首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 25 毫秒
1.
The utilisation of waste materials in the construction industry is an effective way to sanitise the environment and reduces the cost of construction. In this research, palm oil clinker (POC) aggregates was used to fully replace normal aggregates to produce structural lightweight concrete. This concrete was used in the construction of composite slabs with profiled steel sheet. A total of eight full scale composite slabs, six palm oil clinker concrete (POCC) slabs and two conventional concrete slabs were constructed and tested in accordance to Eurocode 4: Part 1.1 and BS 5950: Part 4: 1994. Two shear spans were used, 450 mm for short shear span and 900 mm for long shear span. The structural behaviour of the slabs was investigated and compared. The horizontal shear-bond strength between the concrete and the steel was determined according to two methods; mk and partial shear connection methods. Test results show that the structural behaviour and the horizontal shear-bond strength of the POCC slabs are nearly similar to the conventional concrete slabs. The mechanical interlock (m) and the friction (k) between the steel and the concrete are 117.67 N/mm2 and 0.0973 N/mm2, respectively and the design horizontal shear-bond strength using m-k and PSC methods is 0.248 N/mm2 and 0.215 N/mm2, respectively. The difference between the two methods is 13.3%. POCC is therefore suitable to be used for structural applications with a reduction in weight of 18.3% compared to conventional concrete composite slabs.  相似文献   

2.
This paper presents an experimental study investigating the behavior of FRP-reinforced concrete bridge deck slabs under concentrated loads. A total of eight full-scale deck slabs measuring 3000-mm long by 2500-mm wide were constructed. The test parameters were: (i) slab thickness (200, 175 and 150 mm); (ii) concrete compressive strength (35–65 MPa); (iii) bottom transverse reinforcement ratio (1.2–0.35%); and (iv) type of reinforcement (GFRP, CFRP, and steel). The slabs were supported on two parallel steel girders and were tested up to failure under monotonic single concentrated load acting on the center of each slab over a contact area of 600 × 250 mm to simulate the footprint of sustained truck wheel load (87.5 kN CL-625 truck). All deck slabs failed in punching shear. The punching capacity of the tested deck slabs ranged from 1.74 to 3.52 times the factored load (Pf) specified by the Canadian Highway Bridge Design Code (CHBDC) CAN/CSA S6-06. Besides, the ACI 440.1R-06 punching strength equation greatly underestimated the capacity of the tested slabs with an average experimental-to-predicted punching capacity ratio (Vexp/Vpred) of 3.17.  相似文献   

3.
This paper presents experimental investigations on the thermal and mechanical behavior of composite floors subjected to ISO standard fire. Four 5.2 m×3.7 m composite slabs are tested with different combinations of the presence of one unprotected secondary beam, direction of ribs, and location of the reinforcement. The experimental results show that the highest temperature in the reinforcements occurs during the cooling phase (30–50 °C increment after 10-min cooling). The temperature at the unexposed side of the slabs is below 100 °C up to 100-min heating, compared to the predicted fire resistance close to 90 mins from EC4. For the slabs without secondary beams, the cracks first occur around the boundaries of the slab, while for the slabs supported by one unprotected secondary beam, concrete cracks first occur on the top of the slab above the beam due to the negative bending moment, and later on develop around boundaries. Debonding is observed between the steel deck and concrete slab. The secondary beam significantly impacts the deformation shape of tested slabs. Although a large deflection, 1/20 of the span length, is reached in the tests, the composite slabs can still provide sufficient load-bearing capacity due to membrane action. The occurrence of tensile membrane action is confirmed by the measured tensile stress in the reinforcement and compressive stress in the concrete. A comparison between measured and predicted fire resistance of the slabs indicates that EC4 calculations might be used for the composite slabs beyond the specified geometry limit, and the prediction is conservative.  相似文献   

4.
Rehabilitation and strengthening of concrete structures with externally bonded fibre reinforced polymers (FRPs) has been a viable technique for at least a decade. An interesting and useful application is strengthening of slabs or walls where openings are introduced. In these situations, FRP sheets are very suitable; not only because of their strength, but also due to that they are easy to apply in comparison to traditional steel girders or other lintel systems. Even though many benefits have been shown by strengthening openings with FRPs not much research have been presented in the literature.In this paper, laboratory tests on 11 slabs with openings, loaded with a distributed load are presented together with analytical and numerical evaluations. Six slabs with openings have been strengthened with carbon fibre reinforced polymers (CFRPs) sheets. These slabs are compared with traditionally steel reinforced slabs, both with (four slabs) and without openings (one slab). The slabs are quadratic with a side length of 2.6 m and a thickness of 100 mm. Two different sizes of openings are used, 0.85 × 0.85 m and 1.2 × 1.2 m.The results from the tests show that slabs with openings can be strengthened with externally bonded CFRP sheets. The performance is even better than for traditionally steel reinforced slabs. The numerical and analytical evaluations show good agreement with the experimental results.  相似文献   

5.
The paper aims at the determination of the possible limits of vapour resistance and liquid water permeability alteration in the case of the exterior painted thin-layer render finish of the building walls from outside insulated with the mineral wool slabs when exploited in the area of cold and humid climate that could guarantee a normal moisture state of the wall insulating system. The moisture testing of the insulating system’s fragments was carried out in the climatic chamber, where the climatic parameters were modelled on the basis of the climatic typical of Lithuania. Thin-layer render was coated with acrylic paints. When the thickness of the paint coating on thin-layer render was increased from 0.08 mm to 0.24 mm, the liquid water absorption coefficient decreased by 59% and vapour resistance increased by 43%. It has also been determined that in the double-layer system paint coating – thin-layer render condensation moisture will be accumulated when the thickness of the air layer sd equivalent to the material’s water vapour permeability is higher than 0.6 m. Rain will have an impact on the wall’s moisture state, when the liquid water absorption coefficient w of the double-layer system paint coating – thin-layer render is higher than 0.025 kg/(m2 h0.5). The micro-lens discovered in the areas of moisture accumulation by the thermographic analysis should be considered as the rudiments of the defect formation in the exterior insulating system.  相似文献   

6.
A parameter-based acoustic emission (AE) technique is applied to AE signals acquired in physical experiments carried out on a series of predamaged reinforced concrete slabs. Three reinforced concrete slabs without shear reinforcement with dimensions of 1.50 × 1.50 × 0.23 m are subjected to cycles of a concentrated centric load with increasing peak values up to failure. The slabs had been previously exposed to impact loads in rockfall experiments and exhibit an unknown damage condition yet to be determined. Acoustic emissions are recorded during the loading and unloading cycles and evaluated. An analysis of load ratio and calm ratio associated with the Kaiser effect is performed. Damage classification is carried out successfully. Definitions of load ratio and calm ratio are reconsidered and specified. A static preloading of the slabs is approximated. The relationship between cracking process, failure mechanism and the acoustic emissions that occur is described and discussed.  相似文献   

7.
This paper describes an experimental investigation on the flexural and anchorage strength of slate for cladding. The study has been conducted on sawed slate specimens, all showing the same surface finishing. Slate flexural strength was compared for two distinct situations: (i) using a 3-Point flexure loading configuration in batches of materials with larger cross-sectional specimen dimension (50 × 30 mm2); and (ii) using a 4-Point flexure loading configuration in the same batch of materials but with smaller cross-sectional dimensions (30 × 25 mm2). The 4-Point bending specimens were tested in three different directions considering slate anisotropy planes. Load was applied along the direction perpendicular to the planes of schistosity; and also along two directions parallel to the planes of schistosity. Slate anchorage strength has been determined on slate slabs with 400 × 200 × 30 mm3 with dowel anchorage in 8 mm diameter cylindrical holes with 35 mm depth. Test load was applied perpendicularly to the schistosity planes. Cladding stone in building facades and its supporting systems must be compatible with the behaviour and performance of other interfacing systems, such as curtain walls and superstructure frames. In this sense, a properly executed dimensional stone cladding should be designed and installed within the capabilities and limitations of the slate’s support system to resist all active forces or actions. The results of this work reveal the importance of complementary characterization techniques for dimension stone cladding, particularly for anisotropic rocks as slates. From the results it is possible to conclude that schistosity planes have an utter influence on either anchorage or flexural strength.  相似文献   

8.
The aim of this study is the design, fabrication and experimentally characterization of an optimized polymer concrete (PC). To this end, three factors, namely: the aggregate size, epoxy resin weight percentage, and chopped glass fiber percentage; are considered as the influencing factors on the compressive strength, bending strengths and interfacial shear strength between the PC and steel. The number of tests which are necessary to simultaneously optimize three above strengths of the PC are reduced based on the design of experiment using the orthogonal array technique or so-called Taguchi method. Comparison of the predicted strengths based on the Taguchi approach with the measured experimental results shows a good correlation between them. Afterward, the effect of three freeze/thaw thermal cycles; 25 °C to ?30 °C (cycle-A), 25 °C to 70 °C (cycle-B) and ?30 °C to 70 °C (cycle-C) for 7 days; on the strengths of the optimized PC is experimentally investigated. Comparison of the experimental results for the mechanical strengths measured at room temperature (RT) and above thermal cycles shows that the compressive strength of the optimally designed PC is not affected by heating and cooling cycles. On the other hand, the bending strength is more affected by exposing PC to the thermal cycle-B. The interfacial shear strength becomes affected by exposing the PC to cycles-A and -B, whereas no changes are observed on this strength by exposing to the thermal cycle-C. In general, among the three thermal cycles, cycle-B exerted the most deteriorating effect on the strengths.  相似文献   

9.
Both the RTFO (rolling-thin film oven) aging of asphalt binders and the STOA (short-term oven aging) of asphalt mixtures are designed to simulate aging during the construction of hot mix asphalt (HMA) pavements. Many studies have been conducted evaluating the aging effects on asphalt binders since their properties can be easily measured using many conventional tests, such as rotational viscometer, DSR (dynamic shear rheometer), and BBR (bending beam rheometer). However, studies on asphalt mixture aging have been limited to mechanical properties such as strength and fatigue characteristics because considerable effort is required to identify the aging of the asphalt binder in a mixture. This study evaluated the effects of short-term oven aging on asphalt mixtures using the GPC (gel-permeation chromatography) procedure. Nine asphalt mixtures, using three different binder sources, were prepared and five short-term aging methods were used to evaluate these mixes. For comparison, the RTFO aging was also conducted for nine asphalt binders. The aging of a binder within asphalt mixtures, including polymer-modified mixtures, could be identified under various short-term aging conditions. Statistical analysis of the GPC test results indicated that two commonly used short-term aging methods in the laboratory, a 154 °C oven aging for 2 h and a 135 °C oven aging for 4 h, are not significantly different, based on the increase in the large molecular size (LMS) ratios. The RTFO aging method was found to have less effect on binder aging than the short-term oven aging methods of asphalt mixtures.  相似文献   

10.
Load-carrying capacity of timber–concrete composite joints is usually evaluated using shear tests, which still lack specific standards. Regulations EN 26891 [1] and ASTM D 5652 [2] are usually used, both for timber joints, or EUROCODE 4 [3] for steel–concrete composite joints. Questions about test execution and arrangement of specimens are frequent and recurrent [4], [5], [6]. Steel–concrete composite structures already have a standard shear test for joints (push-out), described in Johnson and Anderson [7]. These authors also discussed the many differences in the results of shear tests because of differences in test methods before EUROCODE 4 [3] standardization.This paper presents some questions about the arrangement of test specimens for shear tests in timber–concrete joints. An experimental program was performed for this reason. The aim of the work was to compare shear test results using two different series of specimens most utilized in a review of the literature: the push-out type with concrete center and timber sides and the push-out type with timber center and concrete sides. 8.0, 10.0 and 12.5 mm diameter corrugated bars were used as connectors. Eucalyptus grandis Brazilian hardwood timber glulam was used. Two-component epoxy adhesive was used to glue the connectors into the timber. Average cylinder compressive strength of the concrete was 25 MPa (28 days old). Reinforcement was 6.0 mm diameter 500 MPa-yield-stress corrugated bars.The results showed that test specimen arrangement influenced the strength and deformation characteristics of timber–concrete composite joints. The specimen with the best shear strength was the concrete–wood–concrete type, similar to those used in steel–concrete composite structures. Since the arrangement of test specimen is an important factor in joint tests, it is recommended that further efforts be made towards standardization.  相似文献   

11.
Steel fiber-added reinforced concrete (SFRC) applications have become widespread in areas such as higher upper layers, tunnel shells, concrete sewer pipes, and slabs of large industrial buildings. Usage of SFRC in load-carrying members of buildings having conventional reinforced concrete (RC) frames is also gaining popularity recently because of its positive contribution to both energy absorption capacity and concrete strength.This paper presents experimental and finite element analysis of three SFRC beams. For this purpose, three SFRC beams with 250 × 350 × 2000 mm dimensions are produced using a concrete class of C20 with 30 kg/m3 dosage of steel fibers and steel class S420 with shear stirrups. SFRC beams are subjected to bending by a four-point loading setup in certified beam-loading frame, exactly after having been moist-cured for 28 days. The tests are with control of loads. The beams are loaded until they are broken and the loadings are stopped when the tensile steel bars are broken into two pieces. Applied loads and mid-section deflections are carefully recorded at every 5 kN load increment from the beginning till the ultimate failure.One of the SFRC beams modeled by using nonlinear material properties adopted from experimental study is analyzed till the ultimate failure cracks by ANSYS. Eight-noded solid brick elements are used to model the concrete. Internal reinforcement is modeled by using 3D spar elements. A quarter of the full beam is taken into account in the modeling process.The results obtained from the finite element and experimental analyses are compared to each other. It is seen from the results that the finite element failure behavior indicates a good agreement with the experimental failure behavior.  相似文献   

12.
Experimental tests conducted on 27 square cementitious slabs of 490 × 490 mm simply supported on four edges and subjected to patch load are presented. The slabs had a clear span of 400 × 400 mm and provided with a 445 × 445 mm closed frame of 8 mm diameter steel bar to hold the reinforcement in place and to act as a line support. The test variables were the wire mesh volume fraction: four expanded and two square types; slab thickness: 40, 45, 50 and 60 mm; and the patch load pattern: square and rectangular. The test results showed that as the volume fraction increased the punching strength of the slabs was also increased. Adding a wire mesh to ordinary reinforcement increases significantly the punching resistance at column stub. Moreover, as the loaded area size increases both ductility and stiffness increases and the bridging effect due to the difference in the reinforcement ratio in orthogonal directions was clearly noticed. More research was needed to identify the volume fraction ratio at which the mode of failure alter from flexure to punching.  相似文献   

13.
The experiments were performed for assessing the influence of cyclic thermal loading on the shear strength of reinforced concrete (RC) beam specimens. One hundred eleven RC beams of 100 × 150 × 1200 mm size reinforced in tension zone with two bars of 8, 10 and 12 mm diameters were tested under four point loading. The beams were subjected to a number of thermal cycles varying from 7 to 28 cycles with peak temperature taken as 100, 200 and 300 °C. The effects of thermal cycles on the crack pattern, failure mechanism, first crack load and the shear strength of beams have been discussed. The shear strength of the beams has been found to increase by up to 10% at lower temperature cycles of 100 and 200 °C but reduces by up to 14% at higher temperature (300 °C) depending on the severity of thermal loading. The results of study emphasize the need for developing appropriate guidelines for the design of RC structural elements used in comparatively high temperature environment with cyclic thermal loading conditions.  相似文献   

14.
Sixteen under-reinforced high strength concrete one-way slabs were cast, heated at 600 °C for 2 h, repaired, and then tested under four-point loading to investigate the coupling effect of water recuring and repairing with advance composite materials on increasing the flexural capacity of heat-damaged slabs. The composites used included high strength fiber reinforced concrete layers; and carbon and glass fiber reinforced polymer (CFRP and GFRP) sheets. Upon heating then cooling, the reinforced concrete (RC) slabs experienced extensive map cracking, and upward cambering without spalling. Recuring the heat-damaged slabs for 28 days allowed recovering the original stiffness without achieving the original load carrying capacity. Other slabs, recured then repaired with steel fiber reinforced concrete (SFRC) layers, regained from 79% to 84% of the original load capacity with a corresponding increase in stiffness from 382% to 503%, whereas those recured then repaired with CFRP and GFRP sheets, regained up to 158% and 125% of the original load capacity with a corresponding increase in stiffness of up to 319% and 197%, respectively. Control, heat-damaged, and water recured slabs showed a typical flexural failure mode with very fine and well distributed hairline cracks, propagated from the repair layers to concrete compression zone. RC slabs repaired with SFRC layers failed in flexural through a single crack, propagated throughout the compression zone, whereas those repaired with CFRP and GFRP experience yielding failure of steel prior to the composites failure.  相似文献   

15.
In this paper, applicability of previously published empirical relations among compressive strength, splitting tensile strength and flexural strength of normal concrete, polypropylene fiber reinforced concrete (PFRC) and glass fiber reinforced concrete (GFRC) to steel fiber reinforced concrete (SFRC) was evaluated; moreover, correlations among these mechanical properties of SFRC were analyzed. For the investigation, a large number of experimental data were collected from published literature, where water/binder ratio (w/b), steel fiber aspect ratio and volume fraction were reported in the general range of 0.25–0.5, 55–80 and 0.5–2.0%, respectively, and specimens were cylinders with size of Φ 150 × 300 mm and prisms with size of 150 × 150 × 500 mm. Results of evaluation on these published empirical relations indicate the inapplicability to SFRC, also confirm the necessity of determination on correlations among mechanical properties of SFRC. Through the regression analysis on the experimental data collected, power relations with coefficients of determination of 0.94 and 0.90 are obtained for SFRC between compressive strength and splitting tensile strength, and between splitting tensile strength and flexural strength, respectively.  相似文献   

16.
The in-plane shear behaviour of URM wallettes strengthened using near surface mounted high strength twisted stainless steel reinforcement (TSNSM) was investigated and in particular, the effectiveness of the reinforcing schemes to restrain the diagonal cracking failure mode was studied. A total of 17 URM wallettes, each being 1.2 m × 1.2 m in size, were structurally tested in induced diagonal compression. Of these, 3 wallettes were tested as-built and 14 wallettes were tested after being strengthened using different patterns of TSNSM bars. Several parameters pertaining to the in-plane shear behaviour of strengthened URM walls were investigated, including failure modes, shear strength, maximum drift, pseudo-ductility, and shear modulus. It was inferred from the results that as-built tested wallettes exhibited sudden post-peak strength degradation and failed along a stepped diagonal joint crack, whilst strengthened wallettes failed along distributed diagonal cracks in a more ductile fashion and exhibited a shear strength increment ranging from 114% to 189%.  相似文献   

17.
Mechanical behavior of a jointed rock mass with non-persistent joints located adjacent to a free surface on the wall of an excavation was simulated under without and with support stress on the free surface using approximately 0.5 m cubical synthetic jointed rock blocks having 9 non-persistent joints of length 0.5 m, width 0.1 m and a certain orientation arranged in an en echelon and a symmetrical pattern using PFC3D software package. The joint orientation was changed from one block to another to study the effect of joint orientation on strength, deformability and failure modes of the jointed blocks. First the micro-mechanical parameters of the PFC3D model were calibrated using the macro mechanical properties of the synthetic intact standard cylindrical specimens and macro mechanical properties of a limited number of physical experiments performed on synthetic jointed rock blocks of approximately 0.5 m cubes. Under no support stress, the synthetic jointed rock blocks exhibited the same three failure modes: (a) intact rock failure, (b) step-path failure and (c) planar failure under both physical experiments and numerical simulations for different orientations. The jointed blocks which failed under intact rock failure mode and planar or step-path failure mode produced high and low jointed block strengths, respectively. Three phases of convergence of free surface were discovered. The joint orientation and support stress played important roles on convergence magnitude. The average increment of jointed block strength turned out to be about 10, 7.9 and 6.6 times the support stress when support stresses of 0.06 MPa, 0.20 MPa and 0.40 MPa were applied, respectively. The modeling results offer some guideline in support design for underground excavations.  相似文献   

18.
《Energy and Buildings》2003,35(3):239-247
The system consists of a flat-plate collector and a storage tank. Flat-plate collector is made of galvanised steel tube and aluminium plate, with MAXORB selective surface, encased in a mild steel tray with top single glass cover, bottom has been provided with glass wool insulation. It is kept facing equator and at λ+15° tilt (λ latitude of the place).The double walled storage tank is of 100 l capacity. The inner drum is made of 18 gauge galvanised steel and outer of mild steel. Space (100 mm) between them is filled with glass wool insulation.Performance and testing of solar water heater has been carried out extensively. It has been found that the heater can provide 100 l of hot water at an average temperature of 60.6 °C at 16:00 h when tap water temperature was 23.6 °C, it can retain hot water till next day morning at an average temperature of 51.6 °C. The overall efficiency of the heater is 57%.Based on performance at Jodhpur, a model has been developed by using ambient temperature and solar radiation for the prediction of its performance at various Indian stations. The predicted performance at various Indian stations revealed that hot water is required at most places for domestic use only during winter season and it can provide 100 l of hot water at an average temperature of 50–70 °C that can be retained to 40–60 °C till next day morning use.  相似文献   

19.
This paper presents the results of an experimental program to investigate the effect of high temperature on the performance of concrete externally confined with FRP sheets. For this purpose, a two-phase experimental program was conducted. In the first phase, 42 standard 100 × 200 mm concrete cylinders were prepared. Out of these specimens, 14 cylinders were left unwrapped; 14 specimens were wrapped with one layer of CFRP sheet; and the remaining 14 specimens were wrapped with one layer of GFRP sheet. Some of the unconfined and FRP-confined specimens were exposed to room temperature; whereas, other cylinders were exposed to heating regime of 100 °C and 200 °C for a period of 1, 2 or 3 h. After high temperature exposure, specimens were tested under uniaxial compression till failure. The test results demonstrated that at a temperature of 100 °C (a little more than the glass transition temperature (Tg) of the epoxy resin), both CFRP- and GFRP-wrapped specimens experienced small loss in strength resulting from melting of epoxy. This loss of strength was more pronounced when the temperature reached 200 °C. In the second phase of the experimental program, three 100 × 100 × 650 mm concrete prisms were prepared and then overlaid by one layer of CFRP and GFRP laminates for conducting pull-off strength tests as per ASTM D4541 – 09. The objective of this testing was to evaluate the degradation in bond strength between FRP and concrete substrate when exposed to elevated temperature environments. One prism was exposed to room temperature whereas the other two specimens were exposed to heating regime of 100 °C and 200 °C for a period of 3 h. It was concluded that a significant degradation in the bond strength occurred at a temperature of 200 °C especially for CFRP-overlaid specimens.  相似文献   

20.
This paper focuses on the development of the compressive strength correlation between the individual block, prism and basic wall panel for load bearing interlocking hollow mortarless blocks. The interlocking blocks used were developed by the Housing Research Centre at Universiti Putra Malaysia. The blocks consisted of stretcher, corner and half blocks. Forty individual block units from each type were tested under compression. The compressive strengths of 10 prisms assembled by stacking two stretcher blocks and two half blocks were evaluated. In addition, four wall panels each having a dimension of 1.2 × 1.2 m were assembled and tested under axial compressive loads. The results obtained were compared with those found in bonded masonry. BS 5628 Part 1:1992 were used for predicting of the compressive capacity of the bonded masonry. The interlocking mechanism, crack patterns and failure mechanism of the interlocking masonry specimens are highlighted and discussed.The correlations between the compressive strength of the interlocking masonry individual block (fcb), prism (fcp) and standard panel (fcw) found in this analysis were fcp = 0.47fcb, fcw = 0.83fcp and fcw = 0.39fcb. Test results indicate that the interlocking mechanism and strength of the block in the load-bearing wall was satisfactory.  相似文献   