首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Experiments are conducted here to investigate how the channel size affects the subcooled flow boiling heat transfer and associated bubble characteristics of refrigerant R-134a in a horizontal narrow annular duct. The gap of the duct is fixed at 1.0 and 2.0 mm in this study. From the measured boiling curves, the temperature undershoot at ONB is found to be relatively significant for the subcooled flow boiling of R-134a in the duct. The R-134a subcooled flow boiling heat transfer coefficient increases with a reduction in the gap size, but decreases with an increase in the inlet liquid subcooling. Besides, raising the imposed heat flux can cause a substantial increase in the subcooled boiling heat transfer coefficient. However, the effects of the refrigerant mass flux and saturated temperature on the boiling heat transfer coefficient are small in the narrow duct. Visualization of the subcooled flow boiling processes reveals that the bubbles are suppressed to become smaller and less dense by raising the refrigerant mass flux and inlet subcooling. Moreover, raising the imposed heat flux significantly increases the bubble population, coalescence and departure frequency. The increase in the bubble departure frequency by reducing the duct size is due to the rising wall shear stress of the liquid flow, and at a high imposed heat flux many bubbles generated from the cavities on the heating surface tend to merge together to form big bubbles. Correlation for the present subcooled flow boiling heat transfer data of R-134a in the narrow annular duct is proposed. Additionally, the present data for some quantitative bubble characteristics such as the mean bubble departure diameter and frequency and the active nucleation site density are also correlated.  相似文献   

2.
Subcooled flow boiling heat transfer characteristics of refrigerant R-134a in a vertical plate heat exchanger (PHE) are investigated experimentally in this study. Besides, the associated bubble characteristics are also inspected by visualizing the boiling flow in the vertical PHE. In the experiment two vertical counterflow channels are formed in the exchanger by three plates of commercial geometry with a corrugated sinusoidal shape of a chevron angle of 60°. Upflow boiling of subcooled refrigerant R-134a in one channel receives heat from the downflow of hot water in the other channel. The effects of the boiling heat flux, refrigerant mass flux, system pressure and inlet subcooling of R-134a on the subcooled boiling heat transfer are explored in detail. The results are presented in terms of the boiling curves and heat transfer coefficients. The measured data showed that the slopes of the boiling curves change significantly during the onset of nucleate boiling (ONB) especially at low mass flux and high saturation temperature. Besides, the boiling hysteresis is significant at a low refrigerant mass flux. The subcooled boiling heat transfer coefficient is affected noticeably by the mass flux of the refrigerant. However, increases in the inlet subcooling and saturation temperature only show slight improvement on the boiling heat transfer coefficient.The photos from the flow visualization reveal that at higher imposed heat flux the plate surface is covered with more bubbles and the bubble generation frequency is substantially higher, and the bubbles tend to coalesce to form big bubbles. But these big bubbles are prone to breaking up into small bubbles as they move over the corrugated plate, producing strong agitating flow motion and hence enhancing the boiling heat transfer. We also note that the bubbles nucleated from the plate are suppressed to a larger degree for higher inlet subcooling and mass flux. Finally, empirical correlations are proposed to correlate the present data for the heat transfer coefficient and the bubble departure diameter in terms of boiling, Froude, Reynolds and Jakob numbers.  相似文献   

3.
The present paper reports the results of a visualization study of the burnout in subcooled flow boiling of water, with square cross section annular geometry (formed by a central heater rod contained in a duct characterized by a square cross section). The coolant velocity is in the range 3–10 m/s. High speed movies of flow pattern in subcooled flow boiling of water from the onset of nucleate boiling up to physical burnout of the heater are recorded. From video images (single frames taken with a stroboscope light and an exposure time of 1 μs), the following general behaviour of vapour bubbles was observed: when the rate of bubble generation is increasing, with bubbles growing in the superheated layer close to the heating wall, their coalescence produces a type of elongated bubble called vapour blanket. One of the main features of the vapour blanket is that it is rooted to the nucleation site on the heated surface. Bubble dimensions are given as a function of thermal-hydraulic tested conditions for the whole range of velocity until the burnout region. A qualitative analysis of the behaviour of four stainless steel heater wires with different macroscopic surface finishes is also presented, showing the importance of this parameter on the dynamics of the bubbles and on the critical heat flux.  相似文献   

4.
We have developed a stabilizer of the temperature of a thermoresistor wire electric heater based on a PID controller. Using this stabilizer, we investigated heat exchange of subcooled water in pool boiling. We found that on stabilization of the heater temperature up to that of the subcooled water, transition from convection to the regime of bubble boiling and vice versa occurs spontaneously and is accompanied by a jumpwise change in heat transfer. It is shown that in the regime of stable bubble boiling, the law of heat transfer is independent of the liquid temperature and the heater diameter and that the maximum heat loading may attain 50 MW/m2, which is much above the values cited earlier in the literature. Based on the results obtained, a mechanism of implementation of bubble boiling for the regimes of a constant heat flux and a constant temperature is suggested. The assumption is made that the regime of heterogeneous vapour generation is possible only in the case of the heater constant temperature. In the regime of a stabilized heat flux on the heater, the spatially inhomogeneous regime of heat transfer is established. This regime represents a spatially distributed combination of three regimes: convective heat transfer, homogeneous boiling, manifesting itself in periodic boiling-up of overheated layers of the liquid near the surface and an unstable regime of heterogeneous vapour generation.  相似文献   

5.
Bubble growth behavior and heat transfer characteristics during subcooled flow boiling in segmented finned microchannels have been numerically investigated. Simulations have been performed for a single row of segmented finned microchannel and predicted results are compared with experimental investigations. Onset of nucleation, formation of bubbles, their growth and movements have been investigated for different values of applied heat flux. Mechanism of bubble expansion without clogging resulting in enhanced heat transfer in segmented finned microchannels has been explained. Temperature and pressure fluctuations during subcooled flow boiling condition have been investigated. It is observed that at high heat flux, thin liquid film trapped between the bubble and channel wall is evaporated leading to localized heating effect. Predicted flow patterns are similar to experimental results. However, simulations over predict the bubble growth rate and heat transfer coefficient.  相似文献   

6.
A photographic study was carried out for the subcooled flow boiling of water to elucidate the rise characteristics of single vapor bubbles after the departure from nucleation sites. The test section was a transparent glass tube of 20 mm in inside diameter and the flow direction was vertical upward; liquid subcooling was parametrically changed within 0–16 K keeping system pressure and liquid velocity at 120 kPa and 1 m/s, respectively. The bubble rise paths were analyzed from the video images that were obtained at the heat flux slightly higher than the minimum heat flux for the onset of nucleate boiling. In the present experiments, all the bubbles departed from their nucleation sites immediately after the inception. In low subcooling experiments, bubbles slid upward and consequently were not detached from the vertical heated wall; the bubble size was increased monotonously with time in this case. In moderate and high subcooling experiments, bubbles were detached from the wall after sliding for several millimeters and migrated towards the subcooled bulk liquid. The bubbles then reversed the direction of lateral migration and were reattached to the wall at moderate subcooling while they collapsed due to the condensation at high subcooling. It was hence considered that the mechanisms of the heat transfer from heated wall and the axial growth of vapor volume were influenced by the difference in bubble rise path. It was observed after the inception that bubbles were varied from flattened to more rounded shape. This observation suggested that the bubble detachment is mainly caused by the change in bubble shape due to the surface tension force.  相似文献   

7.
Wall boiling and bubble population balance equations combined with a two-fluid model are employed to predict boiling two-phase flow in an inclined channel with a downward-facing heated upper wall. In order to observe the boiling behavior on the inclined, downward-facing heated wall, a visualization experiment was carried out with a 100 mm × 100 mm of the cross section, 1.2-m-long rectangular channel, inclined by 10° from the horizontal plane. The size of the heated wall was 50 mm by 750 mm and the heat flux was provided by Joule heating using DC electrical current. The temperatures of the heater surface were measured and used in calculating heat transfer coefficients. The wall superheat for 100 kW/m2 heat flux and 200 kg/m2s mass flux ranged between 9.3°C and 15.1°C. High-speed video images showed that bubbles were sliding, continuing to grow, and combining with small bubbles growing at their nucleation sites in the downstream. Then large bubbles coalesced together when the bubbles grew too large to have a space between them. Finally, an elongated slug bubble formed and it continued to slide along the heated wall. For these circumstances of wall boiling and two-phase flow in the inclined channel, the existing wall boiling model encompassing bubble growth and sliding was improved by considering the influence of large bubbles near the heated wall and liquid film evaporation under the large slug bubbles. With this improved model, the predicted wall superheat agreed well with the experimental data, while the RPI model largely overpredicted the wall superheat.  相似文献   

8.
An experiment is conducted here to investigate how the channel size affects the subcooled flow boiling heat transfer and the associated bubble characteristics of refrigerant R-407C in a horizontal narrow annular duct with the gap of the duct fixed at 1.0 and 2.0 mm. The measured boiling curves indicate that the temperature overshoot at ONB is relatively significant for the subcooled flow boiling of R-407C in the duct. Besides, the subcooled flow boiling heat transfer coefficient increases with a reduction in the duct gap, but decreases with an increase in the inlet liquid subcooling. Moreover, raising the heat flux imposed on the duct can cause a significant increase in the boiling heat transfer coefficients. However, the effects of the refrigerant mass flux and saturated temperature on the boiling heat transfer coefficient are slighter. Visualization of the subcooled flow boiling processes in the duct reveals that the bubbles are suppressed to become smaller and less dense by raising the refrigerant mass flux and inlet subcooling. Raising the imposed heat flux, however, produces positive effects on the bubble population, coalescence and departure frequency. Meanwhile, the present heat transfer data for R-407C are compared with the R-134a data measured in the same duct and with some existing correlations. We also propose empirical correlations for the present data for the R-407C subcooled flow boiling heat transfer and some quantitative bubble characteristics such as the mean bubble departure diameter and frequency and the active nucleation site density.  相似文献   

9.
Zhen Sun  Xiaodan Chen 《传热工程》2018,39(7-8):663-671
Surfaces with spatial wettability patterns have been proven to enhance heat transfer coefficient and critical heat flux in pool boiling. To understand the physical mechanism behind this phenomenon and obtain the correlation among some critical parameters (bubble departure frequency, bubble size, nucleation site density, surface tension), pool boiling experiments were conducted. A Pyrex glass with a layer of indium-tin-oxide was used as the substrate. Hydrophobic patterns will serve as nucleation sites. Experiments were conducted in deionized water under atmospheric pressure at a relatively low heat flux. The processes of nucleation, growth, and departure of individual bubbles were visualized by using a high speed camera through the bottom of the heater surface. It has been found that the patterned surface performed the best in heat transfer for subcooled pool boiling when compared with hydrophilic and hydrophobic surfaces. The nucleation site density of the biphilic surface was much higher, when compared with that of the homogeneous surface. The individual bubbles always nucleate on the edge of the hydrophobic and hydrophilic area, and then move onto the hydrophobic pattern. Most of the individual bubbles detach from the wettability patterned surface in the diameter range from 300 µm to 450 µm (around 77.3%). The bubble departure periods scatter in the range from 80 ms to 1500 ms.  相似文献   

10.
Nucleate boiling heat transfer and bubble dynamics in a thin liquid film on a horizontal rotating disk were studied. A series of experiments were conducted to determine the heat transfer coefficient on the disk. At low rotation and flow rates, vigorous boiling increased the heat transfer coefficients above those without boiling. Higher rotational speeds and higher flow rates increased the heat transfer coefficient and suppressed boiling by decreasing the superheat in the liquid film. The flow field on the disk, which included supercritical (thin film) flow upstream of a hydraulic jump, and subcritical (thick film) flow downstream of a hydraulic jump, affected the type of bubble growth. Three types of bubble growth were identified. Vigorous boiling with large, stationary bubbles were observed in the subcritical flow. Supercritical flow produced small bubbles that remained attached to the disk and acted as local obstacles to the flow. At low rotational rates, the hydraulic jump that separated the supercritical and subcritical regions produced hemispherical bubbles that protruded out of the water film surface and detached from the disk, allowing them to slide radially outward. A model of the velocity and temperature of the microlayer of water underneath these sliding bubbles indicated that the microlayer thickness was approximately 1/25th of that of the surrounding water film. This microlayer is believed to greatly enhance the heat transfer rate underneath the sliding bubbles.  相似文献   

11.
12.
Improved wall heat flux partitioning accounting sliding bubbles and a mechanistic model that incorporates the fundamental consideration of bubble frequency during low-pressure subcooled flow boiling is presented. A model considering the forces acting on departing bubbles at the heated surface is employed. Coupled with a three-dimensional two-fluid and population balance equations based on the modified MUSIG (MUltiple-SIze-Group) model, the behavior of an upward forced convective subcooled boiling flows in a vertical annular channel is simulated. Comparison of model predictions against local and axial measurements (heat fluxes ranged from 152.9 to 705.0 kW/m2) is made for the void fraction, Sauter mean bubble diameter and interfacial area concentration covering a range of different mass and heat fluxes and inlet subcoolings. Good agreement is achieved between the predicted and measured profiles. Reasonable agreement with recent experimental measurements is also attained for the predicted growth and waiting times of bubble frequency at particular local wall superheat and subcooling temperatures.  相似文献   

13.
Heat removal of more than 10 MW/m2 in heat flux has been required in high‐heat‐generation equipment in nuclear fusion reactors. In some conditions of water subcooling and velocity, there appears an extraordinary high heat flux boiling in the transition boiling region. This boiling regime is called micro‐bubble emission boiling (MEB) because many micro‐bubbles are spouted from the heat transfer surface accompanying a huge sound. The study intent is to obtain heat transfer performance of MEB in horizontal and vertical heated surfaces to parallel flow of subcooled water, comparing with CHF of this system. Three types of MEB with different heat transfer performance and bubble behavior are observed according to the flow velocity and liquid subcooling. © 2003 Wiley Periodicals, Inc. Heat Trans Asian Res, 32(2): 130–140, 2003; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.10077  相似文献   

14.
Heat transfer associated with a vapor bubble sliding along a downward-facing inclined heater surface was studied experimentally using holographic interferometry. Volume growth rate of the bubbles as well as the rate of heat transfer along the bubble interface were measured to understand the mechanisms contributing to the enhancement of heat transfer during sliding motion. The heater surface was made of polished silicon wafer (length 185 mm and width 49.5 mm). Experiments were conducted with PF-5060 as test liquid, for liquid subcoolings ranging from 0.2 to 1.2 °C and wall superheats from 0.2 to 0.8 °C. The heater surface had an inclination of 75° to the vertical. Individual vapor bubbles were generated in an artificial cavity at the lower end of the heater surface. High-speed digital photography was used to measure the bubble growth rate. The temperature field around the sliding bubble was measured using holographic interferometry. Heat transfer at the bubble interface was calculated from the measured temperature field. Results show that for the range of parameters considered the bubbles continued to grow, with bubble growth rates decreasing with increasing liquid subcooling. Heat transfer measurements show that condensation occurs on most of the bubble interface away from the wall. For the parameters considered condensation accounted for less than 12% of the rate heat transfer from the bubble base. In this study the heater surface showed no drop in temperature as a result of heat transfer enhancement during bubbles sliding.  相似文献   

15.
In order to develop a mechanistic model for the subcooled flow boiling process, the key issues which must be addressed are wall heat flux partitioning and interfacial (condensation) heat transfer. The sink term in the two-fluid models for void fraction prediction is provided by the condensation rate at the vapor-liquid interface. Low pressure subcooled flow boiling experiments, using water, were performed using a vertical flat plate heater to investigate the bubble collapse process. A high-speed CCD camera was used to record the bubble collapse in the bulk subcooled liquid. Based on the analyses of these digitized images, bubble collapse rates and the associated heat transfer rate were determined. The experimental data were in turn used to correlate the bubble collapse rate and the interfacial heat transfer rate. These correlations are functions of bubble Reynolds number, liquid Prandtl number, Jacob number, and Fourier number. The correlations account for both the effect of forced convection heat transfer and thickening of the thermal boundary layer as the vapor bubble condenses which in turn makes the condensation heat transfer time dependent. Comparison of the measured experimental data with those predicted from the correlations show that predictions are well within ±25% of the experimentally measured values. These correlations have also been compared with those available in the literature.  相似文献   

16.
A new mechanism model for determination of the critical heat flux (CHF) in subcooled impingement boiling on the stagnation zone is proposed in this paper. It is based on the combination of the Helmholtz instability theory of macrolayer and the model of bubble induced turbulent heat transfer in subcooled impingement boiling. A semi-theoretical and semi-empirical correlation and its nondimensional form of the CHF for subcooled jet impingement boiling on the stagnation zone are also derived. Under the circumstances of CHF, the bubble induced turbulent heat transfer coefficient gets doubled as compared to the single-phase laminar heat transfer coefficient according to the theoretical model and the experimental data. And this kind of bubble induced turbulent heat transfer enhancing effect can be considered as a fixed ratio. The theoretical analysis result for the present case is successfully verified by the experimental result obtained on the smooth heating surface. Through the discussions, it is obtained that the CHF ratio of the subcooled jet impingement boiling against the saturated jet impingement boiling is theoretically related to the surface condition of the heater and the properties and impact velocity of the working fluid.  相似文献   

17.
It has been considered that dry-out occurs easily in boiling heat transfer for a small channel, a mini- or microchannel, because the channel was easily filled with coalescing vapor bubbles. In the present study, the experiments of subcooled flow boiling of water were performed under atmospheric conditions for a horizontal rectangular channel for which the size is 1 mm height and 1 mm width, with a flat heating surface of 10 mm length and 1 mm width placed on the bottom of the channel. The heating surface has a top of copper heating block and is heated by ceramic heaters. In the high heat flux region of nucleate boiling, about 70–80% of the heating surface was covered with a large coalescing bubble and the boiling reached critical heat flux as observed by high-speed video. In the beginning of transition boiling, coalescing bubbles were collapsed to many fine bubbles and microbubble emission boiling was observed at liquid subcooling higher than 30 K. The maximum heat flux obtained was 8 MW/m2 (800 W/cm2) at liquid subcooling of higher than 40 K and a liquid velocity of 0.5 m/s. However, the surface temperature was very much higher than that of a centimeter-scale channel. The high-speed video photographs indicated that microbubble emission boiling occurs in the deep transition boiling region.  相似文献   

18.
Ke Wang  Shengjie Gong  Bofeng Bai 《传热工程》2013,34(17-18):1498-1506
ABSTRACT

It is traditionally accepted that the critical heat flux (CHF) decreases with increasing nucleation site density (NSD). However, such a CHF-NSD relation was no longer observed in the BETA-B experiment performed on nano-film heaters; instead the increase of NSD resulted in a gain in CHF. To address this seeming contradiction in the relation between critical heat flux and nucleation site density, the present work employed probabilistic analysis to reveal the different tendencies. A concept of effective NSD was proposed, which concerns the active nucleation sites appear within a bubble lifetime, and the resulting bubbles have the chance of direct interaction. We assumed that the boiling crisis on a heater surface is mainly induced by two mechanisms: dry spot expanding in isolated bubble regime for low-NSD surface, coalescence of dry spots under multiple bubbles in fully developed nucleate boiling regime for high-NSD surface, or a combination of the two in the transition regime for medium-NSD surface. Accordingly, we estimated the critical heat flux of each boiling regime at which the boiling crisis occurs. The result indicated that there is a threshold of nucleation site density below which the increase of NSD is contributing to CHF enhancement, while the trend is inverted beyond the threshold.  相似文献   

19.
Experiments are conducted here to investigate how the channel size affects the saturated flow boiling heat transfer and associated bubble characteristics of refrigerant R-134a in a horizontal narrow annular duct. The gap of the duct is fixed at 1.0 and 2.0 mm in this study. The measured heat transfer data indicate that the saturated flow boiling heat transfer coefficient increases with a decrease in the gap of the duct. Besides, raising the imposed heat flux can cause a significant increase in the boiling heat transfer coefficients. However, the effects of the refrigerant mass flux and saturated temperature on the boiling heat transfer coefficient are milder. The results from the flow visualization show that the mean diameter of the bubbles departing from the heating surface decreases slightly at increasing R-134a mass flux. Moreover, the bubble departure frequency increases at reducing duct size mainly due to the rising shear stress of the liquid flow, and at a high imposed heat flux many bubbles generated from the cavities in the heating surface tend to merge together to form big bubbles. Correlation for the present saturated flow boiling heat transfer data of R-134a in the narrow annular duct is proposed. Additionally, data for some quantitative bubble characteristics such as the mean bubble departure diameter and frequency and the active nucleation site density are also correlated.  相似文献   

20.
A simultaneous visualization and measurement study has been carried out to investigate subcooled flow boiling and microbubble emission boiling (MEB) phenomena of deionized water in a partially heated Pyrex glass microchannel, having a hydraulic diameter of 155 μm, which was integrated with a Platinum microheater. Effects of mass flux, inlet water subcooling and surface condition of the microheater on subcooled flow boiling in microchannels are investigated. It is found that MEB occurred at high inlet subcoolings and at high heat fluxes, where vapor bubbles collapsed into microbubbles after contacting with the surrounding highly subcooled liquid. In the fully-developed MEB regime where the entire microheater was covered by MEB, the mass flux, the inlet water subcooling and the heater surface condition have only small effects on the boiling curves. The occurrence of MEB in microchannel can remove a large amount of heat flux, as high as 14.41 MW/m2 at a mass flux of 883.8 kg/m2 s, with only a moderate rise in wall temperature. Therefore, MEB is a very promising method for cooling of microelectronic chips. Heat transfer in the fully-developed MEB in the microchannel is presented, which is compared with existing subcooled flow boiling heat transfer correlations for macrochannels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏