共查询到20条相似文献,搜索用时 125 毫秒
1.
针对交直流系统中影响暂态稳定电磁转矩和机械转矩平衡控制问题变参数特性,结合大规模风电功率的不确定性,提出了将直流通道功率控制与互联系统内机械功率作为控制目标的互联系统暂态稳定的线性变参数鲁棒反馈控制方法,以提高经交直流风电通道互联的系统的暂态稳定性。针对互联系统暂态过程的强非线性特性,建立了线性变参数模型;根据暂态过程系统出现的功率差额和风电出力不确定度,将系统暂态过程设计为变参数的线性化模型。对线性变参数模型设计H∞鲁棒输出反馈控制器及其在线求解算法。根据线性变参数设计点和鲁棒控制器,提出了互联系统暂态稳定控制策略拓扑及传递函数。应用交直流联络线互联形成的4个等值电网互联系统进行数字仿真,结果表明,文章所提出线性变参数鲁棒反馈控制模型,具有较好的响应特性和暂态稳定控制效果。 相似文献
2.
3.
4.
5.
6.
7.
水轮机及其调节系统是水力发电系统中的重要组成部分,承担着能量转换的重要作用。水轮机运行于复杂工况下,往往表现出各种复杂的非线性行为,危害水力发电系统安全。基于刚性水击下混流式水轮机调节系统的数学模型,采用T-S模糊控制方法建立了水轮机调节系统的非线性T-S模糊模型,基于Lyapunov稳定性定理,提出了一种鲁棒控制策略,设计了相应的鲁棒控制器。仿真计算表明,所设计的鲁棒控制器能够极大地抑制水轮机调节系统的振荡,并在较短时间内将水轮机调节系统的运动控制到稳定运行状态,研究结果可为混流式水轮机调节系统的安全稳定运行控制提供参考依据。 相似文献
8.
9.
10.
11.
Clemens Jauch Syed M. Islam Poul Srensen Birgitte Bak Jensen 《Renewable Energy》2007,32(14):2334-2349
The design of a PID pitch angle controller for a fixed speed active-stall wind turbine, using the root locus method is described in this paper. The purpose of this controller is to enable an active-stall wind turbine to perform power system stabilisation. For the purpose of controller design, the transfer function of the wind turbine is derived from the wind turbine's step response. The performance of this controller is tested by simulation, where the wind turbine model with its pitch angle controller is connected to a power system model. The power system model employed here is a realistic model of the North European power system. A short circuit fault on a busbar close to the wind turbine generator is simulated, and the dynamic responses of the system with and without the power system stabilisation of the wind turbines are presented. Simulations show that in most operating points the pitch controller can effectively contribute to power system stabilisation. 相似文献
12.
The prospective of parameter space methods for robust control and an algorithm for a robust controller based on a pole-shifting adaptive control technique are presented in this paper for a hydroelectric turbine generator. Mathematical development of the robust adaptive controller algorithm, calculation procedure and results of simulation studies when applied to a water turbine governing system are described in this paper 相似文献
13.
Robust PID Controller Design for Hydroturbines 总被引:1,自引:0,他引:1
《Energy Conversion, IEEE Transaction on》2005,20(3):661-667
The design and analysis of a robust proportional, integral, derivative (PID) controller for a hydraulic turbine generator governor using a frequency-response technique is presented. The approach uses data from literature on the turbine and on the interconnected system in various modes of operation through a model in the literature to design a single PID controller to guarantee stability and performance over the entire operating range. To ensure stability of the loop for as yet unanticipated operating situations, gain margin, and phase margin, constraints are imposed during the design of the controller. The new PID governor is compared with a high-order controller designed by the$H_infty$ method. 相似文献
14.
为研究风气互补发电系统对电网的影响,首先搭建了由风电机组、燃气轮机、电网线路、静止无功补偿器、电力系统稳定器和大型水力发电机组成的仿真系统,并对该系统的负载侧和电网线路中部节点进行了稳定性分析。仿真结果表明,电网在加载了风气互补系统后运行能保持稳定,并能在发生短时故障后恢复到原来状态。该文为进一步研究风气互补系统与电网的相互影响提供了良好的模型基础。 相似文献
15.
水轮机调节系统被控对象模型辨识 总被引:1,自引:1,他引:1
建立了水轮机调节系统被控对象的非线性模型,用递推最小二乘法(RLS)对被控对象进行参数辨识。仿真实验证明,该模型与被控对象模型相吻合、过程简单、效果良好、易于实现编程。基于此对控制参数进行了优化,改善了系统的动态品质。具有实用价值。 相似文献
16.
This paper presents a design approach for a decentralized controller for a power plant. An electric power plant nonlinear model is decomposed into three subsystems: boiler, turbine, and generator. The interconnecting variables between the subsystems are treated as constant boundary conditions for the controller design. The local controllers are designed to be robust in order to accommodate fluctuations in the interaction variables once the overall system is considered. The drum pressure set-point is automatically obtained from the power demand through a functional mapping 相似文献
17.
Design of a low-cost micro-controller for a small induction-generator based grid-connected wind-turbine is presented in this paper. The controller senses the parameters of the wind-turbine generator and the grid, and makes decisions about grid connection and disconnection. Low-cost instrumentation circuitry has been developed to measure the generator and grid parameters. Based on the measurement of voltage and frequency of the wind-turbine generator and the grid side, a control decision is taken to connect the system to the grid. The controller makes decision to disconnect the system from the grid based on the power flow measurement between the wind turbine and the grid. The power flow between wind turbine and the grid depends upon the availability of the wind. The prototype controller has been developed based on a micro-controller PIC16F877 and has been tested in the laboratory. 相似文献
18.
《Renewable Power Generation, IET》2009,3(2):168-179
A robust pitch (RP) controller for variable-speed variable-pitch wind turbine generator systems (VSVPWTGS) is presented. The controller can not only level the wind energy conversion but also be applicable in a wide wind speed region even subject to large parametric or non-parametric disturbances. VSVP-WTGS consists of multi-subsystems with different time scales. The dominant `slow? dynamics are non-affine and high nonlinear. By considering `fast? subsystems as perturbations to the `slow? one, the dynamics of VSVP-WTGS can be represented by a nominal model and an error one. The RP controller is composed of a nominal inverse-system controller and a robust compensator. With the nominal inverse-system controller, the nominal closed-loop system can track its reference dynamics. With the robust compensator, turbine parameter uncertainties and non-parametric perturbations are tolerated. The performance of the RP controller is confirmed through theoretical analyses and computer simulations. Results show that RP controller can operate in a wider wind speed region robustly compared with a proportional-integral-derivative controller. Compared with other nonlinear controllers, the RP controller is simpler and can be more easily extended to other kinds of WTGS. 相似文献
19.
In the paper, the procedure is given for designing speed and active power controller of hydro turbine units. The procedure is based on mathematical models of the controlled system. The controller parameters are obtained from closed-loop poles and hydro turbine parameters by derived analytical formulas over a wide range of the hydro turbine operating points. The described procedure allows the fast and direct determination of the controller parameters. There is no need for heuristic controller parameters tuning. Results from two hydro turbine units with the controllers designed using the described procedure are given as an illustration. 相似文献
20.
调速器液压系统的故障诊断及可靠控制策略 总被引:8,自引:1,他引:7
在分析水轮机微机调速器液压随动系统失效机理的基础上,总结了系统基于专家知识的故障诊断方法,并提出了一种模型参考故障诊断方法.同时应用智能技术将故障诊断与相应的可靠控制策略结合起来,在故障诊断定位的基础上,通过控制策略的变化,消除或弱化故障的影响,达到保证机组安全的目的.仿真研究和工业应用实践充分证明了这些理论和方法的实用性、有效性和可靠性 相似文献