首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
在保持HRT、DO、pH值等参数基本不变的条件下,研究了不同进水COD浓度和C/N值对膜泥法一体化OCO工艺脱氮除碳效果的影响.研究表明,一体化OCO工艺对BOD5、COD均具有很好的去除效果,出水COD和BOD5浓度分别低于60和20 mg/L;随进水COD浓度和C/N值的增加,出水NH3-N浓度逐渐增大,去除率逐渐降低,而对总氮的去除率呈波浪式变化.进水COD为300 mg/L( C/N值为7.5左右)时的除污效果最好,此时系统对BOD5 、COD、NH3-N和TN的去除率分别达到98%、95%、98%和80%.该工艺有较强的降解有机污染物的能力和抗进水COD浓度和C/N值冲击的能力,能够满足处理城市生活污水的需要.  相似文献   

2.
以模拟生活污水为处理对象,研究了DO浓度和进水C/N值对中心岛式一体化OCO工艺脱氮除磷的影响。结果表明:当好氧区的DO浓度控制在2.0 mg/L左右时,缺氧区和厌氧区的DO浓度较易控制在反硝化和释磷所需的生化环境,对TN和TP均能达到较好的去除效果,去除率分别为85%和94%;随进水C/N值的增加,对TN的去除率先升高后降低,而对TP的去除率先升高后趋于稳定,对TN和TP的去除效果均在进水C/N值为8.5左右时最理想,去除率分别为85%以上和94%,当C/N值>8.5时,对TP的去除率基本保持在93%以上。  相似文献   

3.
基于An/O—SBR工艺,探讨了反应温度分别为15和25℃时,进水COD/TP(C/P)值对生物除磷系统的影响;并将进水总磷浓度恒定为(10±0.5)mg/L,以比较两温度下的厌氧段末释磷量和最终出水TP浓度。结果表明:在15和25℃下,随进水C/P值的升高,出水TP浓度降低,当C/P≥40时,出水TP1 mg/L;在25和15℃下,厌氧段释磷量与进水C/P值均呈线性相关;在进水C/P值相同的条件下,15℃时对TP的去除率比25℃时的平均高5%左右。  相似文献   

4.
研究了不同进水有机物浓度条件下,接种物不同的厌氧体系的同步脱硫反硝化特性。结果表明:当进水COD浓度从零增加到250mg/L时,两个接种物不同的反应器对硫化物、硝态氮和COD的去除率变化不同。接种厌氧污泥的1#反应器对硫化物的去除率从85%逐渐增加到99%,80%~90%的进水COD被去除,但产气量逐渐降低,出现了亚硝态氮的积累,反硝化脱氮困难;接种脱氮硫杆菌到厌氧污泥中的2#反应器对硫化物的去除率一直稳定在99%,相应的产气量也逐渐增大,脱氮效率高,55%~73%的进水COD被去除。此外,在这个浓度范围内,还观察到两个反应器出水硫酸盐的浓度由不加乙酸钠的23mg/L分别降到18mg/L和19mg/L,理论上硫转化率提高了4%~19%。当进水COD400mg/L时,仅60%~76%的硫化物被去除,相应的产气量也迅速降低,硫化物的氧化和反硝化过程均明显受到抑制。总而言之,在进水COD为250mg/L时,2#反应器对硫化物和硝态氮的去除率均达到了100%左右,对硫化物的比降解速率和产气量也提高了1.1~1.2倍,相应的出水硫酸盐浓度最低,80%左右的硫化物转化为单质硫,73%的COD被去除,可以实现同时脱氮、除硫和除碳,为同步脱氮除硫工艺的实际应用提供了新的思路。  相似文献   

5.
针对现有自养硝化过程效能低的问题,以高盐高氮高有机物浓度榨菜废水为研究对象,考察了C/N值对基于异养硝化的压力生物膜反应器同步脱氮系统效能的影响。采用16S rDNA与PCR-DGGE技术探讨了C/N值对系统微生物种群的影响。结果表明:对COD为8 960 mg/L、NH+4-N为175 mg/L、TN为185 mg/L的高盐废水,C/N值对系统的脱氮效能影响显著,在盐度为3%(以NaCl计)、温度为(35±0.5)℃、C/N值为50、有机负荷为23.04 kgCOD/(m3·d)、氮负荷为0.48 kgN/(m3·d)时,对COD、NH+4-N、TN的去除率分别为97.87%、98.93%、98.18%。在高负荷条件下,反应器中氮和有机物呈现同步降解的规律,表明系统中的硝化过程为异养硝化。同时,C/N值对系统微生物的群落结构有影响,C/N值过高或过低时微生物种群丰富度和多样性指数值均有所降低;但不同C/N值条件下的微生物种群有较高的相似性。  相似文献   

6.
针对低碳源生活污水(COD/TN值<5,COD<200 mg/L)脱氮除磷效果差的问题,设计并运行了一套具有强化反硝化除磷功能的反应器。该反应器结合污泥外循环侧流除磷、剩余污泥碱解技术,并强化反硝化吸磷功能,采用好氧/缺氧交替运行方式。结果表明:在进水COD、TN、NH3-N、TP平均浓度分别为151、31.37、24.80、5.72 mg/L,C/N、C/P平均值分别为4.81、26.99的情况下,系统具有稳定的脱氮除磷效果,出水COD、TN、NH3-N、TP平均浓度分别为20.63、13.25、0.68和0.10 mg/L,平均去除率分别为86.31%、57.80%、97.26%和98.18%。  相似文献   

7.
一体式膜生物反应器的脱氮除磷效能研究   总被引:3,自引:2,他引:1  
采用一体式膜生物反应器处理城市生活污水,考察了不同溶解氧浓度下的脱氮除磷效果.结果表明,在低溶解氧条件下,膜生物反应器在有效去除有机物的同时还取得了较好的脱氮除磷效果.当控制反应器内溶解氧为0.5 ms/L左右时,进水COD为342~2 500 mg/L.出水COD平均为31.71 mg/L,对COD的去除率可达95%以上;进水TP为4.08~31.45 mg/L,出水TP70%.当溶解氧>2 mg/L时,进水COD为161.3~453.4 mg/L,出水COD为8.32~21.9 mg/L,去除率最高可达99.08%;进水TN为22.52~57.9 mg/L,出水TN为16.3l~24.49 mg/L,对TN的去除率大多为30%~40%;进水TP平均为4.48 mg/L,出水TP大部分在1.0 ms/L以上,去除率为48.07%~93.22%.  相似文献   

8.
针对现有城镇污水脱氮除磷效率低、碳源对深度脱氮除磷制约等突出问题,提出了基于短时曝气SBR的城镇污水高标准脱氮除磷技术,考察了进水C/N值对短时曝气SBR脱氮除磷效能的影响。结果表明,进水C/N值对短时曝气SBR的脱氮除磷效能影响显著。当温度为25℃,SRT为40 d,进水C/N值分别为4、5、6、7时,系统对NH4+-N的平均去除率分别为83.3%、99.3%、99.4%、99.5%,对TN的平均去除率分别为58.8%、82.6%、88.1%、93.8%,对TP的平均去除率分别为14.6%、54.5%、76.6%、97.5%。当进水C/N值为7时,系统出水COD、NH4+-N、TN、TP平均浓度分别为18、0.20、2.46、0.13 mg/L,COD、NH4+-N与TP指标满足地表水Ⅳ类水质标准,TN指标接近地表水Ⅴ类水质标准。  相似文献   

9.
分段进水SBR处理低C/N值含盐废水的脱氮效果   总被引:1,自引:0,他引:1  
针对低C/N值含盐废水利用传统生物脱氮工艺处理时存在有机碳源不足、脱氮效率低的问题,提出以优先利用原水中的可生物降解有机物和减少外加碳源为目的的分段进水SBR工艺。对比分析了5种不同进水方式下的脱氮效率、N2O释放量及转化率,结果表明:在外碳源充足的条件下,5种进水方式均可实现较好的脱氮效果,但进水比例为1∶2∶3的三段式进水脱氮过程中N2O的转化率较一段进水方式减少了约46%。在二段进水方式中,进水比例为1∶1的N2O转化率最高,达到了5.1%,而进水比例为1∶2的仅有2.5%。对比最后一次硝化结束时系统内的NOx--N浓度,一、二、三段式的分别为41.5、23.3、19.7 mg/L,因此通过分段进水可节省后续反硝化时间和反硝化外碳源需求量。可见,当处理低C/N值含盐废水时,采用适当的分段进水方式和进水比例,可在实现高效脱氮、降低运行成本的同时防止N2O的大量释放。  相似文献   

10.
生物接触氧化法的同步硝化反硝化影响因素研究   总被引:2,自引:0,他引:2  
研究了生物接触氧化法同步硝化反硝化系统中HRT、DO、COD及生物膜厚度对脱氮效率的影响.结果表明:在DO=2.0 mg/L的条件下,出水COD、TN、NH+4-N值随HRT的增加呈下降趋势,在HRT达到8 h时,出水COD、TN、NH+4-N值趋于稳定,去除率分别为94%、55.9%和73.3%;5-DO为2.0~4.0 mg/L范围内,对TN的去除率随着反应器内DO浓度的降低呈上升趋势,保持较好脱氮率的溶解氧为2.5~3.0 mg/L;进水COD为400 mg/L时,系统对TN、NH+4-N的去除率及容积去除率都处在较高水平,对TN的平均去除率达到60%;生物膜厚度对同步硝化反硝化有较大影响,增加生物膜厚度有利于同步硝化反硝化的进行.  相似文献   

11.
低溶氧下低C/N值生活污水的同步硝化反硝化   总被引:5,自引:1,他引:5  
采用改良的Orbal氧化沟中试系统处理低C/N值生活污水,考察了溶解氧浓度对同步硝化反硝化(SND)的影响。结果表明,当外沟溶解氧浓度为0.3mg/L时,约有29.97mg/L的总氮在氧化沟的外沟通过SND去除,外沟对COD的实际去除量为9.03mg/L,外沟的SND主要是利用微生物内贮有机碳源或生物吸附碳源进行的。控制氧化沟的外、中、内沟溶解氧浓度分别为0.3、0.5和2.0mg/L时,系统的SND率和总氮去除率最高。在优化的溶解氧条件下,系统对总氮的平均去除率和平均SND率分别为66.0%和42.6%,分别比优化前提高了13.8%和24.3%。  相似文献   

12.
Effects of influent COD/N ratio on N2O emission from a biological nitrogen removal process with intermittent aeration, supplied with high-strength wastewater, were investigated with laboratory-scale bioreactors. Furthermore, the mechanism of N2O production in the bioreactor supplied with low COD/N ratio wastewater was studied using 15N tracer method, measuring of reduction rates in denitrification pathway, and conducting batch experiments under denitrifying condition. In steady-state operation, 20-30% of influent nitrogen was emitted as N2O in the bioreactors with influent COD/N ratio less than 3.5. A 15N tracer study showed that this N2O originated from denitrification in anoxic phase. However, N2O reduction capacity of denitrifiers was always larger than NO3(-)-N or NO2(-)-N reduction capacity. It was suggested that a high N2O emission rate under low COD/N ratio operations was mainly due to endogenous denitrification with NO2(-)-N in the later part of anoxic phase. This NO2(-)-N build-up was attributed to the difference between NO3(-)-N and NO2(-)-N reduction capacities, which was the feature observed only in low COD/N ratio operations.  相似文献   

13.
龚安军  刘氚 《山西建筑》2011,37(15):106-108
采用CASS工艺对低碳氮比生活污水进行处理研究,试验结果表明:通过外加甲醇将碳氮比调整到5∶1,排水比50%,混合液回流比100%的情况下,最佳运行工况为充水曝气6 h,沉淀1 h,滗水0.5 h,静置0.5 h,在进水COD为210 mg/L-375 mg/L,TN为52 mg/L-62 mg/L,TP为1.9 mg/L-2.9 mg/L,SS为100 mg/L-202 mg/L的情况下,出水COD为5 mg/L-50 mg/L,TN为10 mg/L-21 mg/L,TP为0.5 mg/L-1.2 mg/L,SS为6 mg/L-19 mg/L,出水各项指标稳定且达到排放标准。  相似文献   

14.
潜流人工湿地深度净化二级处理出水研究   总被引:3,自引:0,他引:3  
采用页岩/钢渣强化潜流人工湿地深度净化城市污水厂二级处理出水,结果表明,在平均水力负荷为0.32m/d的条件下,当进水COD、TN、TP平均浓度分别为33.9、15.1、1.57mg/L时,出水COD平均浓度为13.2mg/L,去除率为61%,面积反应速率常数(K)值为0.3m/d,温度对去除COD的影响不明显;出水TN浓度在5.4—14.3mg/L之间波动,瓦值为0.09—0.31m/d,去除率受温度的影响很大,随着进水硝态氮所占比例的提高和运行时间的延长,湿地对TN的去除率有上升趋势;稳定阶段出水TP浓度为0.6mg/L,去除率为50%,瓦值为0.26m/d,温度对去除TP的影响不大。  相似文献   

15.
SBR无厌氧段生物强化除磷的诱导研究   总被引:3,自引:0,他引:3  
采用SBR工艺处理人工配水,考察了进水COD及氨氮浓度、C/N值、好氧时间对诱导无厌氧段生物强化除磷的影响.结果表明,当以醋酸钠为碳源、进水COD和氨氮分别为100和5mg/L、C/N值为20时,对在A/O运行方式下表现为厌氧释磷、好氧超量吸磷的SBR,逐渐缩短其厌氧时间且保持好氧时间为135 min后,好氧吸磷现象并不会消失,仅是吸磷量略有降低.该除磷现象的发生是系统微生物经过特定诱导的结果.  相似文献   

16.
采用UCT工艺处理低C/N值城市污水,考察了其处理效果及影响因素。结果表明:UCT工艺对COD的平均去除率为87.3%,进水中较高浓度的氨氮对COD去除效果有一定的影响;系统运行稳定后,对氨氮的去除率可保持在90%以上,硝化效果较好;在无外加碳源的情况下,UCT工艺对总氮的去除率为50%左右,投加甲醇碳源调节污水的C/N值为6.2左右时,对总氮的去除率可稳定在80%以上;进水中较高浓度的氨氮对系统除磷效果的影响较大,在硝化效果不好的情况下对总磷的去除率可达86%,在硝化效果较好的情况下除磷效率较低,为50%左右。  相似文献   

17.
保健药制药废水处理工程设计   总被引:2,自引:1,他引:1  
针对保健药品制药废水浓度高、色度大的特点,采用水解酸化/生物接触氧化/混凝沉淀工艺进行处理,处理水量为 100 m3/d,进水COD约为1 200 mg/L、BOD5约为600 mg/L、SS约为600 mg/L、氨氮约为45 mg/L、色度为700倍.运行结果表明,出水COD、BOD5、SS、氨氮和色度分别为 82.0、18.2、32.0、12.0 mg/L和40倍,符合<污水综合排放标准>(GB 8978-1996)的一级标准.该工艺处理效果稳定,耐冲击负荷能力强,产泥量少.  相似文献   

18.
MBR中DO对同步硝化反硝化的影响   总被引:60,自引:12,他引:48  
膜生物反应器(MBR)中,在DO为1mg/L左右,MLSS为8000-9000mg/L,温度为24℃,进水pH值为7.2,COD、NH3-N分别为523-700mg/L和17.24-24mg/L的相对稳定条件下,对COD、NH3-N、TN的去除率分别为96%、95%、92%。详细分析了在控制DO的条件下,MBR发生同步硝化、反硝化的原因,并提出了在单级好氧反应器中控制DO可发生短程硝化一反硝化生物脱氮的机制。  相似文献   

19.
In the modified Ludzack–Ettinger process, high‐energy input is required in a nitrification tank. To address this issue, a new biological nitrification–denitrification system was constructed with a trickling filter for nitrification. The effects of recirculation rate of nitrified liquor and temperature through the treatment of municipal wastewater were evaluated. The highest DN removal efficiency was observed at 6.5 h of hydraulic retention in the denitrification tank and 350% of recirculation rate of nitrified liquid against the influent flow rate. The DN removal efficiencies did not reach theoretical values for all conditions tested because the COD/N ratios in the influent often decreased to less than 5 g‐COD/g‐N and temperatures dropped to less than 15°C in winter. The former inhibited the denitrification process and the latter significantly decreased the bioactivity of nitrifying bacteria. As such, this system is suitable in tropical and subtropical areas with annual minimum temperatures of over 15°C.  相似文献   

20.
研究了连续流三维电极/生物膜反应器在不同氮磷比(N/P)下的反硝化性能。结果表明:N/P值对去除NO3--N的影响不大,但对出水NO2--N浓度有明显影响。在N/P值由5∶1增大至100∶1的过程中,对NO3--N的去除率介于59.2%~71.6%之间。当N/P值为10∶1时,对NO3--N的去除率最高达到了71.6%,出水NO3--N为8.53 mg/L。当N/P值为10∶1时,出水NO2--N浓度最低为0.27 mg/L;当N/P值为100∶1时NO2--N的积累最为严重,NO2--N生成量最高达到了1.76 mg/L。N/P值还对NH4+-N的产生有明显影响,N/P值从5∶1增至100∶1的过程中,NH4+-N生成量由4.50 mg/L逐渐减小至0.26 mg/L。当N/P值为(5∶1)~(50∶1)时,反应器具有较好的除磷功能;但当N/P值为100∶1时,出水TP浓度高于进水TP浓度。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号