首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
    
In this study, we compare two evolving techniques for obtaining high‐resolution 3D anatomical data of a mouse specimen. On the one hand, we investigate cryotome‐based planar epi‐illumination imaging (cryo‐imaging). On the other hand, we examine X‐ray phase‐contrast micro‐computed tomography (micro‐CT) using synchrotron radiation. Cryo‐imaging is a technique in which an electron multiplying charge coupled camera takes images of a cryo‐frozen specimen during the sectioning process. Subsequent image alignment and virtual stacking result in volumetric data. X‐ray phase‐contrast imaging is based on the minute refraction of X‐rays inside the specimen and features higher soft‐tissue contrast than conventional, attenuation‐based micro‐CT. To explore the potential of both techniques for studying whole mouse disease models, one mouse specimen was imaged using both techniques. Obtained data are compared visually and quantitatively, specifically with regard to the visibility of fine anatomical details. Internal structure of the mouse specimen is visible in great detail with both techniques and the study shows in particular that soft‐tissue contrast is strongly enhanced in the X‐ray phase images compared to the attenuation‐based images. This identifies phase‐contrast micro‐CT as a powerful tool for the study of small animal disease models.  相似文献   

2.
Yang Y  Li W  Liu G  Zhang X  Chen J  Wu W  Guan Y  Xiong Y  Tian Y  Wu Z 《Journal of microscopy》2010,240(1):14-20
Cellular structures of the fission yeast, Schizosaccharomyces pombe, were examined by using hard X-ray tomography. Since cells are nearly transparent to hard X-rays, Zernike phase contrast and heavy metal staining were introduced to improve image contrast. Through using such methods, images taken at 8 keV displayed sufficient contrast for observing cellular structures. The cell wall, the intracellular organelles and the entire structural organization of the whole cells were visualized in three-dimensional at a resolution better than 100 nm. Comparison between phase contrast and absorption contrast was also made, indicating the obvious advantage of phase contrast for cellular imaging at this energy. Our results demonstrate that hard X-ray tomography with Zernike phase contrast is suitable for cellular imaging. Its unique abilities make it have potential to become a useful tool for revealing structural information from cells, especially thick eukaryotic cells.  相似文献   

3.
    
We present in this study results from X‐ray tomographic microscopy with synchrotron radiation performed both in attenuation and phase contrast modes on a limestone sample during two stages of water drying. No contrast agent was used in order to increase the X‐ray attenuation by water. We show that only by using the phase contrast mode it is possible to achieve enough water content change resolution to investigate the drying process at the pore‐scale. We performed 3D image analysis of the time‐differential phase contrast tomogram. We show by the results of such analysis that it is possible to obtain a reliable characterization of the spatial redistribution of water in the resolved pore system in agreement with what expected from the theory of drying in porous media and from measurements performed with other approaches. We thus show the potential of X‐ray phase contrast imaging for pore‐scale investigations of reactive water transport processes which cannot be imaged by adding a contrast agent for exploiting the standard attenuation contrast imaging mode.  相似文献   

4.
    
X‐ray computed tomography is a strong tool that finds many applications both in medical applications and in the investigation of biological and nonbiological samples. In the clinics, X‐ray tomography is widely used for diagnostic purposes whose three‐dimensional imaging in high resolution helps physicians to obtain detailed image of investigated regions. Researchers in biological sciences and engineering use X‐ray tomography because it is a nondestructive method to assess the structure of their samples. In both medical and biological applications, visualization of soft tissues and structures requires special treatment, in which special contrast agents are used. In this detailed report, molecule‐based and nanoparticle‐based contrast agents used in biological applications to enhance the image quality were compiled and reported. Special contrast agent applications and protocols to enhance the contrast for the biological applications and works to develop nanoparticle contrast agents to enhance the contrast for targeted drug delivery and general imaging applications were also assessed and listed.  相似文献   

5.
李达  倪晨  顾牡 《光学仪器》2009,31(5):24-27
实验室建立了以钨靶为光源的微聚焦X射线相衬成像系统,为减少应用过程中微聚焦光源的多色性对系统成像质量的影响,使用一系列不同厚度的铝质滤波片对弱吸收材料聚丙烯吸管进行微聚焦X射线相衬成像的研究。结果说明铝质滤波片能够改善成像质量,且随着铝质滤波片厚度的增加图像中物体的边缘特征的衬度呈指数衰减。为铝质滤波片在钨靶微聚焦X射线相衬成像系统中的应用提供了经验。  相似文献   

6.
    
In this study, we visualized the internal structures of various bio-samples and found the optimum conditions of test samples for the 7 keV hard X-ray microscope of the Pohang light source. From the captured X-ray images, we could observe the intercellular and intracellular structures of dehydrated human cells and mouse tumor tissues without using any staining materials in a spatial resolution better than 100 nm. The metastasized lung tissue, which was several tens of micrometers in thickness, was found to be very well suited to this hard X-ray microscope system, because it is nearly impossible to observe such a nontransparent and thick sample with a high spatial resolution better than 100 nm using any microscopes such as a soft X-ray microscope, an optical microscope, or an electron microscope.  相似文献   

7.
    
Onychomycosis, or fungal infection of the nail, is a disease seen frequently in clinical settings. However, the rates of positive identification using potassium hydroxide preparations or fungal cultures are relatively low. Precise diagnosis is possible via histopathologic examination to monitor the existence of fungus and performance of a fungal culture for confirmation. Phase-contrast hard X-ray microscopy using synchrotron radiation provides 70-nm spatial resolution and enables imaging of minute internal cellular structures. This study confirms the feasibility of diagnosing onychomycosis using a phase-contrast hard X-ray microscope developed at 1B2 beam line using a Pohang light source.  相似文献   

8.
    
We study the microstructure of a granular amorphous silica ceramic material synthesized by spark plasma sintering. Using monodisperse spherical silica particles as precursor, spark plasma sintering yields a dense granular material with distinct granule boundaries. We use selective etching to obtain nanoscopic pores along the granule borders. We interrogate this highly interesting material structure by combining scanning electron microscopy, X‐ray computed nanotomography and simulations based on random close packed spherical particles. We determine the degree of anisotropy caused by the uni‐axial force applied during sintering, and our analysis shows that our synthesis method provides a means to avoid significant granule growth and to fabricate a material with well‐controlled microstructure.  相似文献   

9.
    
X‐ray phase tomography aims at reconstructing the 3D electron density distribution of an object. It offers enhanced sensitivity compared to attenuation‐based X‐ray absorption tomography. In propagation‐based methods, phase contrast is achieved by letting the beam propagate after interaction with the object. The phase shift is then retrieved at each projection angle, and subsequently used in tomographic reconstruction to obtain the refractive index decrement distribution, which is proportional to the electron density. Accurate phase retrieval is achieved by combining images at different propagation distances. For reconstructions of good quality, the phase‐contrast images recorded at different distances need to be accurately aligned. In this work, we characterise the artefacts related to misalignment of the phase‐contrast images, and investigate the use of different registration algorithms for aligning in‐line phase‐contrast images. The characterisation of artefacts is done by a simulation study and comparison with experimental data. Loss in resolution due to vibrations is found to be comparable to attenuation‐based computed tomography. Further, it is shown that registration of phase‐contrast images is nontrivial due to the difference in contrast between the different images, and the often periodical artefacts present in the phase‐contrast images if multilayer X‐ray optics are used. To address this, we compared two registration algorithms for aligning phase‐contrast images acquired by magnified X‐ray nanotomography: one based on cross‐correlation and one based on mutual information. We found that the mutual information‐based registration algorithm was more robust than a correlation‐based method.  相似文献   

10.
    
Radiation beam interface contrast X‐ray microscopy provides resolution of a few dozen nanometers from fixed whole muscle biopsies, allowing better reconstruction of the microstructure of the muscle than is currently possible with classic histological techniques. Fixed soleus muscle biopsies have been evaluated from the walk‐in mouse model using phase‐contrast X‐ray microscopy, and results presented that corroborate the accuracy of the method used, and its potential for application in physiotherapy and occupational therapy studies. We believe that this method will enhance existing morphometric methods of analysis, leading to accurate reconstruction of other thick specimens that would otherwise require thin sectioning and reconstruction through deconvolution algorithms.  相似文献   

11.
    
Three‐dimensional (3D) printing technology has the advantage of enabling specific visualization of creative ideas. Since synchrotron based images can provide high sensitivity and high resolution, they are a very useful technology to identify the 3D anatomy of microscale samples. X‐ray images using such synchrotron radiation are grafted to 3D printing technology. We can be obtained 3D images and modeling data of an ant using synchrotron radiation, and then, it were outputted with the 3D printer. A new way to identify the usefulness of the structure analysis is then found by visualizing the micro‐internal structure of diverse biomedical samples and creating an enlarged model. This study suggests methods of utilizing a 3D printed model produced through synchrotron radiation imaging in various fields such as bioengineering, medical, and education.  相似文献   

12.
In this study, a new technique for three-dimensional imaging of biofilm within porous media using X-ray computed microtomography is presented. Due to the similarity in X-ray absorption coefficients for the porous media (plastic), biofilm and aqueous phase, an X-ray contrast agent is required to image biofilm within the experimental matrix using X-ray computed tomography. The presented technique utilizes a medical suspension of barium sulphate to differentiate between the aqueous phase and the biofilm. Potassium iodide is added to the suspension to aid in delineation between the biofilm and the experimental porous medium. The iodide readily diffuses into the biofilm while the barium sulphate suspension remains in the aqueous phase. This allows for effective differentiation of the three phases within the experimental systems utilized in this study. The behaviour of the two contrast agents, in particular of the barium sulphate, is addressed by comparing two-dimensional images of biofilm within a pore network obtained by (1) optical visualization and (2) X-ray absorption radiography. We show that the contrast mixture provides contrast between the biofilm, the aqueous-phase and the solid-phase (beads). The imaging method is then applied to two three-dimensional packed-bead columns within which biofilm was grown. Examples of reconstructed images are provided to illustrate the effectiveness of the method. Limitations and applications of the technique are discussed. A key benefit, associated with the presented method, is that it captures a substantial amount of information regarding the topology of the pore-scale transport processes. For example, the quantification of changes in porous media effective parameters, such as dispersion or permeability, induced by biofilm growth, is possible using specific upscaling techniques and numerical analysis. We emphasize that the results presented here serve as a first test of this novel approach; issues with accurate segmentation of the images, optimal concentrations of contrast agents and the potential need for use of synchrotron radiation sources need to be addressed before the method can be used for precise quantitative analysis of biofilm geometry in porous media.  相似文献   

13.
We used hard X-ray scanning microscopy with ptychographic coherent diffraction contrast to image a front-end processed passivated microchip fabricated in 80 nm technology. No sample preparation was needed to image buried interconnects and contact layers with a spatial resolution of slightly better than 40 nm. The phase shift in the sample is obtained quantitatively. With the additional knowledge of the elemental composition determined in parallel by X-ray fluorescence mapping, quantitative information about specific nanostructures is obtained. A significant enhancement in signal-to-noise ratio and spatial resolution is achieved compared to conventional hard X-ray scanning microscopy.  相似文献   

14.
    
We explore the effect of noise on images obtained using quantitative phase‐amplitude microscopy – a new microscopy technique based on the determination of phase from the intensity evolution of propagating radiation. We compare the predictions with experimental results and also propose an approach that allows good‐quality quantitative phase retrieval to be obtained even for very noisy data.  相似文献   

15.
    
The science of wave‐field phase retrieval and phase measurement is sufficiently mature to permit the routine reconstruction, over a given plane, of the complex wave‐function associated with certain coherent forward‐propagating scalar wave‐fields. This reconstruction gives total knowledge of the information that has been encoded in the complex wave‐field by passage through a sample of interest. Such total knowledge is powerful, because it permits the emulation in software of the subsequent action of an infinite variety of coherent imaging systems. Such ‘virtual optics’, in which software forms a natural extension of the ‘hardware optics’ in an imaging system, may be useful in contexts such as quantitative atom and X‐ray imaging, in which optical elements such as beam‐splitters and lenses can be realized in software rather than optical hardware. Here, we develop the requisite theory to describe such hybrid virtual‐physical imaging systems, which we term ‘omni optics’ because of their infinite flexibility. We then give an experimental demonstration of these ideas by showing that a lensless X‐ray point projection microscope can, when equipped with the appropriate software, emulate an infinite variety of optical imaging systems including those which yield interferograms, Zernike phase contrast, Schlieren imaging and diffraction‐enhanced imaging.  相似文献   

16.
  总被引:3,自引:0,他引:3  
We demonstrate simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object. Subject to the assumptions explicitly stated in the derivation, the algorithm solves the twin‐image problem of in‐line holography and is capable of analysing data obtained using X‐ray microscopy, electron microscopy, neutron microscopy or visible‐light microscopy, especially as they relate to defocus and point projection methods. Our simple, robust, non‐iterative and computationally efficient method is applied to data obtained using an X‐ray phase contrast ultramicroscope.  相似文献   

17.
The influence of different physical parameters, such as the source size and the energy spectrum, on the functional capability of a grating interferometer applied for phase‐contrast imaging is discussed using numerical simulations based on Fresnel diffraction theory. The presented simulation results explain why the interferometer could be well combined with polychromatic laboratory x‐ray sources in recent experiments. Furthermore, it is shown that the distance between the two gratings of the interferometer is not in general limited by the width of the photon energy spectrum. This implies that interferometers that give a further improved image quality for phase measurements can be designed, because the primary measurement signal for phase measurements can be increased by enlargement of this distance. Finally, the mathematical background and practical instructions for the quantitative evaluation of measurement data acquired with a polychromatic x‐ray source are given.  相似文献   

18.
    
High contrast imaging of in vivo Chlorella sorokiniana cells with submicron spatial resolution was obtained with a contact water window X-ray microscopy technique using a point-like, laser-plasma produced, water-window X-ray radiation source, and LiF crystals as detectors. This novel type of X-ray imaging detectors is based on photoluminescence of stable electronic point defects, characterized by high intrinsic resolution. The fluorescence images obtained on LiF crystals exposed in single-shot experiments demonstrate the high sensitivity and dynamic range of this new detector. The powerful performances of LiF crystals allowed us to detect the exudates of Chlorella cells in their living medium and their spatial distribution in situ, without any special sample preparation.  相似文献   

19.
    
Mimosa pudica has three distinct specialized organs, namely, pulvinus, secondary pulvinus, and pulvinule, which are respectively controlling the movements of petioles, leaflets, and pinna in response to external stimuli. Water flow is a key factor for such movements, but detailed studies on the organization of the vascular system for water transport in these organs have not been published yet. In this study, organizations of the xylem vessels and morphological features of the pulvinus, the secondary pulvinus, and the pulvinule were experimentally investigated by X‐ray computed tomography and histological technique. Results showed that the xylem vessels were circularly distributed in the specialized motile organs and reorganized into distinct vascular bundles at the extremities. The number and the total cross‐sectional area of the xylem vessels were increased inside the specialized motile organs. Morphological characteristics obtained in this study provided new insight to understand the functions of the vascular networks in the dynamic movements of M. pudica. Microsc. Res. Tech. 76:1204–1212, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

20.
    
The torsion distribution of cell paths in two‐phase flow of a cell suspension through a porous medium is an important quantity for chromatographic processes. It can be estimated from cell tracking in sequences of three‐dimensional images of a suspension pumped through the medium, where the images are acquired by in‐situ time‐resolved microtomography using synchrotron radiation and inline phase contrast modus. This contribution presents a new method for estimating path torsion from discrete positions, where the estimation is based on an appropriate discretization of the differential‐geometric formula of the torsion of a space curve. Investigations performed for an alcoholic suspension of silica gel particles pumped through a partially open polyurethane foam show that the shape of the inner surface of the foam has a considerable impact on the particle paths. It turns out that the variance of the torsion for slow particle moving close to the surface is a half order of magnitude smaller than that of fast particles, which underlines the importance of torsion for filter efficiency.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号