首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
This paper reports on an experimental programme to investigate the effect of using ground copper slag (GCS) as a replacement of cement on the fresh properties of self-consolidating concrete (SCC). Totally, seven self-compacting ground copper slag concrete (SCGCSC) mixtures were made with a fixed water–powder ratio of 0.51 in which a portion of the cement was replaced by GCS in weight ratios of 0%, 5%, 10%, 15%, 20%, 25% and 30%. The fresh properties were investigated by slump-flow, visual stability index, V-funnel, J-ring, L-box, air content, screen stability and setting time tests. The SCGCSCs were designed to give a constant slump flow of 680 ± 30 mm which was achieved by using the super-plasticiser at varying amounts. This allowed us to have a reasonable comparison of the obtained results. Totally, it has been concluded that using GCS significantly increased the workability of SCC mixtures. As the GCS increased, the slump flow is also increased at a constant amount of water and super-plasticiser, but the time required to flow is decreased. The results showed that it is possible to successfully produce SCC with GCS as cement replacement.  相似文献   

2.
进行了两榀预应力型钢混凝土框架和非预应力型钢混凝土框架在竖向荷载及水平低周反复荷载作用下受力与抗震性能试验研究,研究结果表明:在型钢混凝土梁中采用预应力,可以有效地控制结构裂缝宽度,改善结构的正常使用性能;梁中施加预应力没有明显改变型钢混凝土结构优良的抗震性能,预应力型钢混凝土框架低周反复加载滞回曲线饱满,抗震性能优良;在型钢混凝土梁中施加预应力,可以充分发挥型钢与混凝土等材料各自的优势。在试验研究的基础上,提出了预应力型钢混凝土框架和型钢混凝土框架的三线型恢复力模型,并利用该恢复力模型进行了预应力型钢混凝土框架和型钢混凝土框架在低周反复荷载作用下的滞回性能分析,分析结果与试验结果吻合良好。  相似文献   

3.
钢筋混凝土剪力墙抗震恢复力模型及试验研究   总被引:22,自引:0,他引:22       下载免费PDF全文
通过拟静力试验,对9片钢筋混凝土剪力墙分别进行了在周期反复荷载作用下受力性能的研究,验证了本文提出的钢筋混凝土剪力墙的多弹簧宏观有限元模型,进而得到了荷载与位移关系更合理的本构模型,给出了相应的计算公式。通过比较不同轴压比和不同剪跨比的剪力墙的破坏形态、破坏程度,以及对试验现象和滞回曲线的分析,得到如下结论:随着轴压比在一定范围内的提高,相同剪跨比的剪力墙其承载能力有一定程度的提高,但墙体的延性下降,强度退化和刚度退化趋于严重。随着剪跨比的提高,相同轴压比的试件破坏形态由剪切破坏向弯曲破坏过渡,承载能力随之降低,但试件的延性提高,耗能能力大大加强。  相似文献   

4.
高温后钢筋混凝土短柱抗震性能试验研究   总被引:1,自引:0,他引:1  
通过对7根高温后钢筋混凝土短柱试件和1根常温对比试件的拟静力试验,研究受火时间、轴压比和剪跨比对火灾后钢筋混凝土短柱的破坏形态、受剪承载力、骨架曲线、刚度退化、延性比、滞回耗能等的影响。利用有限元程序计算了高温后截面混凝土抗压强度的平均折减系数,提出了四周受火后钢筋混凝土柱受剪承载力的计算方法。研究结果表明:高温后短柱的受剪承载力随受火时间的增加、剪跨比的增大而减小;剪跨比对受火前后受剪承载力影响变化的程度相差较小;高温后短柱的受剪承载力先随轴压比的增大而增大,但当轴压比增大至界限轴压比后,受剪承载力反将降低,且高温后柱的界限轴压比较未受火时有减小趋势;提出的高温后钢筋混凝土柱受剪承载力计算式具有一定的安全保证率,可用于火灾后该类构件受剪性能的损伤评定。  相似文献   

5.
通过对不同轴压比下截面边长分别为300、500、700mm的钢筋混凝土柱试件进行低周反复加载试验,研究各试件的破坏模式、滞回特性、骨架曲线、延性和耗能能力,分析截面尺寸对受弯承载力、延性、耗能和塑性铰长度的影响。结果表明:钢筋混凝土柱试件的受弯承载力、延性和塑性铰转动能力随截面尺寸的增大而减小,尺寸效应明显,平均耗能系数也随截面尺寸的增大而减小,表现出明显的尺寸效应。在试验基础上,提出考虑反复加载截面尺寸影响系数的钢筋混凝土柱受弯承载力计算式。  相似文献   

6.
为研究型钢超高强混凝土柱的抗震性能,开展了27根型钢超高强混凝土柱试件的低周反复加载试验。试件设计参数为剪跨比、轴压力水平、配箍、型钢和栓钉配置情况。针对不同设计参数的试件的破坏特征、滞回曲线、水平承载力、耗能能力及变形能力、承载力及刚度退化等进行了分析,得到了各设计参数的影响规律。试验结果表明:型钢超高强混凝土柱的滞回曲线饱满且较稳定;剪跨比较大、轴压比较低、箍筋有效约束指标较大、配置H型或十字型钢的试件具有更好的抗震性能;型钢在箍筋约束效果较好时,能更充分地发挥提高柱抗震性能的作用;通过配置高强度八边形复合箍筋,能有效避免型钢超高强混凝土短柱发生脆性剪切破坏,使得其最终破坏形态为弯曲破坏,从而改善其抗震性能;配置栓钉能提高柱的抗震性能,且当柱的变形能力较强时效果更明显;试验轴压比为0.38或0.45的试件仍具有较强的耗能能力和变形能力,即型钢超高强混凝土柱具有较好的抗震性能。  相似文献   

7.
型钢混凝土异形柱框架节点抗震性能试验研究   总被引:5,自引:4,他引:5       下载免费PDF全文
为研究型钢混凝土(SRC)异形柱框架节点的破坏特征和抗震性能,进行了9个中间层边节点、4个角节点和4个中节点的低周反复荷载试验。观察了各类型节点的受力过程及破坏形态,并分析了试件的荷载-位移滞回曲线、承载能力、层间位移角和延性以及耗能能力等力学特性。结果表明:SRC异形柱框架节点的典型破坏形态是节点核心区剪切斜压破坏和梁端弯剪破坏;滞回曲线饱满,层间位移角延性系数及位移延性系数介于1.80~5.63,弹塑性极限层间位移角约为1/67~1/28,等效粘滞阻尼系数介于0.150~0.294,破坏时节点核心区的剪切角约为0.03~0.04。并给出了节点设计建议。  相似文献   

8.
通过对6层适量注芯混凝土小型空心砌块配筋砌体结构模型进行地震模拟振动台试验,分析结构体系的结构动力特性、加速度放大反应、最大层间位移角等,研究其在抗震设防烈度为7度构造措施条件下的结构抗震性能、屈服机制。试验结果表明:配筋砌体模型结构在地震作用下的整体变形仍以剪切变形为主;在输入不同地震波、不同峰值加速度时,结构横向所能承受的输入峰值加速度的平均值比纵向要高,横向变形大于纵向变形,说明结构纵向抗震能力要强于横向;圈梁、构造柱以及水平拉结筋构成的约束体系作用明显,结构在基本烈度地震作用下抗破坏能力较强,能够满足抗震规范规定的在7度区“大震不倒”的要求;结构在罕遇地震作用下也具有相当的抗震能力。  相似文献   

9.
钢筋混凝土开洞叠合剪力墙抗震性能试验研究   总被引:5,自引:0,他引:5  
通过对4片钢筋混凝土开洞叠合剪力墙和2片普通钢筋混凝土开洞剪力墙进行抗震性能试验研究,对比研究了试件的受力全过程、开裂部位、裂缝发展情况以及破坏形态,分析了试件的承载能力、滞回曲线、骨架曲线、刚度退化曲线、延性性能、耗能能力等。研究结果表明:钢筋混凝土开洞叠合剪力墙的受力性能基本和普通钢筋混凝土开洞剪力墙相同,具有较好的抗震性能;保温层外侧的预制钢筋混凝土板能够协同参与受力,与普通钢筋混凝土开洞剪力墙相比,其承载力可提高约7%,并可有效降低其刚度退化;剪式支架能使钢筋混凝土开洞叠合剪力墙的预制部分与现浇混凝土形成整体,共同参与工作。  相似文献   

10.
模拟近海大气环境对5榀不同设计参数的低矮RC剪力墙试件进行加速锈蚀试验,达到预期锈蚀目标后,对锈蚀试件进行拟静力试验,旨在研究不同水平分布筋间距和不同暗柱纵筋直径对锈蚀低矮RC剪力墙承载力、变形能力及剪切滞回特性等抗震性能的影响。结果表明:沿暗柱纵筋的锈胀裂缝较沿水平分布筋和暗柱箍筋的宽,而水平分布筋和暗柱箍筋的锈蚀率则比暗柱纵筋的大;随着水平分布筋间距的减小,锈蚀试件剪切破坏程度降低,剪切变形减小,而试件承载力、延性和耗能分别有不同程度的提高,其中以延性提高幅度最大;随着暗柱纵筋直径的增大,锈蚀试件受弯能力得到较大提升,剪切破坏程度增加,剪切变形增大,试件承载力、延性和耗能亦分别有不同程度的提高,其中承载力提高最多,延性和耗能提高相对较少。  相似文献   

11.
为研究分散型钢混凝土组合柱(ISRCC)的抗震性能,分析组合柱中分散布置的型钢和混凝土之间的协同工作情况,对4个ISRCC柱进行偏心率为10%和15%的低周往复加载试验。与传统低周往复加载试验相比,试验中按预定路径同时施加竖向荷载和水平荷载。分析了ISRCC柱在低周往复荷载作用下的承载力、延性、破坏形态、裂缝分布和刚度退化等。试验结果表明:所有ISRCC柱均为小偏心压弯破坏,试件整体性较好;在偏心率15%以内,屈服荷载前各试件满足平截面假定,能够有效发挥型钢和混凝土的组合作用;ISRCC柱压弯承载力的试验值与ACI 318-2014、EN 1994-1-1和YB 9082-2006《钢骨混凝土结构技术规程》等规范中的承载力计算结果吻合较好,验证了现有规范中普通钢骨混凝土(SRC)柱压弯承载力的计算方法对偏心率15%以内的ISRCC柱的适用性;试件的极限位移角为1/88~1/65,满足我国规范对罕遇地震作用下框架-核心筒结构弹塑性层间位移角的要求,具有较好的变形能力。  相似文献   

12.
火电厂主厂房型钢混凝土混合结构中存在由于错层、变梁变柱截面引起的异型中节点,选取5个代表性节点进行1∶5缩尺拟静力试验,研究该类节点的滞回性能、耗能能力、延性、刚度退化以及承载能力。研究结果表明:受强梁弱柱特性的影响,4个型钢混凝土异型中节点主要发生不利于抗震的柱端塑性铰破坏,而钢筋混凝土异型中节点由于梁柱刚度比较大主要发生核心区剪切破坏;大小梁错层高度对型钢混凝土异型中节点的承载力、延性性能与刚度特性均有一定的影响,但规律并不明显;型钢混凝土柱-钢筋混凝土梁异型中节点的耗能能力强于钢筋混凝土异型中节点,但受破坏模式的影响,其承载能力、延性与刚度等均低于钢筋混凝土异型中节点;相比采用钢筋混凝土梁的型钢混凝土异型中节点,采用型钢混凝土梁的型钢混凝土异型中节点的开裂荷载高,初始刚度较大,但承载力、延性与耗能能力并未得到明显提高。  相似文献   

13.
多层砌体填充墙框架结构抗震性能试验研究   总被引:1,自引:0,他引:1  
为了研究砌体填充墙沿框架层不连续布置对框架结构抗震性能的影响,进行了3榀两层单跨砌体填充墙框架结构模型、1榀单层单跨砌体填充墙框架结构模型、1榀两层单跨框架结构模型和1榀单层单跨框架结构模型的对比试验,分析了各试件的破坏特征、滞回曲线、骨架曲线、位移延性、刚度退化、承载力退化和耗能性能等抗震性能指标。结果表明:无论是单层单跨还是两层单跨的砌体填充墙框架结构,其水平峰值荷载和初始刚度比相应的纯框架结构均有较大幅度的提高,且其刚度退化程度比相应纯框架结构要缓慢;砌体填充墙的存在提高了框架结构的抗侧刚度和水平峰值荷载,使框架结构的变形由剪切型逐渐转变为弯剪型;砌体填充墙参与了结构的滞回耗能,填充墙框架的位移延性和累积耗能能力明显优于框架;砌体填充墙沿框架层不连续布置会引起框架结构层间侧移刚度和层间受剪承载力发生突变,影响框架结构的破坏形态,但由于砌体填充墙参与了框架结构的滞回耗能,故其仍具有较好的抗震性能。  相似文献   

14.
为研究钢筋混凝土Z形截面双向受剪柱的抗震性能,对4个缩尺比为1/2的试件进行拟静力试验,分析不同水平加载方向(加载角α分别取0°、45°、90°、135°)对其抗震性能的影响,研究Z形截面柱的破坏形态,得到试件的荷载-位移滞回曲线、骨架曲线、承载力、位移延性系数、刚度退化和耗能能力等力学性能指标。研究结果表明:试件在水平反复荷载作用下的破坏形态为弯剪破坏、弯曲破坏、剪切黏结破坏和剪切斜压破坏,其中剪切破坏的试件延性较差;双向水平荷载作用方向对Z形截面柱受剪承载力的影响近似符合椭圆规律,在加载角为45°时,试件的耗能能力最强,当加载角为0°和135°时,试件的耗能能力相差不大。提出钢筋混凝土Z形截面柱双向受剪承载力的计算方法,按该方法对本次试验和已有试验共22个试件进行计算,计算结果与试验值吻合较好。  相似文献   

15.
目前大量既有多层砌体结构住宅面临增设电梯、成套改造等功能性改造的需求,利用功能性改造时后加的混凝土墙提高既有多层砌体结构的抗震性能是一种有益的探索。文中提出了三种后加混凝土墙与砌体墙的连接方式,并进行了7个后加混凝土-砌体组合墙体试件及其对比试件的低周反复加载试验,研究了其破坏模式、滞回性能、承载能力、变形能力、耗能与延性等。试验结果表明:三种连接方式均能有效保证后加混凝土墙与砌体墙的协同工作,其中植筋连接方式最为简便实用;后加混凝土墙不对称布置时,正、反两个方向的刚度退化过程不同但承载能力和变形能力无明显差异;增设混凝土墙后砌体墙的承载能力、变形和耗能能力大幅度提升,刚度退化明显改善;组合墙体中后加混凝土墙和砌体墙的抗剪能力均能充分发挥。基于黏性界面模拟砂浆层的分离式三维实体有限元分析方法能够较好地模拟组合墙体试件的骨架曲线和破坏形态。根据试验结论提出的受剪承载力计算公式与试验结果吻合良好。  相似文献   

16.
通过对1榀柱中内置型钢和1榀梁柱均内置型钢的预应力型钢混凝土框架的竖向反复荷载试验, 研究预应力型钢混凝土框架的破坏机制、滞回特性、延性、刚度和耗能等性能。结果表明:预应力型钢混凝土框架梁是梁铰破坏机制,极限状态时 “拱效应”提高了框架梁的承载能力;预应力型钢混凝土框架梁滞回曲线饱满,变形恢复能力小于普通预应力混凝土框架梁;预应力型钢混凝土框架梁位移延性系数均值为4.8,普通预应力混凝土框架梁的为4.18,均有较好的延性;等效黏滞阻尼系数介于0.258~0.323之间,说明2个试件破坏时截面具有良好的耗能能力;参数分析表明,试件延性系数受含钢率影响不大,随内置型钢截面高度与梁截面高度比值增大而增大。  相似文献   

17.
刘蓉 《山西建筑》2012,38(5):77-78
详细分析了钢筋混凝土框架结构体系建筑在地震中的破坏特征、破坏机理,并结合我国目前的抗震设防现状和国外发达国家的抗震经验,给出了提高结构抗震能力的措施,对于提高RC框架建筑的抗震性能和减少或避免地震引起的损失具有一定的指导意义。  相似文献   

18.
为研究预应力型钢混凝土双坡框架的抗震性能和破坏机理,基于同等承载能力条件设计缩尺比为1∶4的1榀预应力混凝土双坡框架(PC-F)和1榀预应力型钢混凝土双坡框架(PSC-F),并对其进行竖向荷载和水平低周反复荷载共同作用下的加载试验,得到框架的裂缝开展和分布及破坏形态特征、滞回曲线、骨架曲线、延性、刚度退化、等效黏滞系数、总耗能和位移恢复能力等抗震性能指标。试验结果表明:同等承载力条件下,预应力型钢混凝土双坡框架具有更优越的抗剪能力和抗震性能;相较于预应力混凝土双坡框架,预应力型钢混凝土双坡框架的开裂荷载提高了70%;型钢的存在使得预应力混凝土双坡框架的破坏机制由两铰(柱-斜坡梁节点)破坏转变为四铰(柱-斜坡梁节点、斜坡梁-水平梁节点)破坏,每个塑性铰部位呈现典型的弯曲延性破坏特征;相较于预应力混凝土双坡框架,预应力型钢混凝土双坡框架滞回环近似梭形更加饱满,峰值荷载后承载力退化及刚度退化更加缓慢,位移延性系数、等效黏滞阻尼系数、总耗能分别提高了9.27%、30.6%、53.5%,位移恢复能力系数降低27.5%。  相似文献   

19.
为研究水泥聚苯模壳(EPSC)格构式混凝土填充墙钢筋混凝土(RC)框架的抗震性能,对一足尺单层EPSC格构式混凝土填充墙RC框架模型进行了振动台试验。试验中考虑了墙体开洞及墙体与RC框架的连接方式,研究了不同强度地震动作用下模型结构的动力特性、加速度反应、位移反应、层间剪力和动应变反应。研究结果表明:连续强震动作用下EPSC裂缝数量较多,部分格构柱水平开裂,而RC框架未发现损伤,EPSC格构式混凝土填充墙RC框架具有良好的抗震性能;模型最大层间位移角仅为1/513,格构式混凝土墙体的存在极大增强了RC框架的抗侧刚度;墙体与RC框架设置不同间距、长度的拉结筋均能提高墙体的平面外稳定性能,可控制墙体与框架协同工作。  相似文献   

20.
郑文邦 《山西建筑》2006,32(15):54-55
论述了与配筋混凝土砌块砌体小高层框支结构相关的剪力墙及房屋抗震设计和性能的研究进展概况,介绍了其需要重点研究的几个方面,促进其在抗震设计中广泛地应用。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号