首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 156 毫秒
1.
UBF-BAF组合工艺处理焦化废水   总被引:2,自引:0,他引:2  
采用UBF—BAF组合工艺处理焦化废水,考察了处理效果。结果表明,经UBF处理后,废水的可生化性得以提高;HRT及进水负荷对NH3-N去除效果的影响明显大于对COD的,BAF反应器内填料的前段主要用于去除COD,后段主要用于去除NH3-N;当厌氧段HRT为15.4h、好氧段HRT为31.3h时,系统对COD和NH3-N的去除效果均较好。稳态运行时,系统对COD、NH3-N、TN、TOC和挥发酚的去除率分别为81.5%、96.4%、56.9%、81.8%和99.9%。  相似文献   

2.
通过中试研究了三级BAF工艺(C+N+DN)处理低C/N值生活污水的脱氮效能,考察了硝化液回流比的影响.结果表明:在C柱和N柱的气水比分别为3:1和2:1,C柱、N柱和DN柱的HRT分别为1.25、1.25和0.84 h,以及水温为25~32℃的条件下,增加硝化液回流比可以明显提高系统对NH+4-N和TN的去除效果,但对去除COD无明显影响.当回流比为0.25%、50%和100%时,系统对NH+4-N的去除率分别为84%、88%、97%和98%,对TN的去除率分别为68%、84%、89%和90%,但对COD的去除率均约为87%.考虑到经济性,建议选择回流比为50%,此时系统出水NH+4-N、TN和COD浓度均达到了国家一级A排放标准.  相似文献   

3.
A/HMBR组合工艺处理生活垃圾中转站废水   总被引:1,自引:0,他引:1  
采用厌氧-复合式膜生物反应器(A/HMBR)组合工艺处理模拟生活垃圾中转站废水,考察了水力停留时间和回流比对COD、NH3-N、TN去除效果的影响。结果表明,在水力停留时间为42h、回流比为3时,系统对COD、NH3-N、TN的去除率最高,分别为95%、89%、78%。复合式膜生物反应器中膜污染的主要原因为溶解性有机物对膜孔的堵塞。  相似文献   

4.
为了提高曝气生物滤池(BAF)对景观水体的脱氮效果,开发了前置反硝化BAF工艺,考察了其对景观水体的处理效果及影响因素,并与传统BAF工艺作比较。结果表明,前置反硝化BAF工艺对TN和浊度的去除效果明显优于传统BAF工艺,前者对TN和浊度的平均去除率分别为45%和88%,而后者的分别为30%和47%;两种工艺对COD和氨氮的去除效果相近,但前置反硝化BAF工艺的出水水质更稳定;对于前置反硝化BAF工艺,当水力负荷为1.42~4.95 m/h时,对COD、氨氮和TN的去除率均随水力负荷的增加而降低;在水力负荷为2.12 m/h的条件下,回流比对COD和氨氮的去除效果影响不大,但对TN的去除率随回流比的增加呈先升高后降低的趋势,最佳回流比为1.5∶1;另外,对TN的去除率随进水C/N值的增加而升高,当C/N6时,系统的脱氮效果较好。  相似文献   

5.
一体式A/O—MBR工艺处理生活污水试验研究   总被引:1,自引:0,他引:1  
采用一体式A/O—MBR工艺处理生活污水。试验结果表明,该工艺对污染物的去除效果良好,对COD、NH3-N、TN、TP的平均去除率分别为97.1%、97.58%、73%、66.48%;微生物对COD和NH3-N的降解起主导作用,膜截留对COD有一定的去除作用,但对NH3-N的去除作用不太明显;A/O—MBR工艺对TN、TP的去除效果要比传统MBR好,且膜区较低的污泥浓度大大降低了膜污染速度。  相似文献   

6.
两级曝气生物滤池对垃圾渗滤液的脱氮效果   总被引:2,自引:0,他引:2  
经过生化工艺处理后的垃圾渗滤液,其总氮含量仍然很高,往往难以达标排放.采用中试规模的两级曝气生物滤池(BAF)对垃圾渗滤液进行深度处理,研究了滤层与其工作性能的关系.结果表明,两级BAF工艺对COD的去除率稳定在80%以上,出水NH3-N可以保持在3ms/L以下.当HRT为8 h左右、进水温度为20~26℃、气水比为5:1、BAF2出水以回流比为1:1回流至BAF1时,由下至上的各区间段对COD和NH3-N的去除率与滤层高度呈正相关.中部进气使得两级BAF工艺对COD和NH3-N的去除主要集中在下部和中部区域,上部对COD和氨氮的去除作用微弱.  相似文献   

7.
将Carrousel氧化沟工艺与生物膜工艺相结合而形成新型复合式Carrousel氧化沟。研究了主沟道底部曝气量、隔板填料区出水量、污泥回流比对COD、NH+4-N、TN去除效果的影响,以期获得较佳的运行参数。结果表明,在进水量为136 m3/d、水力停留时间为7.1 h、主沟底部曝气量为22 m3/h、隔板区底部曝气量为16 m3/h、隔板区出水量为4 m3/h、污泥回流比为100%的条件下,出水COD、NH+4-N、TN浓度均能达到一级A标准,去除率分别为87.4%、95.7%、61.7%,具有较好的去除污染物效果。  相似文献   

8.
改进型BIOSTYR处理景观水研究   总被引:1,自引:0,他引:1  
采用改进型BIOSTYR工艺处理景观水,考察了对TN、NH4^+-N、COD、浊度的去除效果。结果表明,该工艺除污效果好,对COD的平均去除率为55.40%,对NH4^+-N的平均去除率〉90%,对TN的平均去除率为52.08%,出水浊度为1.2~1.5NTU。  相似文献   

9.
接触氧化/BAF工艺处理城市生活污水的挂膜研究   总被引:4,自引:0,他引:4  
为了实现污水的就地处理与回用,开发了接触氧化/BAF工艺,并对该工艺的挂膜启动进行了研究,分析了其挂膜过程中生物相的变化情况及对COD、NH4^+-N的去除效果。结果表明,该工艺对COD的去除主要集中在接触氧化段,对NH4^+-N的去除主要集中在BAF段;当接触氧化段对COD的去除率稳定在80%左右、BAF段对NH4^+-N的去除率稳定在90%以上,且填料中的生物相趋于稳定时,标志着系统挂膜成功,历时约27d。此时,系统出水COD和NH4^+-N的浓度分别稳定在50、0.2mg/L左右。  相似文献   

10.
采用曝气生物滤池(BAF)与好氧膜生物反应器(MBR)联用工艺处理城镇污水,并在膜生物反应器内投加硫酸亚铁进行化学除磷。结果表明,系统出水的COD、NH+4-N、TN、TP平均值分别为8、0.3、7.5、0.2 mg/L,优于《城镇污水处理厂污染物排放标准》(GB 18918—2002)的一级A标准。在回流比为200%时曝气生物滤池的处理效果最好,BAF对NH+4-N、TN的平均去除率分别为86%、64%;在MBR中投加硫酸亚铁进行同步化学除磷,与静态化学除磷相比平均减少投药量达66.7%,且对膜污染不会造成显著影响。  相似文献   

11.
Lackner S  Terada A  Smets BF 《Water research》2008,42(4-5):1102-1112
A 1-d multi-population biofilm model was constructed to study the effect of heterotrophic activity on completely autotrophic ammonium (NH4+) removal in membrane-aerated (counter-diffusion) versus conventional biofilm systems (co-diffusion). Growth of heterotrophic bacteria (HB) was supported either solely by biomass decay products or by organic carbon (as chemical oxygen demand (COD)) in the influent. Three scenarios were considered: influence of HB growing on biomass decay products on steady-state performance (total nitrogen (TN) removal efficiency); influence of the influent COD/N ratio on steady-state performance (supplying COD in the influent); and impact of dynamic changes in the influent COD/N ratio on TN removal efficiency. The results revealed that the TN removal efficiency in the counter-diffusion biofilm was significantly different when HB were included in the simulations at NH4+ surface loads of LNH4>2.7 g - N m(-2) d(-1). Influent COD significantly altered the microbial community composition in the counter-diffusion biofilm and anaerobic NH4+ oxidation could not be sustained at COD/N>2. The co-diffusion system, however, was less affected and more than 50% of the TN removal originated from anaerobic NH4+ oxidation at those ratios. Perturbation experiments showed that step increases to influent COD/N ratios of 2 or higher over a period of 50 d or longer caused a loss of anaerobic NH4+ oxidation capacity which could not be regained within a reasonable time frame (>1000 d) in the counter-diffusion system. In contrast, simulating a 1-d sloughing event only caused a disturbance of 200 d although a maximum biofilm loss of 90-95% occurred. These results clearly indicate the importance of heterotrophic activity in autotrophic N removal biofilms, especially in counter-diffusion systems where they may compromise N removal capacity.  相似文献   

12.
陶涛 《重庆建筑》2011,(10):48-51
在好氧生物滤池水力负荷为3.0m^3/(m^2·h),温度为20-25℃,缺氧柱投加碳源量为60mg/L,将气水比分别控制为1:1、2:1、3:1、4:1,以污水厂二级出水为进水水源,考察了气水比对多级曝气生物滤池系统去除CODCr、氨氮、TN等效果的影响。结果表明:气水比对一级好氧生物滤池系统处理效能影响显著。当气水比从1:1提高到3:1时,一级好氧生物滤池对CODCr、氨氮的去除率明显提高,分别从22.26%提高至34.46%和35.06%提高至63.98%;对TN的去除率明显降低,从8.6%降低至4.8%;当气水比继续增大到4:1时,CODCr、氨氮及TN的去除率基本保持稳定,分别为36.66%、68.66%和4.7%。  相似文献   

13.
采用UCT工艺处理低C/N值城市污水,考察了其处理效果及影响因素。结果表明:UCT工艺对COD的平均去除率为87.3%,进水中较高浓度的氨氮对COD去除效果有一定的影响;系统运行稳定后,对氨氮的去除率可保持在90%以上,硝化效果较好;在无外加碳源的情况下,UCT工艺对总氮的去除率为50%左右,投加甲醇碳源调节污水的C/N值为6.2左右时,对总氮的去除率可稳定在80%以上;进水中较高浓度的氨氮对系统除磷效果的影响较大,在硝化效果不好的情况下对总磷的去除率可达86%,在硝化效果较好的情况下除磷效率较低,为50%左右。  相似文献   

14.
采用非织造布动态膜生物反应器处理模拟城市生活污水,结果表明,非织造布的三维空间立体结构有利于动态膜的快速形成,反应器稳定运行期间,系统对SS的去除效果良好,大部分情况下未在出水中检出SS;系统对COD、NH3-N、TN、TP的平均去除率分别为90.1%、89%、37.9%和2.9%;非织造布动态膜在污水处理中起到了泥水分离、提高MLSS的作用,其对COD有一定的去除作用,对NH3-N、TN等则基本无去除作用,混合液中的微生物起到了主要的除污作用。  相似文献   

15.
气水比对高分子填料BAF脱氮效能的影响   总被引:1,自引:1,他引:0  
采用高分子载体作为生物填料,以模拟生活污水为处理对象,对两级曝气生物滤池(BAF)的脱氮效能进行了试验研究,着重考察了气水比对BAF去除COD、NH3-N和TN的影响,并探讨了系统内氮素的转化规律和提高脱氮效能的途径。结果表明,当平均水温为22~32℃、进水流量为4 L/h、进水COD为150 mg/L左右、进水NH3-N为60 mg/L左右、一级BAF的气水比为4∶1、二级BAF的气水比为2∶1时,系统的处理效果最佳,对COD、NH3-N和TN的总平均去除率分别达到84.33%、87.84%和56.06%。系统通过同时短程硝化反硝化实现了低能耗、高效率的脱氮。  相似文献   

16.
采用“EGSB-生物接触氧化-BAF”联合工艺处理葡萄糖生产废水,着重研究了pH值和容积负荷对EGSB反应器去除效果的影响。结果表明,以厌氧颗粒污泥作为EGSB的接种污泥,30d左右便可完成启动,且能形成灰黑色和黑色颗粒污泥;采用出水回流和人为投加碱性物质可以增强系统的缓冲能力,有效缓解系统酸碱平衡失调。当进水COD为3000~4000mg/L、SS为800~1000mg,/L、NH3-N为15~20mg/L时,采用该联合工艺处理后,对COD、SS和NH3-N的平均去除率分别达98%、92%和78%,处理效果好而且稳定。  相似文献   

17.
一体化IMBR处理低碳城市污水的脱氮研究   总被引:1,自引:0,他引:1  
在进水C/N为3、4、5和HRT为4、8、12h的条件下,研究了一体化间歇曝气膜生物反应器(IMBR)对COD、NH4^+-N、TN的去除效果。研究表明,在低C/N条件下,IMBR仍有很好的脱氮效果,出水COD、TN、NH4^+-N达到了GB18918--2002标准的一级A标准;随着C/N的增加则对各污染物的去除率都有所升高;随着HRT的延长,IMBR对COD、TN、NH4^+-N的去除率有较大的提高,但当HRT〉8h后,随着HRT的延长,对COD的去除率反而略有下降。  相似文献   

18.
韩佳  岳秀萍 《山西建筑》2012,38(17):140-142
结合太原市经济技术开发区污水处理厂工艺性能试验,重点考察了一体式A/O复合反应池的环境温度、C/N比和硝化液回流比对一体式A/O复合反应池脱氮效果的影响,结果表明:在20℃~35℃时,NH3-N的去除率在70%~80%;当C/N值为3时,NH3-N去除率为79%左右,平均出水TN为12.1 mg/L;当回流比为200%时,NH3-N去除率为98.6%,TN去除率为75.5%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号