首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 349 毫秒
1.
太阳能光伏光热建筑一体化系统的研究   总被引:1,自引:0,他引:1  
太阳能光伏光热一体化不仅能够有效降低光伏组件的温度,提高光伏发电效率,而且能够产生热能,从而大大提高了太阳能的转换效率。对光伏光热建筑一体化(BIPV/T)系统的两种主要模式:水冷却型和空气冷却型系统的工作原理和系统模型进行了理论介绍,详细说明了两种系统中热产品在家庭中的应用。并对目前研究情况下两个系统中存在的问题提出了改进方案。与常规建筑相比,光伏光热建筑减少了墙体得热,改善了室内空调负荷状况,提高了建筑节能效果。  相似文献   

2.
《Applied Thermal Engineering》2007,27(8-9):1259-1270
Hybrid photovoltaic/thermal (PV/T) systems consist of PV modules and heat extraction units mounted together. These systems can simultaneously provide electrical and thermal energy, thus achieving a higher energy conversion rate of the absorbed solar radiation than plain photovoltaics. Industries show high demand of energy for both heat and electricity and the hybrid PV/T systems could be used in order to meet this requirement. In this paper the application aspects in the industry of PV/T systems with water heat extraction is presented. The systems are analyzed with TRNSYS program for three locations Nicosia, Athens and Madison that are located at different latitudes. The system comprises 300 m2 of hybrid PV/T collectors producing both electricity and thermal energy and a 10 m3 water storage tank. The work includes the study of an industrial process heat system operated at two load supply temperatures of 60 °C and 80 °C. The results show that the electrical production of the system, employing polycrystalline solar cells, is more than the amorphous ones but the solar thermal contribution is slightly lower. A non-hybrid PV system produces about 25% more electrical energy but the present system covers also, depending on the location, a large percentage of the thermal energy requirement of the industry considered. The economic viability of the systems is proven, as positive life cycle savings are obtained in the case of hybrid systems and the savings are increased for higher load temperature applications. Additionally, although amorphous silicon panels are much less efficient than the polycrystalline ones, better economic figures are obtained due to their lower initial cost, i.e., they have better cost/benefit ratio.  相似文献   

3.
Y. Tripanagnostopoulos   《Solar Energy》2007,81(9):1117-1131
Hybrid photovoltaic/thermal (PV/T or PVT) solar systems consist of PV modules coupled to water or air heat extraction devices, which convert the absorbed solar radiation into electricity and heat. At the University of Patras, an extended research on PV/T systems has been performed aiming at the study of several modifications for system performance improvement. In this paper a new type of PV/T collector with dual heat extraction operation, either with water or with air circulation is presented. This system is simple and suitable for building integration, providing hot water or air depending on the season and the thermal needs of the building. Experiments with dual type PV/T models of alternative arrangement of the water and the air heat exchanging elements were performed. The most effective design was further studied, applying to it low cost modifications for the air heat extraction improvement. These modifications include a thin metallic sheet placed in the middle of the air channel, the mounting of fins on the opposite wall to PV rear surface of the air channel and the placement of the sheet combined with small ribs on the opposite air channel wall. The modified dual PV/T collectors were combined with booster diffuse reflectors, achieving a significant increase in system thermal and electrical energy output. The improved PV/T systems have aesthetic and energy advantages and could be used instead of separate installation of plain PV modules and thermal collectors, mainly if the available building surface is limited and the thermal needs are associated with low temperature water or air heating.  相似文献   

4.
设计并搭建了CPC低倍聚光太阳能PV/T单通道空气系统实验台,对不同工作环境下聚光PV/T系统的热电性能进行了实验研究。实验研究结果显示:在聚光条件下,系统的各表面温度随光照强度的增加而升高,随下部通道入口空气流速的增加而降低。聚光PV/T系统的最大输出功率可达到60W,比对应相同电池面积平板系统最大输出功率高20W。聚光PV/T系统的各效率随光照强度增加而增大,系统的最大电效率为11%,最大热效率为70%,最大火用效率为16%,比单纯发电时最大火用效率提高约5%。实验获得了一批新的有价值的实验数据,为聚光太阳能光伏光热系统的进一步研究提供了依据。  相似文献   

5.
在太阳能光伏热系统中,光伏电池温度过高会导致太阳能发电效率下降。相变微胶囊悬浮液(MEPCMS)是一种潜热型功能性流体,将其作为冷却介质用于太阳能光伏热系统可以有效降低光伏电池温度,提高系统的能量利用率。针对相变微胶囊易泄露、导热性差等问题提出了改性方法,使其具有光热转换功能并提升了综合性能。基于性能评价指标分析了太阳能光伏热系统性能的影响因素。结果发现,流速、浓度和太阳辐照量是影响MEPCMS在太阳能光伏热系统中换热性能的关键因素。适当增加MEPCMS浓度和流速能提高工质的换热性能,在降低光伏板温度的同时增加太阳辐照量和系统热电产量,但需结合太阳辐照量大小合理匹配工质的浓度和流速。未来研究方向可集中在提升MEPCMS在太阳能光伏热系统中的换热性能、探究运行参数和太阳辐照量之间的匹配关系、优化集热器结构、利用其蓄热性解决太阳能间歇性等方面。  相似文献   

6.
文章利用TRNSYS动态模拟软件研究了在我国不同建筑气候带条件下,不同类型的太阳能PV/T集热系统和普通太阳能PT集热系统的各项性能。其中,太阳能PV/T集热系统分为基于普通玻璃型太阳能PV/T集热系统和基于Low-e型太阳能PV/T集热系统。文章探究了基于普通玻璃型太阳能PV/T集热系统和基于Low-e型太阳能PV/T集热系统的电、热性能,分析了这两种太阳能PV/T集热器的光电转化效率,以及这两种太阳能PV/T集热系统和普通太阳能PT集热系统的光热转化效率、太阳能贡献率、一次能源节约率、供热节能率和环境效益等参数。分析结果表明:普通太阳能PT集热系统的吸热量、太阳能贡献率、供热节能率和CO2减排量均高于太阳能PV/T集热系统;与基于普通玻璃型太阳能PV/T集热系统相比,基于Low-e型太阳能PV/T集热系统的发电量降低了3.77%,但热效率、太阳能贡献率、一次能源节约率、供热节能率和环境友好度均较高。  相似文献   

7.
通过在光伏组件的背面连接了一个热电转换模块,形成一个光伏一热电混合模块,从而将光伏组件工作过程中产生的废热转换成电能的同时又降低了光伏组件的温度,进而提高了光电转换效率。将光伏一热电模块与百叶有效结合,从而实现了室内采光、通风及节约空间等多种功能。同时,为了提高光伏组件的入射太阳辐射,引入了可调节的抛物型双面聚焦板,减少了太阳能电池板的面积,从而减少了太阳能发电的成本。  相似文献   

8.
为解决太阳电池的发电效率随温度升高而下降以及地源热泵系统供热引起的土壤热失衡问题,以典型居住建筑的光伏/光热-地源热泵(PV/T-GSHP)联合供热系统为研究对象,基于TRNSYS软件,采用土壤温度、地源热泵机组季节能效比、光伏发电效率和太阳能保证率为评价指标,对该联合供热系统进行运行性能分析。研究结果表明:夏热冬冷地区(以长沙为例)太阳能保证率相对较高,PV/T组件面积为满屋顶最大化安装(900 m2)时,第20年末土壤温度相比初始地温仅升高0.8 ℃,热泵机组季节能效比约为5.1,太阳能保证率为97.0%~98.7%;不同气候地区的太阳能保证率与PV/T组件面积和建筑全年累计供热量有关,通过定义单位建筑全年累计供热量PV/T组件面积指标,得到中国不同气候地区的太阳能保证率与该指标的耦合关系,回归方程的决定系数R2为0.983,得出在已知建筑全年累计供热量和太阳保证率设计目标值的条件下所需PV/T组件面积的计算方法。PV/T-GSHP联合供热系统的全年运行能耗显著小于平板太阳能集热器-地源热泵联合系统(最小降幅为沈阳,49.7%),远小于空气源热泵(最小降幅为石家庄,79.8%)和燃气壁挂炉(最小降幅为沈阳,65.1%)。  相似文献   

9.
Solar photovoltaic-thermal (PV/T) collectors, are hybrid collectors used to convert solar radiation into usable thermal and electrical energy. Recently, the field of research on PV/T is has focused on improving the efficiency of the PV/T collector by replacing the conventional heat transfer fluids (HTFs) with nanofluids. This article investigates the effect of hybrid nanofluids mixture ratio on the useful energy and overall efficiency of a PV/T collector operating with Al2O3-ZnO water nanofluid as the HTF. Experiments to measure the thermophysical properties of the hybrid nanofluids were conducted for various temperatures, volume concentrations, and mixture ratios, furthermore, accurate correlation models were proposed. Metrological data and energy output readings collected from the PV solar farm at Cyprus International University were used to validate our model. The study observed that at the optimum mixture ratio (0.47 of Al2O3 in the hybrid), the electrical, thermal, and exergy efficiencies of the PV/T collector are 13.8%, 55.9%, and 15.13% respectively. Also, the cell temperature drops by 21% when the mass flow rate is 0.1 kg/s as compared to when it is 0.01 kg/s. Finally, the study concludes that by using the Al2O3-ZnO hybrid nanofluid an overall peak thermal efficiency of 91% can be attained, and this represents a 34% enhancement in the collector's performance when compared to water.  相似文献   

10.
为充分利用建筑屋顶,解决光伏光热一体化(PV/T)集热器光电转换效率的高温减益问题,并提高太阳能综合利用率和集热品位,文章构建了一种基于太阳光谱分频利用技术的光伏/光热模块分离式的小型聚光式PV/T集热器。通过建立其光/电/热理论分析模型及TracePro/Fluent数值仿真模型,以南京地区气象数据为例,综合分析其光/电/热性能,结果表明:该集热器以与安装地纬度等值的倾角南北轴向放置时,其年均光学效率为64.97%,工质出口温度为90℃时的系统光电/光热效率分别为12.47%,40.09%,系统综合热效率达72.91%,且其结构简单、外形轻薄,有望实现与普通建筑的有效结合。  相似文献   

11.
Hybrid conversion of solar radiation implies simultaneous solar radiation conversion into thermal and electrical energy in the PV/Thermal collector. In order to get more thermal and electrical energy, flat solar radiation reflectors have been mounted on PV/T collector. To obtain higher solar radiation intensity on PV/T collector, position of reflectors has been changed and optimal position of reflectors has been determined by both experimental measurements and numerical calculation so as to obtain maximal concentration of solar radiation intensity. The calculated values have been found to be in good agreement with the measured ones, both yielding the optimal position of the flat reflector to be the lowest (5°) in December and the highest (38°) in June. In this paper, the thermal and electrical efficiency of PV/T collector without reflectors and with reflectors in optimal position have been calculated. Using these results, the total efficiency and energy-saving efficiency of PV/T collector have been determined. Energy-saving efficiency for PV/T collector without reflectors is 60.1%, which is above the conventional solar thermal collector, whereas the energy-saving efficiency for PV/T collector with reflectors in optimal position is 46.7%, which is almost equal to the values for conventional solar thermal collector. Though the energy-saving efficiency of PV/T collector decreases slightly with the solar radiation intensity concentration factor, i.e. the thermal and electrical efficiency of PV/T collector with reflectors are lower than those of PV/T collector without reflectors, the total thermal and electrical energy generated by PV/T collector with reflectors in optimal position are significantly higher than total thermal and electrical energy generated by PV/T collector without reflectors.  相似文献   

12.
The thermoelectric (TE) solar air collector, sometimes known as the hybrid solar collector, generates both thermal and electrical energies simultaneously. A double-pass TE solar air collector has been developed and tested. The TE solar collector was composed of transparent glass, air gap, an absorber plate, thermoelectric modules and rectangular fin heat sink. The incident solar radiation heats up the absorber plate so that a temperature difference is created between the thermoelectric modules that generates a direct current. Only a small part of the absorbed solar radiation is converted to electricity, while the rest increases the temperature of the absorber plate. The ambient air flows through the heat sink located in the lower channel to gain heat. The heated air then flows to the upper channel where it receives additional heating from the absorber plate. Improvements to the thermal and overall efficiencies of the system can be achieved by the use of the double-pass collector system and TE technology. Results show that the thermal efficiency increases as the air flow rate increases. Meanwhile, the electrical power output and the conversion efficiency depend on the temperature difference between the hot and cold side of the TE modules. At a temperature difference of 22.8 °C, the unit achieved a power output of 2.13 W and the conversion efficiency of 6.17%. Therefore, the proposed TE solar collector concept is anticipated to contribute to wider applications of the TE hybrid systems due to the increased overall efficiency.  相似文献   

13.
The temperature increase due to incident solar radiation has an adverse impact on the electrical output of photovoltaic (PV) modules. A theoretical model of the fabricated and tested bionic evaporation backside cooling was established and verified by experimental investigation. A microfluidic structure featuring micropores consists of two polymer layers attached on the backside of a PV cell model. The thermal performance of roof-mounted PV modules with rear panel air ventilation was mathematically described and extended by the cooling capabilities of the developed bionic evaporation foil. The results of experimental investigations performed in a roof equivalent test environment consisting of a wind tunnel within a climate chamber are in good accordance to the established model. Experimentally, temperature reductions at low incident solar power of less than 575 W causing an efficiency gain for up to 4.8% have been demonstrated while the model implicates an efficiency increase of 10% for real roof systems at an incident solar radiation of 1000 W.  相似文献   

14.
A polymer solar heat collector was combined with single-crystal silicon PV cells in a hybrid energy-generating unit that simultaneously produced low temperature heat and electricity. The PV/T unit was tested experimentally to determine its thermal and photovoltaic performance, in addition to the interaction mechanisms between the PV and thermal energy systems. Thermal efficiency measurements for different collector configurations are compared, and PV performance and temperature readings are presented and discussed. An analytical model for the PV/T system simulated the temperature development and the performance of both the thermal and photovoltaic units.  相似文献   

15.
In this paper, an attempt is made to investigate the thermal and electrical performance of a solar photovoltaic thermal (PV/T) air collector. A detailed thermal and electrical model is developed to calculate the thermal and electrical parameters of a typical PV/T air collector. The thermal and electrical parameters of a PV/T air collector include solar cell temperature, back surface temperature, outlet air temperature, open-circuit voltage, short-circuit current, maximum power point voltage, maximum power point current, etc. Some corrections are done on heat loss coefficients in order to improve the thermal model of a PV/T air collector. A better electrical model is used to increase the calculations precision of PV/T air collector electrical parameters. Unlike the conventional electrical models used in the previous literature, the electrical model presented in this paper can estimate the electrical parameters of a PV/T air collector such as open-circuit voltage, short-circuit current, maximum power point voltage, and maximum power point current. Further, an analytical expression for the overall energy efficiency of a PV/T air collector is derived in terms of thermal, electrical, design and climatic parameters. A computer simulation program is developed in order to calculate the thermal and electrical parameters of a PV/T air collector. The results of numerical simulation are in good agreement with the experimental measurements noted in the previous literature. Finally, parametric studies have been carried out. Since some corrections have been down on thermal and electrical models, it is observed that the thermal and electrical simulation results obtained in this paper is more precise than the one given by the previous literature. It is also found that the thermal efficiency, electrical efficiency and overall energy efficiency of PV/T air collector is about 17.18%, 10.01% and 45%, respectively, for a sample climatic, operating and design parameters.  相似文献   

16.
G. Fraisse  C. Mnzo  K. Johannes 《Solar Energy》2007,81(11):1426-1438
The integration of photovoltaic (PV) modules in buildings allows one to consider a multifunctional frame and then to reduce the cost by substitution of components. In order to limit the rise of the cell operating temperature, a photovoltaics/thermal (PV/T) collector combines a solar water heating collector and PV cells. The recovered heat energy can be used for heating systems and domestic hot water. A combination with a Direct Solar Floor is studied. Its low operating temperature level is appropriate for the operating conditions of the mono- or poly-crystalline photovoltaic modules which are selected in that study. However, for a system including a glass covered collector and localised in Mâcon area in France, we show that the annual photovoltaic cell efficiency is 6.8% which represents a decrease of 28% in comparison with a conventional non-integrated PV module of 9.4% annual efficiency. This is obviously due to a temperature increase related to the cover. On the other hand, we show that without a glass cover, the efficiency is 10% which is 6% better than a standard module due to the cooling effect.Moreover, in the case of a glazed PV/T collector with a conventional control system for Direct Solar Floor, the maximum temperature reached at the level of the PV modules is higher than 100 °C. This is due to the oversize of the collectors during the summer when the heating needs are null, i.e. without a heated swimming pool for example. This temperature level does not allow the use of EVA resin (ethylene vinyl acetate) in PV modules due to strong risks of degradation. The current solution consists of using amorphous cells or, if we do not enhance the thermal production, uncovered PV/T collector. Further research led to water hybrid PV/T solar collectors as a one-piece component, both reliable and efficient, and including the thermal absorber, the heat exchanger and the photovoltaic functions.  相似文献   

17.
The present work developed a spectral splitting hybrid photovoltaic/thermal (PV/T) system based on polypyrrole nanofluid. This hybrid PV/T system can overcome the limitation of temperature in traditional PV/T, and achieve a high-temperature thermal output. In this system, the polypyrrole nanofluid employed in the spectral splitting filter can absorb the solar radiation that can't be efficiently utilized by PV cell unit, and convert it into medium-temperature thermal energy. The principle and methodology of the experimental system design was discussed, and the effect of particle concentration on the performance of system was investigated as well. The present work not only verifies the application potential of polypyrrole nanofluid in spectral splitting PV/T system, but also obtains some important rules on the performance. The results indicate that the temperature of nanofluid and the PV efficiency of cell unit itself increases with the particle concentration, but the thermal efficiency decreases simultaneously. The maximum overall efficiency of this hybrid PV/T system with polypyrrole nanofluid filter was 25.2%, which was 13.3% higher than that without filter. More importantly, the medium-temperature thermal energy can be harvested in such a hybrid system. Furthermore, an optimal particle concentration can probably realize a higher overall efficiency.  相似文献   

18.
In a photovoltaic/thermal (PV/T) collector, a portion of absorbed solar energy is transformed into electrical energy, and the remaining part is transformed into thermal energy. Increasing waste heat collection and energy conversion rates are important to improve the performance of the PV/T collector. The utilization of microencapsulated phase change slurry (MPCS) in a PV/T collector to cool photovoltaic modules is an effective way, and electrical and thermal performances of the collector are improved. To investigate influences of operating parameters on performances of PV/T collector, numerical simulation is put into effect to analyze influences of the mass fraction of MPCS on the collector performance. The influences of MPCS mass flow rate and collector channel height on collector performances are also studied. When the flow rate is 0.005 kg/s and the channel height is 0.010 m, the PV/T collector obtains the best net efficiency with a MPCS mass concentration of 20 wt%. But electrical efficiency difference between 15 and 20 wt% is not obvious. With the growth in mass fraction, PV temperature drops more and more slowly because outlet fluid has not fully melt. Take PV/T collector performances into consideration, 15 wt% MPCS is a better choice to cool photovoltaic modules.  相似文献   

19.
20.
Photovoltaic-thermal collectors (or PV-T collector) are hybrid collectors where PV modules are integrated as an absorber of a thermal collector in order to convert solar energy into electricity and usable heat at the same time. In most of the cases, the hybrid collectors are made by the superposition of a PV module on the thermal absorber of a solar collector. In this paper, the approach is different and is to analyze thermal and optical properties related to both PV and solar thermal functions in order to identify an optimum combination leading to a maximum overall efficiency. Indeed, although these two functions do not exploit the same range of radiation wavelengths, thermal and PV functions are not so complementary due to photo-conversion thermal dependency. In this context, an alternative PV cell lamination has been developed with increased optical and thermal performance. The improvements were evaluated around 2 mA/cm2 in terms of current density in comparison to a standard module encapsulation. Based on this technique, a real size PV-T module has been built and tested at Fraunhofer solar test facilities. The results show a global efficiency of the PV-T collector above 87% (79% thermal efficiency plus 8.7% electrical efficiency, based on the absorber area).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号