首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 840 毫秒
1.
Experimental heat transfer studies during evaporation of R-134a inside a corrugated tube have been carried out. The corrugated tube has been provided with different tube inclination angles of the direction of fluid flow from horizontal, α. The experiments were performed for seven different tube inclinations, α, in a range of − 90° to + 90° and four mass velocities of 46, 81, 110 and 136 kg m 2 s 1 for each tube inclination angle during evaporation of R-134a. Data analysis demonstrate that the tube inclination angle, α, affects the boiling heat transfer coefficient in a significant manner. The effect of tube inclination angle, α, on heat transfer coefficient, h, is more prominent at low vapor quality and mass velocity. In the low vapor quality region, the heat transfer coefficient, h, for the + 90° inclined tube is about 62% more than that of the − 90° inclined tube. The results also showed that at all mass velocities, the highest average heat transfer coefficient were achieved for α = + 90°. An empirical correlation has also been developed to predict the heat transfer coefficient during flow boiling inside a corrugated tube with different tube inclinations.  相似文献   

2.
The influence of nanoparticles on the flow-boiling of R-134a and R-134a/polyolester mixtures is quantified for flows of low vapor quality (x < 20%) over a range of mass fluxes (100 < G < 400 kg/m2 s). With direct dispersion of SiO2 nanoparticles in R-134a, the heat transfer coefficient decreases (as much as 55%) in comparison to pure R-134a. This degradation is, in part, due to difficulties in obtaining a stable dispersion. However, excellent dispersion is achieved for a mixture of R-134a and polyolester oil with CuO nanoparticles, and the heat transfer coefficient increases more than 100% over baseline R-134a/polyolester results. In the range of these experiments, nanoparticles have an insignificant effect on the flow pressure drop with the R-134a/POE/CuO nanofluid.  相似文献   

3.
An experiment is carried out here to investigate the characteristics of the evaporation heat transfer for refrigerants R-134a and R-407C flowing in horizontal small tubes having the same inside diameter of 0.83 or 2.0 mm. In the experiment for the 2.0-mm tubes, the refrigerant mass flux G is varied from 200 to 400 kg/m2 s, imposed heat flux q from 5 to 15 kW/m2, inlet vapor quality xin from 0.2 to 0.8 and refrigerant saturation temperature Tsat from 5 to 15 °C. While for the 0.83-mm tubes, G is varied from 800 to 1500 kg/m2 s with the other parameters varied in the same ranges as those for Di = 2.0 mm. In the study the effects of the refrigerant vapor quality, mass flux, saturation temperature and imposed heat flux on the measured evaporation heat transfer coefficient hr are examined in detail. The experimental data clearly show that both the R-134a and R-407C evaporation heat transfer coefficients increase almost linearly and significantly with the vapor quality of the refrigerant, except at low mass flux and high heat flux. Besides, the evaporation heat transfer coefficients also increase substantially with the rises in the imposed heat flux, refrigerant mass flux and saturation temperature. At low R-134a mass flux and high imposed heat flux the evaporation heat transfer coefficient in the smaller tubes (Di = 0.83 mm) may decline at increasing vapor quality when the quality is high, due to the partial dryout of the refrigerant flow in the smaller tubes at these conditions. We also note that under the same xin, Tsat, G, q and Di, refrigerant R-407C has a higher hr when compared with that for R-134a. Finally, an empirical correlation for the R-134a and R-407C evaporation heat transfer coefficients in the small tubes is proposed.  相似文献   

4.
The boiling heat transfer of refrigerant R-134a flow in horizontal small-diameter tubes with inner diameter of 0.51, 1.12, and 3.1 mm was experimentally investigated. Local heat transfer coefficient and pressure drop were measured for a heat flux ranging from 5 to 39 kW/m2, mass flux from 150 to 450 kg/m2 s, evaporating temperature from 278.15 to 288.15 K, and inlet vapor quality from 0 to 0.2. Flow patterns were observed by using a high-speed video camera through a sight glass at the entrance of an evaporator. Results showed that with decreasing tube diameter, the local heat transfer coefficient starts decreasing at lower vapor quality. Although the effect of mass flux on the local heat transfer coefficient decreased with decreasing tube diameter, the effect of heat flux was strong in all three tubes. The measured pressure drop for the 3.1-mm-ID tube agreed well with that predicted by the Lockhart–Martinelli correlation, but when the inner tube diameter was 0.51 mm, the measured pressure drop agreed well with that predicted by the homogenous pressure drop model. With decreasing tube diameter, the flow inside a tube approached homogeneous flow. The contribution of forced convective evaporation to the boiling heat transfer decreases with decreasing the inner tube diameter.  相似文献   

5.
An experiment is carried out here to investigate the evaporation heat transfer and associated evaporating flow pattern for refrigerant R-134a flowing in a horizontal narrow annular duct. The gap of the duct is fixed at 1.0 and 2.0 mm. In the experiment, the effects of the duct gap, refrigerant vapor quality, mass flux and saturation temperature and imposed heat flux on the measured evaporation heat transfer coefficient hr are examined in detail. For the duct gap of 2.0 mm, the refrigerant mass flux G is varied from 300 to 500 kg/m2 s, imposed heat flux q from 5 to 15 kW/m2, vapor quality xm from 0.05 to 0.95, and refrigerant saturation temperature Tsat from 5 to 15 °C. While for the gap of 1.0 mm, G is varied from 500 to 700 kg/m2 s with the other parameters varied in the same ranges as that for δ = 2.0 mm. The experimental data clearly show that the evaporation heat transfer coefficient increases almost linearly with the vapor quality of the refrigerant and the increase is more significant at a higher G. Besides, the evaporation heat transfer coefficient also rises substantially at increasing q. Moreover, a significant increase in the evaporation heat transfer coefficient results for a rise in Tsat, but the effects are less pronounced in the narrower duct at a low imposed heat flux and a high refrigerant mass flux. Furthermore, the evaporation heat transfer coefficient increases substantially with the refrigerant mass flux except at low vapor quality. We also note that reducing the duct gap causes a significant increase in hr. In addition to the heat transfer data, photos of R-134a evaporating flow taken from the duct side show the change of the dominant two-phase flow pattern in the duct with the experimental parameters. Finally, an empirical correlation for the present measured heat transfer coefficient for the R-134a evaporation in the narrow annular ducts is proposed.  相似文献   

6.
This paper presents an experimental investigation of laminar film condensation of R134a in a vertical smooth tube having an inner diameter of 7–8.1 mm and a length of 500 mm. Condensation experiments were performed at mass fluxes of 29 and 263 kg m?2 s?1. The pressures were between 0.77 and 0.1 MPa. The heat transfer coefficient, film thickness and condensation rate during downward condensing film were determined. The results show that an interfacial shear effect is significant for the laminar condensation heat transfer of R134a under the given conditions. A new correlation for the condensation heat transfer coefficient is proposed for practical applications.  相似文献   

7.
In this paper, flow patterns and their transitions for refrigerant R-134a condensing in a microfin tube are visually observed and analyzed. The microfin tube has been provided with different tube inclination angles of the direction of fluid flow from horizontal, α. The experiments were performed for seven different tube inclinations, α, in a range of − 90° to + 90° and refrigerant mass velocities in a range of 53 to 212 kg/m2s for each tube inclination angle during condensation of R-134a vapor. From analysis of acquired data, it was found that the tube inclination strongly influenced the vapor and condensate liquid distribution. Annular flow was the dominant flow pattern for vertical downward flow, α = − 90°. Annular flow, semi annular flow and stratified flow were observed for α = − 60°and − 30°. Annular flow, wavy-annular flow and stratified-wavy flow exist in sequence for horizontal tube. Annular flow and wavy-annular flow were observed for α = + 30°and + 60°. Annular flow, annular-wavy flow, churn flow and slug flow occurred for α = + 90°.  相似文献   

8.
This experimental study is performed to investigate condensation heat transfer coefficient of R-134a flow inside corrugated tube with different inclinations. Different inclinations of test condenser ranging from − 90° to + 90° and various flow mass velocities in the range of 87 to 253 [kg/m2s] are considered in this study. Data analysis showed that change in the tube inclination had a significant effect on condensation heat transfer behavior. At low mass velocities, and low vapor qualities, the highest condensation heat transfer coefficient was obtained for α = + 30° which was 1.41 times greater than the least one obtained for α = − 90°. The results also showed that at all mass velocities, the highest average heat transfer coefficients were achieved for α = + 30°. Based on the experimental results, a new empirical correlation is proposed to predict the condensation heat transfer coefficient of R134a flow in corrugated tubes with different inclinations.  相似文献   

9.
An experimental study of convective condensation of R134a in an 8.38 mm inner diameter smooth tube in inclined orientations is presented. This article, being the first of a two-part paper (the second part concentrates on the pressure drops and void fractions), presents flow patterns and heat transfer coefficients during condensation for different mass fluxes and vapour qualities for the whole range of inclination angles (from vertical downwards to vertical upwards). The results were compared with three flow pattern maps available in literature. It was found that for low mass fluxes and/or low vapour qualities, the flow pattern is strongly dependent on the inclination angle whereas it remains annular for high mass fluxes and high vapour qualities, whatever the tube orientation. The models of flow pattern maps available in the literature did not predict the experimental data well. In the inclination-dependent zone, experiments showed that there is an optimum inclination angle that leads to the highest heat transfer coefficient for downward flow. The heat transfer coefficient is strongly affected by the liquid and vapour distributions and especially by the liquid thickness at the bottom of the tube for stratified flows. Thus developing a mechanistic model of flow pattern maps is the first step in achieving a predictive tool for the heat transfer coefficient in convective condensation in inclined tubes.  相似文献   

10.
This paper presents experimentally determined heat transfer coefficients for condensation from a superheated vapor of CO2 and R410A. The superheated vapor was flowed through a smooth horizontal tube with 6.1 mm ID under almost uniform temperature cooling at reduced pressures from 0.55 to 0.95, heat fluxes from 3 to 20 kW m?2, and superheats from 0 to 40 K. When the tube wall temperature reaches the saturation point, the measured results show that the heat transfer coefficient gradually starts deviating from the values predicted by a correlation valid for single-phase gas cooling. This point identifies the start of condensation from the superheated vapor. The condensation starts earlier at higher heat fluxes because the tube wall temperature reaches the saturation point earlier. The heat transfer coefficient reaches a value predicted by correlations for condensation at a thermodynamic vapor quality of 1. The measured heat transfer coefficient of CO2 is roughly 20–70% higher than that of R410A at the same reduced pressures. This is mainly because the larger latent heat and liquid thermal conductivity of CO2, compared to that of R410A, increase the heat transfer coefficient.  相似文献   

11.
An empirical setup has been established to study heat transfer and pressure drop characteristics during condensation of R600a, a hydrocarbon refrigerant, in a horizontal plain tube and different flattened channels. Round copper tubes of 8.7 mm I.D. were deformed into flattened channels with different interior heights of 6.7 mm, 5.2 mm and 3.1 mm as test sections. The test conditions include heat flux of 17 kw/m2, mass velocity in the range of 154.8–265.4 kg/m2s and vapor quality variation from approximately 10% to 80%. Results indicate that flattening the tubes causes significant enhancement of heat transfer coefficient which is also accompanied by simultaneous augmentation in flow pressure drop. Therefore, the overall performance of the flattened tubes with respect to heat transfer enhancement considering the pressure drop penalty is analyzed. It is concluded that the flattened tube with 5.2 mm inner height tube has the best overall performance. Due to the failure of pre-existing correlations for round tube condensation heat transfer, a new correlation is proposed which predicts 90% of the entire data within ± 17% error.  相似文献   

12.
An experimental investigation has been carried out to study the effect of twisted tape inserts on heat transfer enhancement and pressure drop in a horizontal tube during swirl flow boiling of R-134a. The test-evaporator was an electrically heated horizontal copper tube and twisted tapes with different twist ratios of 6, 9, 12 and 15 were inserted one by one. The data were acquired at the refrigerant mass velocities of 54, 86, 114 and 136 kg/s m2. The twisted tape inserts increases the boiling heat transfer coefficients and the pressure drop across the test-evaporator. An empirical correlation has also been developed to predict the swirl flow pressure drop in the test-evaporator.  相似文献   

13.
An experimental investigation has been conducted to clarify forced convection heat transfer characteristic and flow behavior of an isothermal cam shaped tube in cross flow. The range of angle of attack and Reynolds number based on an equivalent circular tube are within 0° < α < 180° and 1.5 × 104 < Reeq < 2.7 × 104, respectively.The results show that the mean heat transfer coefficient is a maximum at about α = 90° over the whole range of the Reynolds numbers. It is found that thermal hydraulic performance of the cam shaped tube is larger than that of a circular tube with the same surface area except for α = 90° and 120°. Furthermore, the effect of the diameter of the cam shaped tube upon the thermal hydraulic performance is discussed.  相似文献   

14.
In this paper an experimental study of convective boiling heat transfer of R-600a/oil/nanoparticle mixtures is investigated. The experimental setup was prepared with a smooth horizontal tube as a test section with the length and diameter of 9.5 and 103 mm, respectively, and pure R-600a was applied for evaluating the heat transfer enhancement. Six mixtures containing 1% weight fraction of R-600a/oil with different concentrations of CuO nanoparticles including 0.0, 0.5, 1.0, 1.5, 2.0 and 5.0% weight fraction of R-600a/oil/nanoparticle were used in our study.The mass velocity per cross area was considered at the range of 50–700 kg/m2 s for low vapor quality (ϕ < 0.25). The results showed that the convective boiling heat transfer coefficient will be increased by increasing the mass fraction of nanoparticles up to 2%, while by increasing the mass fraction of nanoparticles up to 5% the heat transfer coefficient will be reduced.  相似文献   

15.
An experimental study on in-tube flow boiling heat transfer of R-134a/R-290/R-600a refrigerant mixture has been carried out under varied heat flux test conditions. The heat transfer coefficients are experimentally measured at temperatures between ?8 and 5 °C for mass flow rates of 3–5 g s?1. Acetone is used as a hot fluid which flows in the outer tube of diameter 28.57 mm while the refrigerant mixture flows in the inner tube of diameters 9.52 and 12.7 mm. By regulating the acetone flow conditions, the heat flux is maintained between 2 and 8 kW/m2 and the pressure of the refrigerant is maintained between 3.2 and 5 bar. The comparison of experimental results with the familiar correlations shows that the correlations over predict the heat transfer coefficients for this mixture when stratified and stratified-wavy flow prevail. Multiple regression technique is used to evolve and modify existing correlations to predict the heat transfer coefficient of the refrigerant mixture. It is found that the modified version of Lavin–Young correlation (1965) predicts the heat transfer coefficient of the considered mixture within an average deviation of ±20.5 %.  相似文献   

16.
This paper presents the results of an investigation of the influence of hydrodynamic instabilities on heat transfer intensity during the condensation of R134a and R404A refrigerants in pipe mini-channels. The heat transfer coefficient h is a measure of the effectiveness of the condensation process. It is particularly important to determine the value of the coefficient in the two-phase condensation area in a compact condenser. In other condenser areas (i.e., precooling of superheated vapor and subcooling of condensate), the heat efficiency is substantially smaller. Hydrodynamic instabilities of a periodic nature have an influence on size changes in these areas. A decrease in the heat transfer coefficient h in the two-phase area results in decreased intensity of the heat removal process in the whole condenser.The experimental investigations were based on the condensation of R134a and R404A refrigerants in horizontal pipe mini-channels with internal diameters of d = 0.64; 0.90; 1.40; 1.44; 1.92; 2.30 and 3.30 mm. Disturbances of the condensation process were induced with a periodic stop and a repetition of the flow of the refrigerant.In the range of frequencies, f = 0.25–5 Hz, of the periodically generated disturbances, an unfavorable influence on the intensity of the heat transfer during the condensation process in pipe mini-channels was identified. The reduction in the intensity of the heat transfer during the condensation process, which was induced with hydrodynamic instabilities, was presented in the form of the dependence of the heat transfer coefficient h on the vapor quality x and the frequencies f of the disturbances.The influence of the refrigerant, the diameter of the mini-channels and the frequency f on the damping phenomenon of the periodical disturbances in the pipe mini-channels was identified.  相似文献   

17.
The current paper presents experimental investigation of nucleate pool boiling of R-134a and R-123 on enhanced and smooth tubes. The enhanced tubes used were TBIIHP and TBIILP for R-134a and R-123, respectively. Pool boiling data were taken for smooth and enhanced tubes in a single tube test section. Data were taken at a saturation temperature of 4.44 °C. Each test tube had an outside diameter of 19.05 mm and a length of 1 m. The test section was water heated with an insert in the water passage. The insert allowed measurement of local water temperatures down the length of the test tube. Utilizing this instrumentation, local heat transfer coefficients were determined at five locations along the test tube. The heat flux range was 2.5–157.5 kW/m2 for the TBIIHP tube and 3.1–73.2 kW/m2 for the TBIILP tube. The resulting heat transfer coefficient range was 4146–23255 W/m2. °C and 5331–25950 W/m2. °C for both tubes, respectively. For smooth tube testing, the heat flux ranges were 7.3–130.7 kW/m2 and 7.5–60.7 kW/m2 for R-134a and R-123, respectively; with resulting heat transfer coefficient ranges of 1798.9–11,379 W/m2. °C and 535.4–3181.8 W/m2. °C. The study provided one of the widest heat flux ranges ever examined for these types of tubes and showed significant structure to the pool boiling curve that had not been traditionally observed. Additionally, this paper presented an investigation of enhanced tubes pool boiling models.  相似文献   

18.
The present paper describes the results of experimental investigations of heat transfer and pressure drop during the condensation of the R134a and R404A refrigerants in pipe minichannels with internal diameters d = 0.31–3.30 mm. The results concern investigations of the local heat transfer coefficient and a pressure drop in single mini-channels. The results were compared with calculations according to the correlations proposed by other authors. Within the range of the examined parameters of the condensation process in mini-channels produced from stainless steel, it was established that the values of the heat transfer coefficient may be described with Akers et al. and Shah correlations within a limited range of the mass flux density of the refrigerant and the mini-channel diameter. A pressure drop during the condensation of these refrigerants is described in a satisfactory manner with Friedel and Garimella correlations. On the basis of the experimental investigations, the authors proposed their own correlation for the calculation of local heat transfer coefficient αx.  相似文献   

19.
The present study presents new flow boiling heat transfer results of R-134a flowing inside a 13.84 mm internal diameter, smooth horizontal copper tube. The heat transfer measurements were made over a wide range of test conditions: saturation temperatures of 5, 15 and 20 °C, (corresponding to reduced pressures of 0.08, 0.12 and 0.14), vapor qualities ranged from 0.01 to 0.99, mass velocities of 300 and 500 kg/m2 s, and heat fluxes of 7.5 and 17.5 kW/m2. The experimental results clearly show that a local minimum heat transfer coefficient systematically occurs within slug flow pattern or near the slug-to-intermittent flow pattern transition. The vapor quality xmin at which the local minimum occurs seems to be primarily sensitive to mass velocity and heat flux. Thus, it is influenced by the competition between nucleate and convective boiling mechanisms that control macroscale flow boiling. The experimental results were compared to four types of predictive methods: (a) strictly convective, (b) superposition, (c) strictly empirical and (d) flow pattern based. Generally, all the methods tend to underpredict the experimental data and the higher errors occur in two particular regions: low and high vapor qualities. These vapor qualities correspond to slug and annular patterns, respectively. For slug flow, methods that require the identification of nucleate boiling related regions tend to predict the heat transfer coefficient accurately. This emphasizes that for slug flows, heat transfer is not a simple juxtaposition of nucleate and convective boiling contributions, but that the integration of these two heat transfer mechanisms is also a function of flow parameters. The comparisons between experimental and predicted data show that the best overall results are obtained with superposition and flow pattern based methods.  相似文献   

20.
Free convection from the inside surface of vertical and inclined elliptic tubes of axis ratio (a:b) 2:1 with a uniformly heated surface (constant heat flux) is investigated experimentally. The effects of orientation angle (α) and inclination angle (ϕ) on the heat transfer coefficient were studied. The orientation angle (α) is varied from 0° (when the major axis is horizontal) to 90° (when the major axis is vertical) with steps of 15°. The inclination angle (ϕ) is measured from the horizontal and varied from 15° to 75° with steps of 15°. The vertical position is considered as a special case of the inclined case when ϕ = 90. The experiments covered a range of Rayleigh number, Ra from 2.6 × 106 to 3.6 × 107. The local and average Nusselt numbers are estimated for different orientation angles and inclination angles at different Rayleigh numbers. The results obtained showed that the local Nu increased with the increase of axial distance from the lower end of the elliptic tube until a maximum value near the upper end, and then, it gradually decreased. The average Nu increases with the increase of α or ϕ at the same Ra. The results obtained are correlated by dimensionless groups and with the available data of the inclined and vertical elliptic tubes.  相似文献   