up to 100 h. Microstructure and corrosion behaviour are investigated using a variety of characterization techniques. The type II shows a better oxidation resistance than type I during annealing at relatively low temperatures. Nevertheless, residual strength of the type I annealed above 1000 °C is enhanced by healing of many micron-sized defects. Interfacial bond strength of the composites is reasonably improved after annealing.  相似文献   

15.
Abstract

The residual welding stresses in laser beam (LB) and tungsten inert gas (TIG) weldments of a titanium alloy in thin plate form were investigated experimentally in the present work. A hole drilling technique was used to measure the residual stresses in the weldments. The effects of the welding method and post-weld heat treatment (PWHT) on the residual stresses were analysed. The results show that (i) the residual stress distribution in the LB welded joints is similar to that obtained for traditional fusion welding processes, although the distribution zone is much narrower in LB welding, (ii) the residual stress in the heat affected zone for LB welding is about 100 MPa lower than that for TIG welding, and (iii) PWHT in vacuum greatly relieves the welding residual stress.  相似文献   

16.
Copper containing 6000-series aluminium alloys may become susceptible to intergranular corrosion (IGC) as a result of improper thermomechanical processing. Effect of cooling rate after solution heat treatment on the corrosion behaviour of a model AlMgSi(Cu) alloy of nominal composition (wt%) 0.6 Mg, 0.6 Si, 0.2 Fe, 0.2 Mn and 0.1 Cu was investigated. Slow cooling rates were simulated by isothermal treatment for predetermined times in lower temperature baths immediately after solution heat treatment. Treatment for 10-100 s at temperatures below 400 °C introduced susceptibility to IGC. Longer heat treatment at the same temperatures introduced susceptibility to pitting. A corrosion resistant time zone was found between the zones of IGC and pitting at temperatures lower than 350 °C. Quenching in water after solution heat treatment prevented IGC. IGC was related to microgalvanic coupling between the noble Q-phase (Al4Mg8Si7Cu2) grain boundary precipitates and the adjacent depleted zone. Pitting was attributed to coarse particles in the matrix. Possible mechanisms causing the corrosion resistant intermediate zone are discussed. The results indicate possible methods for obtaining increased corrosion resistance of similar alloys by proper thermal processing.  相似文献   

17.
The corrosion behaviour of several metals and metal alloys (copper, nickel, AISI 1018 steel, brass, Inconel 600) exposed to a typical ionic liquid, the 1-butyl-3-methyl-imidazolium bis-(trifluoromethanesulfonyl) imide, ([C4mim][Tf2N]), has been investigated by electrochemical and weight-loss methods. Corrosion current densities have been determined by extrapolation from Tafel plots and by polarization resistance measurements and 48 h immersion tests were performed at 150, 250, 275 and 325 °C. Room temperature results show low corrosion current densities (0.1-1.2 μA/cm2) for all the metals and alloys investigated. At 70 °C, the corrosion current for copper dramatically increases showing a strongly dependence on temperature. At 150 °C copper shows significant weight-loss while nickel, AISI 1018, brass and Inconel do not. At higher temperatures (?275 °C), the copper sample crumbles and localized corrosion occurs for the other metals and alloys.  相似文献   

18.
UNS S17400 or 17-4PH is a precipitation hardening martensitic stainless steel with many industrial applications. Quite different mechanical properties can be produced in this material by varying the aging temperature. In this work, the influence of aging temperature on the intergranular corrosion susceptibility was evaluated by electrochemical and metallographic tests. The microstructural features were investigated by X-ray diffraction, optical and scanning electron microscopy. Intergranular chromium carbide precipitation occurs in specimens aged at high temperatures, although NbC carbides were also observed. The results obtained by double loop electrochemical potentiodynamic reactivation tests (DL-EPR) show that the susceptibility to intergranular corrosion resistance increases with the increase of aging temperature. Healing due to Cr diffusion in the 600-650 °C range was not observed by DL-EPR tests.  相似文献   

19.
This paper identified the effects of Ti and Nb on pitting and intergranular corrosion resistance in a ferritic stainless steel weld metal of the automobile exhaust system. We fabricated 4 flux cored wires designed with 0–0.2 wt% Ti and 0–1.0 wt% Nb and performed Flux Cored Arc Welding. Through the potentiodynamic polarization test in 0.5M NaCl, we evaluated pitting resistance. And in order to evaluate the intergranular corrosion resistance, we observed microstructure after we performed DL-EPR test in 0.5M H2SO4+0.01M KSCN. As a result of the test, the specimen added with 0.2%Ti+1.0%Nb showed the highest pitting resistance. From observing the degree of sensitization and microstructure, the intergranular corrosion resistance was higher as the contents of Ti and Nb increased. And through EBSD we observed Cr carbide which affects the corrosion resistance.  相似文献   

20.
Y. Sun 《Corrosion Science》2010,52(8):2661-4290
The electrochemical corrosion behaviour of the carburised (expanded austenite) layer on 316L austenitic stainless steel produced by low temperature plasma carburising has been studied in 0.5 M NaCl and 0.5 M HCl + 0.5 M NaCl solutions. The present work focuses on the variation of the corrosion behaviour of the carburised layer with depth from the surface and the effect of carbon concentration on electrochemical behaviour. The results show that the carburised layer has excellent resistance to localised corrosion. There exists a critical carbon concentration, above which the expanded austenite possesses excellent resistance to both metastable pit formation and pit growth.  相似文献   