首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, we compare two evolving techniques for obtaining high‐resolution 3D anatomical data of a mouse specimen. On the one hand, we investigate cryotome‐based planar epi‐illumination imaging (cryo‐imaging). On the other hand, we examine X‐ray phase‐contrast micro‐computed tomography (micro‐CT) using synchrotron radiation. Cryo‐imaging is a technique in which an electron multiplying charge coupled camera takes images of a cryo‐frozen specimen during the sectioning process. Subsequent image alignment and virtual stacking result in volumetric data. X‐ray phase‐contrast imaging is based on the minute refraction of X‐rays inside the specimen and features higher soft‐tissue contrast than conventional, attenuation‐based micro‐CT. To explore the potential of both techniques for studying whole mouse disease models, one mouse specimen was imaged using both techniques. Obtained data are compared visually and quantitatively, specifically with regard to the visibility of fine anatomical details. Internal structure of the mouse specimen is visible in great detail with both techniques and the study shows in particular that soft‐tissue contrast is strongly enhanced in the X‐ray phase images compared to the attenuation‐based images. This identifies phase‐contrast micro‐CT as a powerful tool for the study of small animal disease models.  相似文献   

2.
X‐ray phase tomography aims at reconstructing the 3D electron density distribution of an object. It offers enhanced sensitivity compared to attenuation‐based X‐ray absorption tomography. In propagation‐based methods, phase contrast is achieved by letting the beam propagate after interaction with the object. The phase shift is then retrieved at each projection angle, and subsequently used in tomographic reconstruction to obtain the refractive index decrement distribution, which is proportional to the electron density. Accurate phase retrieval is achieved by combining images at different propagation distances. For reconstructions of good quality, the phase‐contrast images recorded at different distances need to be accurately aligned. In this work, we characterise the artefacts related to misalignment of the phase‐contrast images, and investigate the use of different registration algorithms for aligning in‐line phase‐contrast images. The characterisation of artefacts is done by a simulation study and comparison with experimental data. Loss in resolution due to vibrations is found to be comparable to attenuation‐based computed tomography. Further, it is shown that registration of phase‐contrast images is nontrivial due to the difference in contrast between the different images, and the often periodical artefacts present in the phase‐contrast images if multilayer X‐ray optics are used. To address this, we compared two registration algorithms for aligning phase‐contrast images acquired by magnified X‐ray nanotomography: one based on cross‐correlation and one based on mutual information. We found that the mutual information‐based registration algorithm was more robust than a correlation‐based method.  相似文献   

3.
We present in this study results from X‐ray tomographic microscopy with synchrotron radiation performed both in attenuation and phase contrast modes on a limestone sample during two stages of water drying. No contrast agent was used in order to increase the X‐ray attenuation by water. We show that only by using the phase contrast mode it is possible to achieve enough water content change resolution to investigate the drying process at the pore‐scale. We performed 3D image analysis of the time‐differential phase contrast tomogram. We show by the results of such analysis that it is possible to obtain a reliable characterization of the spatial redistribution of water in the resolved pore system in agreement with what expected from the theory of drying in porous media and from measurements performed with other approaches. We thus show the potential of X‐ray phase contrast imaging for pore‐scale investigations of reactive water transport processes which cannot be imaged by adding a contrast agent for exploiting the standard attenuation contrast imaging mode.  相似文献   

4.
We developed cryo‐scanning x‐ray diffraction microscopy, utilizing hard x‐ray ptychography at cryogenic temperature, for the noninvasive, high‐resolution imaging of wet, extended biological samples and report its first frozen‐hydrated imaging. Utilizing phase contrast at hard x‐rays, cryo‐scanning x‐ray diffraction microscopy provides the penetration power suitable for thick samples while retaining sensitivity to minute density changes within unstained samples. It is dose‐efficient and further minimizes radiation damage by keeping the wet samples at cryogenic temperature. We demonstrate these capabilities in two dimensions by imaging unstained frozen‐hydrated budding yeast cells, achieving a spatial resolution of 85 nm with a phase sensitivity of 0.0053 radians. The current work presents the feasibility of cryo‐scanning x‐ray diffraction microscopy for quantitative, high‐resolution imaging of unmodified biological samples extending to tens of micrometres.  相似文献   

5.
In this paper, the use of lithium fluoride (LiF) as imaging radiation detector to analyse living cells by single‐shot soft X‐ray contact microscopy is presented. High resolved X‐ray images on LiF of cyanobacterium Leptolyngbya VRUC135, two unicellular microalgae of the genus Chlamydomonas and mouse macrophage cells (line RAW 264.7) have been obtained utilizing X‐ray radiation in the water window energy range from a laser plasma source. The used method is based on loading of the samples, the cell suspension, in a special holder where they are in close contact with a LiF crystal solid‐state X‐ray imaging detector. After exposure and sample removal, the images stored in LiF by the soft X‐ray contact microscopy technique are read by an optical microscope in fluorescence mode. The clear image of the mucilaginous sheath the structure of the filamentous Leptolyngbya and the visible nucleolus in the macrophage cells image, are noteworthiness results. The peculiarities of the used X‐ray radiation and of the LiF imaging detector allow obtaining images in absorption contrast revealing the internal structures of the investigated samples at high spatial resolution. Moreover, the wide dynamic range of the LiF imaging detector contributes to obtain high‐quality images. In particular, we demonstrate that this peculiar characteristic of LiF detector allows enhancing the contrast and reveal details even when they were obscured by a nonuniform stray light.  相似文献   

6.
X‐ray computed tomography is a strong tool that finds many applications both in medical applications and in the investigation of biological and nonbiological samples. In the clinics, X‐ray tomography is widely used for diagnostic purposes whose three‐dimensional imaging in high resolution helps physicians to obtain detailed image of investigated regions. Researchers in biological sciences and engineering use X‐ray tomography because it is a nondestructive method to assess the structure of their samples. In both medical and biological applications, visualization of soft tissues and structures requires special treatment, in which special contrast agents are used. In this detailed report, molecule‐based and nanoparticle‐based contrast agents used in biological applications to enhance the image quality were compiled and reported. Special contrast agent applications and protocols to enhance the contrast for the biological applications and works to develop nanoparticle contrast agents to enhance the contrast for targeted drug delivery and general imaging applications were also assessed and listed.  相似文献   

7.
Radiation beam interface contrast X‐ray microscopy provides resolution of a few dozen nanometers from fixed whole muscle biopsies, allowing better reconstruction of the microstructure of the muscle than is currently possible with classic histological techniques. Fixed soleus muscle biopsies have been evaluated from the walk‐in mouse model using phase‐contrast X‐ray microscopy, and results presented that corroborate the accuracy of the method used, and its potential for application in physiotherapy and occupational therapy studies. We believe that this method will enhance existing morphometric methods of analysis, leading to accurate reconstruction of other thick specimens that would otherwise require thin sectioning and reconstruction through deconvolution algorithms.  相似文献   

8.
Three‐dimensional (3D) printing technology has the advantage of enabling specific visualization of creative ideas. Since synchrotron based images can provide high sensitivity and high resolution, they are a very useful technology to identify the 3D anatomy of microscale samples. X‐ray images using such synchrotron radiation are grafted to 3D printing technology. We can be obtained 3D images and modeling data of an ant using synchrotron radiation, and then, it were outputted with the 3D printer. A new way to identify the usefulness of the structure analysis is then found by visualizing the micro‐internal structure of diverse biomedical samples and creating an enlarged model. This study suggests methods of utilizing a 3D printed model produced through synchrotron radiation imaging in various fields such as bioengineering, medical, and education.  相似文献   

9.
This article addresses an important current development in medical and biological imaging: the possibility of imaging soft tissue at resolutions in the micron range using hard X‐rays. Challenging environments, including the cochlea, require the imaging of soft tissue structure surrounded by bone. We demonstrate that cochlear soft tissue structures can be imaged with hard X‐ray phase contrast. Furthermore, we show that only a thin slice of the tissue is required to introduce a large phase shift. It is likely that the phase contrast image of the soft tissue structures is sufficient to image the structures even if surrounded by bone. For the present set of experiments, structures with low‐absorption contrast have been visualized using in‐line phase contrast imaging and a grating interferometer. The experiments have been performed at the Advanced Photon Source at Argonne National Laboratories, a third generation source of synchrotron radiation. The source provides highly coherent X‐ray radiation with high‐photon flux (>1012 photons/s) at high‐photon energies (5–70 keV). Radiographic and light microscopy images of the gerbil cochlear slice samples were compared. It has been determined that a 20‐μm thick tissue slice induces a phase shift between 1/3π and 2/3π. Microsc. Res. Tech., 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

10.
We set out to study connected porosity of crystalline rock using X‐ray microtomography and scanning electron microscopy with energy dispersive X‐ray spectroscopy (SEM‐EDS) with caesium chloride as a contrast agent. Caesium is an important radionuclide regarding the final deposition of nuclear waste and also forms dense phases that can be readily distinguished by X‐ray microtomography and SEM‐EDS. Six samples from two sites, Olkiluoto (Finland) and Grimsel (Switzerland), where transport properties of crystalline rock are being studied in situ, were investigated using X‐ray microtomography and SEM‐EDS. The samples were imaged with X‐ray microtomography, immersed in a saturated caesium chloride (CsCl) solution for 141, 249 and 365 days and imaged again with X‐ray microtomography. CsCl inside the samples was successfully detected with X‐ray microtomography and it had completely penetrated all six samples. SEM‐EDS elemental mapping was used to study the location of caesium in the samples in detail with quantitative mineral information. Precipitated CsCl was found in the connected pore space in Olkiluoto veined gneiss and in lesser amounts in Grimsel granodiorite. Only a very small amount of precipitated CsCl was observed in the Grimsel granodiorite samples. In Olkiluoto veined gneiss caesium was found in pinitised areas of cordierite grains. In the pinitised areas caesium was found in notable excess compared to chloride, possibly due to the combination of small pore size and negatively charged surfaces. In addition, elevated concentrations of caesium were found in kaolinite and sphalerite phases. The findings concerning the location of CsCl were congruent with X‐ray microtomography.  相似文献   

11.
High‐resolution tomographic images using synchrotron X‐rays are expected to provide detailed reflection of microstructures, thereby allowing for the examination of histologic structures without destruction of the specimen. This study aims to evaluate the synchrotron tomographic images of mixed ground‐glass opacity excised on 5‐mm sections in comparison to pathologic examination. The Institutional Review Board of our institute approved this retrospective study, and written informed consent was obtained from each patient whose lung tissue would be used. Obtained lung cancer specimens were brought to the multiple Wiggler 6C beam line at the Pohang Light Source (PLS‐II) in Korea, and phase contrast X‐ray images were obtained in November 2016. The X‐ray emanated from a bending magnet of the electron storage ring with electron energy of 3 GeV, and a typical beam current was 320 mA. Reconstructed tomographic images were compared with images from histologic slides obtained from the same samples. Pulmonary microstructures including terminal bronchioles, alveolar sacs, and vasculature were identified with phase contrast X‐ray images. Images from normal lung tissue and mixed ground‐glass opacity were clearly distinguishable. Hyperplasia of the interalveolar septum and dysplasia of microstructure were clearly identified. The imaging findings correlated well with hematoxylin‐eosin stained specimens. Tomographic images using synchrotron radiation have the potential for clinical applications. With refinement, this technique may become a diagnostic tool for detection of lung cancer.  相似文献   

12.
The retina is one of the most tiny and sophisticated tissues of the body. Three dimensional (3D) visualization of the whole retina is valuable both in clinical and research arenas. The tissue has been predominantly assessed by time‐consuming histopathology and optical coherence tomography (OCT) in research and clinical arenas. However, none of the two methods can provide 3D imaging of the retina. The purpose of this study is to give a volumetric visualization of rat retina at submicron resolution, using an emerging imaging technique‐phase‐contrast X‐ray CT. A Sprague‐Dawley (SD) rat eye specimen was scanned with X‐ray differential phase contrast tomographic microscopy (DPC‐microCT) equipped at the Swiss Light Source synchrotron. After scanning, the specimen was subjected to routine histology procedures and severed as a reference. The morphological characteristics and signal features of the retina in the DPC‐microCT images were evaluated. The total retina and its sublayers thicknesses were measured on the DPC‐microCT images and compared with those obtained from the histological sections. The retina structures revealed by DPC‐microCT were highly consistent with the histological section. In this study, we achieved nondestructive 3D visualization of SD rat retina. In addition to detailed anatomical structures, the objective parameters provided by DPC‐microCT make it a useful tool for retinal research and disease diagnosis in the early stage.  相似文献   

13.
A robust and versatile sample preparation technique for the fabrication of cylindrical pillars for imaging by X‐ray nano‐computed tomography (nano‐CT) is presented. The procedure employs simple, cost‐effective laser micro‐machining coupled with focused‐ion beam (FIB) milling, when required, to yield mechanically robust samples at the micrometre length‐scale to match the field‐of‐view (FOV) for nano‐CT imaging. A variety of energy and geological materials are exhibited as case studies, demonstrating the procedure can be applied to a variety of materials to provide geometrically optimised samples whose size and shape are tailored to the attenuation coefficients of the constituent phases. The procedure can be implemented for the bespoke preparation of pillars for both lab‐ and synchrotron‐based X‐ray nano‐CT investigations of a wide range of samples.  相似文献   

14.
The soft X‐ray microscope at the Lawrence Berkeley National Laboratory was developed for visualization of biological tissue. Soft X‐ray microscopy provides high‐resolution visualization of hydrated, non‐embedded and non‐sectioned cells and is thus potentially an alternative to transmission electron microscopy. Here we show for the first time soft X‐ray micrographs of structures isolated from the guinea‐pig inner ear. Sensory outer hair cells and supporting pillar cells are readily visualized. In the hair cells, individual stereocilia can easily be identified within the apical hair bundle. The underlying cuticular plate is, however, too densely composed or too thick to be clearly visualized, and thus appears very dark. The cytoplasmic structures protruding from the cuticular plates as well as the fibrillar material surrounding and projecting from the cell nuclei can be seen. In the pillar cells the images reveal individual microtubule bundles. Soft X‐ray images of the acellular tectorial membrane and thin two‐layered Reissner's membrane display a level of resolution comparable to low‐power electron microscopy.  相似文献   

15.
High resolution X‐ray computed tomography (CT), or microCT, is a promising and already widely used technique in various scientific fields. Also for histological purposes it has great potential. Although microCT has proven to be a valuable technique for the imaging of bone structures, the visualization of soft tissue structures is still an important challenge due to their low inherent X‐ray contrast. One way to achieve contrast enhancement is to make use of contrast agents. However, contrary to light and electron microscopy, knowledge about contrast agents and staining procedures is limited for X‐ray CT. The purpose of this paper is to identify useful X‐ray contrast agents for soft tissue visualization, which can be applied in a simple way and are also suited for samples larger than (1 cm)3. And 28 chemical substances have been investigated. All chemicals were applied in the form of concentrated aqueous solutions in which the samples were immersed. First, strips of green Bacon were stained to evaluate contrast enhancement between muscle and adipose tissue. Furthermore it was also tested whether the contrast agents remained fixed in the tissue after staining by re‐immersing them in water. Based on the results, 12 contrast agents were selected for further testing on postmortem mice hind legs, containing a variety of different tissues, including muscle, fat, bone, cartilage and tendons. It was evaluated whether the contrast agents allowed a clearer distinction between the different soft tissue structures present. Finally also penetration depth was measured. And 26 chemicals resulted in contrast enhancement between muscle and adipose tissue in the Bacon strips. Mercury(II)chloride (HgCl2), phosphotungstic acid (PTA), phosphomolybdic acid (PMA) and ammonium orthomolybdate ((NH4)2MoO4) remained fixed after re‐immersion in water. The penetration tests showed that potassium iodide (KI) and sodium tungstate can be most efficiently used for large samples of the order of several tens of cm3. PMA, PTA, HgCl2 and also to a lesser extent Na2WO4 and (NH4)2MoO4 allowed a clearer distinction between the different soft tissue structures present.  相似文献   

16.
X-ray high-resolution vascular network imaging   总被引:3,自引:1,他引:3  
This paper presents the first application of high‐resolution X‐ray synchrotron tomography to the imaging of large microvascular networks in biological tissue samples. This technique offers the opportunity of analysing the full three‐dimensional vascular network from the micrometre to the millimetre scale. This paper presents the specific sample preparation method and the X‐ray imaging procedure. Either barium or iron was injected as contrast agent in the vascular network. The impact of the composition and concentration of the injected solution on the X‐ray synchrotron tomography images has been studied. Two imaging modes, attenuation and phase contrast, are compared. Synchrotron high‐resolution computed tomography offers new prospects in the three‐dimensional imaging of in situ biological vascular networks.  相似文献   

17.
Nanoscopic synchrotron X‐ray imaging was performed on scalp hair samples of patients with breast cancer and healthy individuals to investigate any structural differences as diagnostic tool. Hair strands were divided into 2‐3 segments along the strands from root to tip, followed by imaging either in projection or in CT scanning with a monochromatic 6.78‐keV X‐ray using zone‐plate optics with a resolving power of 60 nm. All the examined cancer hairs exhibited medulla loss with cancer stage‐dependent pattern; complete loss, discontinuous or trace along the strands. In contrast, medullas were well retained without complete loss in the healthy hair. In the CT‐scanned axial images, the cortical spindle compartments had no contrast in the healthy hair, but appeared hypointense in contrast to the surrounding hyperintense cortical membrane complex in the cancer hair. In conclusion, observation of medulla loss and cortical membrane enhancements in the hair strands of breast cancer patients demonstrated structural variations in the cancer hair, providing a new platform for further synchrotron X‐ray imaging study of screening breast cancer patients. Microsc. Res. Tech. 79:23–30, 2016. © 2015 Wiley Periodicals, Inc.  相似文献   

18.
Aberration‐corrected scanning transmission electron microscopes are able to form electron beams smaller than 100 pm, which is about half the size of an average atom. Probing materials with such beams leads to atomic‐resolution images, electron energy loss and energy‐dispersive X‐ray spectra obtained from single atomic columns and even single atoms, and atomic‐resolution elemental maps. We review briefly how such electron beams came about, and show examples of applications. We also summarize recent developments that are propelling aberration‐corrected scanning transmission electron microscopes in new directions, such as complete control of geometric aberration up to fifth order, and ultra‐high‐energy resolution EELS that is allowing vibrational spectroscopy to be carried out in the electron microscope.  相似文献   

19.
The influence of different physical parameters, such as the source size and the energy spectrum, on the functional capability of a grating interferometer applied for phase‐contrast imaging is discussed using numerical simulations based on Fresnel diffraction theory. The presented simulation results explain why the interferometer could be well combined with polychromatic laboratory x‐ray sources in recent experiments. Furthermore, it is shown that the distance between the two gratings of the interferometer is not in general limited by the width of the photon energy spectrum. This implies that interferometers that give a further improved image quality for phase measurements can be designed, because the primary measurement signal for phase measurements can be increased by enlargement of this distance. Finally, the mathematical background and practical instructions for the quantitative evaluation of measurement data acquired with a polychromatic x‐ray source are given.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号