首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 171 毫秒
1.
In membrane bioreactors (MBRs) for wastewater treatment, membrane fouling, particularly biofouling caused by soluble microbial products (SMP), is a nuisance problem causing decreases in permeation flux. In a previous study, we identified primary biofoulants of microfiltration (MF) membranes in SMP as polysaccharides containing uronic acids that undergo inter- and intramolecular ionic cross-linking by polyvalent cations, forming a gelatinous mass that clogs membrane pores. In the present study, we therefore attempted to isolate biofoulant-degrading microorganisms from activated sludge on a polygalacturonic acid-overlaid agar medium and evaluate their efficiency for preventing biofouling of MF membranes. Among the isolates, the fungal strain HO1 identified as Phialemonium curvatum degraded 30% of polysaccharides containing uronic acids into smaller molecules in a SMP solution containing a high concentration of saccharides after 30 days of cultivation. Microfiltration tests using a laboratory-scale submerged MBR indicated that the filtration resistance of this degraded SMP solution was lower than that of the control SMP solution without fungal inoculation. Importantly, accumulation of gelatinous mass on the membrane responsible for biofouling was avoided in the SMP solution augmented with P. curvatum HO1 during the microfiltration test. This is the first report to describe a new method for avoiding biofouling of MBRs by microbial degradation of primary biofoulants.  相似文献   

2.
For more efficient control and prediction of membrane biofouling in membrane bioreactors (MBRs), a fundamental understanding of mechanisms of membrane biofouling is essential. In this study, we operated full-scale submerged MBRs using real municipal wastewater delivered from the primary sedimentation basin of a municipal wastewater treatment facility over 3 months, and the adhesion and formation of biofilms on 0.4-microm pore size polyethylene hollow-fiber microfiltration (MF) membrane surfaces, separated from simple deposition of sludge cake, were monitored using scanning electron microscopy (SEM). In addition, the compositions of planktonic and biofilm microbial communities in the MBR were analyzed using culture independent molecular-based methods (i.e., fluorescent in situ hybridization (FISH) and 16S rRNA gene sequence analysis). The SEM and LIVE/DEAD staining analyses clearly showed that the biofilms gradually developed on the membrane surfaces with time, which had a strong positive correlation with the increase in trans-membrane pressure (TMP). This indicated that the biofilm formation induced the membrane fouling. The FISH results revealed that the microbial communities on membrane surfaces were quite different from those in the planktonic biomass in the mixed liquor. Moreover, FISH and 16S rRNA gene sequence analyses revealed that a specific phylogenetic group of bacteria, the Betaproteobacteria, probably played a major role in development of the mature biofilms, which led to the severe irreversible membrane biofouling.  相似文献   

3.
A limiting factor for the reuse and recycling of treated tannery wastewater for irrigation and other uses is the high salt content, which persists even after conventional treatment. Reverse osmosis (RO) membrane treatment has been shown to significantly reduce the salt contents of tannery effluents. However, the high organic content of tannery effluent leads to rapid scaling and biofouling of RO membranes with a consequent reduction in flux rates and performance. Membrane bioreactors (MBR) have been shown to be highly effective in the removal of organic pollutants and suspended solids from tannery effluent. This research investigated the use of a combined MBR and RO treatment process to treat tannery effluents to an acceptable level for irrigation purposes. The MBR was operated at 17-20 h retention time, at a F/M ratio of 0.52 kg COD x kg SS(-1) x day(-1) and a volumetric loading rate of 3.28 kg COD x m(-3) x day(-1). This treatment reduced the COD, BOD, and ammonia concentrations of the effluent by 90-100%. The MBR was shown to be an excellent pretreatment prior to RO technology, due to the high removal efficiency of organic compounds and suspended solids, with average concentrations of 344 mg x L(-1) COD and 20 mg x L(-1) BOD achieved in the permeate. RO treatment reduced the salt content of the MBR permeate by up to 97.1%. The results of the research demonstrated that the MBR system developed was appropriate for the treatment of tannery effluents and, in combination with the RO treatment, reduced the salt content to acceptable levels for irrigation. The MBR pretreatment reduced bio-fouling and scaling of subsequent RO treatment and improved the overall performance of the RO unit. It is believed that this is the first investigation of a combined MBR and RO treatment for tannery effluents. This research provided data for an outline design of a full-scale MBR and RO plant with a treatment capacity of 5000 m3 per day for mixed tannery effluents.  相似文献   

4.
This study investigated possible biological control of membrane biofouling and membrane cleaning by disrupting energy metabolism of microorganisms. Results showed that 2,4-dinitrophenol (DNP), a typical uncoupler, could not only significantly inhibit membrane biofouling but also enhance biofilm detachment from nylon membrane. Inhibited ATP synthesis by a chemical uncoupler resulted in lowered production of autoinducer-2 (AI-2). The standard dead-end microfiltration tests further confirmed that the reduced AI-2 was positively correlated to the reduced fouling resistance of nylon membranes. It appears that inhibition of energy metabolism would be a promising alternative for control and cleaning of membrane biofouling.  相似文献   

5.
Fate of endocrine disrupting compounds in membrane bioreactor systems   总被引:2,自引:0,他引:2  
Yeast estrogen screen (YES) bioassay and liquid chromatography-mass spectrum-mass spectrum (LC-MS-MS) analysis were performed to investigate the fate of active and potential endocrine disrupting compounds in 3 pilot-scale and 2 lab-scale membrane bioreactor (MBR) systems. Compared with the overall estrogenicities of sewage treatment plant (STP) effluents from references, the MBR systems studied have relatively good performance in the removal of estrogenicity. Estrone (E1) was removed with relatively high efficiency (80.2-91.4%), but 17beta-estradiol (E2) was removed with moderate efficiency (49.3-66.5%) by the MBRs. However, the experimental results indicated that after the treatment by MBR, substantial amounts of E1, estrone-3-sulfate (E1-3S), estrone-3-glucuronide (E1-3G), and 17beta-estradiol-glucuronides (E2-G) passed through treatment systems and entered into the aquatic environment. The reduction in the levels of overall equivalent E1 (68.4%) and that of overall equivalent E2 (80.8%) was demonstrated for the pilot-scale MBR-B. For alkylphenol compounds, bisphenol A (BPA) was removed well with a removal efficiency of 68.9 -90.1%, but 4-nonylphenol (4-NP) concentration was amplified (removal efficiency of -439.5 to -161.1%) after MBR treatment which could be caused by the transformation of its parent compounds, nonylphenol polyethoxylates (NPnEOs). The amounts of adsorbed estrogens per kg dry mass was relatively low, due to short hydraulic retention time and high mixed liquor suspended solids in MBRs, compared to that in STPs.  相似文献   

6.
The interactions of mixed liquor fractions and their impacts on membrane fouling were examined at different sparging aeration intensities for submerged hollow-fiber membrane bioreactors (MBR) in wastewater treatment. The mixed liquor samples were fractioned by size into MLSS, colloids quantified by colloidal TOC, and dissolved solutes. The experimental results showed that their significance in membrane fouling was strongly related to aeration intensity. In the absence of sparging aeration, both MLSS and colloids contributed to membrane fouling which was further enhanced by their interactions. For the tested membrane module operated at the vigorous aeration intensity typically employed in practice, however, the deposition of colloids was identified as the most important mechanism controlling membrane fouling rates. In contrast, much fewer effects were exerted by MLSS: the overall fouling rates were increased initially, and then reduced with increasing concentration of MLSS. Thus, the aeration-induced turbulence should be considered for properly assessing the mixed liquor fouling potential for wastewater MBR processes. Finally, little difference in fouling rates was observed with the use of cyclic aeration mode as compared to continuous aeration mode.  相似文献   

7.
群体感应是细菌细胞与细胞之间的一种通讯机制,通过信号分子的不断积累,从而实现其特定基因的表达.群体感应淬灭可通过对信号分子的干扰和抑制,阻碍细菌群体感应进程,从而减缓特定食品的腐败速度,延长其货架期.因此,群体感应淬灭在食品保藏中的作用尤为重要.本文介绍了不同类型的群体感应系统及群体感应淬灭的机制,揭示了淬灭技术在食品...  相似文献   

8.
The elimination of six acidic pharmaceuticals (clofibric acid, diclofenac, ibuprofen, ketoprofen, mefenamic acid, and naproxen) in a real wastewater treatment plant (WWTP) using an activated sludge system and membrane bioreactors (MBRs) was investigated by using a gas chromatography/mass spectrometry (GC/MS) system for measurement of the compounds. Limited information is available for some of the tested pharmaceuticals at present. Solid retention times (SRTs) of the WWTP and the two MBRs were 7, 15, and 65 days, respectively. The elimination rates varied from compound to compound. The MBRs exhibited greater elimination rates for the examined pharmaceuticals than did the real plant. Dependency of the elimination rates of the pharmaceuticals on SRTs was obvious; the MBR operated with a longer SRT of 65 days clearly showed better performance than did the MBR with a shorter SRT of 15 days. The difference between the two MBRs was particularly significant in terms of elimination of ketoprofen and diclofenac. Measurements of the amounts of adsorbed pharmaceuticals on the sludge and aerobic batch elimination experiments were carried out to investigate the elimination pathways of the pharmaceuticals. Results of the batch elimination tests revealed that the sludges in the MBRs had large specific sorption capacities mainly due to their large specific surface areas. Despite the sorption capacities of sludges, the main mechanism of elimination of the pharmaceuticals in the investigated processes was found to be biodegradation. Biodegradation of diclofenac, which has been believed to be refractory to biodegradation, seemed to occur very slowly.  相似文献   

9.
We operated pilot-scale submerged membrane bioreactors (MBR) treating real municipal wastewater for over 3 months and observed an interesting phenomenon that carbohydrate concentrations in the MBRs rapidly increased, which consequently resulted in membrane fouling, when relative abundance of the member of uncultured Chloroflexi decreased from over 30% of total Bacteria to less than 10%. We, therefore, hypothesized that the uncultured Chloroflexi present in the MBRs could preferentially degrade carbohydrates and consequently prevent membrane fouling. To test this hypothesis, we investigated the phylogenetic identity, diversity, and in situ physiology (substrate utilization characteristics) of Chloroflexi residing in the MBR by using 16S rRNA gene sequencing analysis and microautoradiography combined with fluorescence in situ hybridization (MAR-FISH) technique. Most of the clones related to the phylum Chloroflexiwere affiliated with the Chloroflexi subphylum 1 containing only a few cultured representatives. The MAR-FISH revealed that the members of Chloroflexi were metabolically versatile and could preferentially utilize glucose and N-acetyl glucosamine (a main substantial constituent of the cell wall peptidoglycan) under oxic and anoxic conditions. The utilization of these compounds was low at low pH. These findings suggest that the members of Chloroflexi are ecologically significant in the MBR treating municipal wastewater and are responsible for degradation of SMP including carbohydrates and cellular materials, which consequently reduces membrane fouling potential.  相似文献   

10.
A pilot-scale membrane bioreactor (MBR) was installed and operated for one year at a Swiss hospital. It was fed an influent directly from the hospital's sanitary collection system. To study the efficiency of micropollutant elimination in raw hospital wastewater that comprises a complex matrix with micropollutant concentrations ranging from low ng/L to low mg/L, an automated online SPE-HPLC-MS/MS analytical method was developed. Among the 68 target analytes were the following: 56 pharmaceuticals (antibiotics, antimycotics, antivirals, iodinated X-ray contrast media, antiinflamatory, cytostatics, diuretics, beta blockers, anesthetics, analgesics, antiepileptics, antidepressants, and others), 10 metabolites, and 2 corrosion inhibitors. The MBR influent contained the majority of those target analytes. The micropollutant elimination efficiency was assessed through continuous flow-proportional sampling of the MBR influent and continuous time-proportional sampling of the MBR effluent. An overall load elimination of all pharmaceuticals and metabolites in the MBR was 22%, as over 80% of the load was due to persistent iodinated contrast media. No inhibition by antibacterial agents or disinfectants from the hospital was observed in the MBR. The hospital wastewater was found to be a dynamic system in which conjugates of pharmaceuticals deconjugate and biological transformation products are formed, which in some cases are pharmaceuticals themselves.  相似文献   