首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
The temperature dependence of the solid particle erosion of polydimethylsiloxane (PDMS) using aluminum oxide particles was investigated between the temperatures of ?178 and 17 °C for a variety of angles of attack using a novel cryogenic abrasive jet machining apparatus. It was found that the most efficient machining of PDMS (volume removed per kinetic energy of erodent) occurred at approximately ?178 °C, at angles of attack between 30° and 60° from the surface. A previously developed surface evolution model was used to predict the size and shape of unmasked channels at various temperatures. A good agreement between the predicted and measured channel profiles was obtained when the average blasting temperature was between approximately ?127 and ?178 °C. At ?82 °C, the fit was poorer, probably because of an increase in particle embedding. Although it was demonstrated that PDMS could be machined at temperatures above its glass transition, the erosion rate increased by a factor of more than 10 when the machining temperature was below this point.  相似文献   

2.
This paper presents the design and calibration of an ISO non-compliant orifice plate flowmeter whose intended use is for respiratory function measurements in the bidirectional air flow range ±9 L/min.The novelty of the proposed sensor consists of a plate beveled in both upstream and downstream sides: a symmetrical geometry is adopted in order to perform bidirectional measurements of flow rate. A mathematical model is introduced to quantify the influence of temperature on the sensor output. Four different positions of the pressure static taps are evaluated in order to maximize bidirectionality. An index is also introduced in order to quantitatively estimate the anti-symmetry of the sensor's response curve.Trials are carried out to evaluate the influence on sensor output of air temperatures (22 °C, 30 °C and 37 °C) at different values of relative humidity (5%, 55% and 85%). Experimental data show a quite good agreement with the theoretical model (R2>0.98 in each condition).The influence of air temperature on the sensor output is minimized by introducing a correction factor based on the theoretical model leading to measurement repeatability better than 2% in overall range of calibration. The mean sensitivity in the calibration range is about 2 kPa L−1·min allowing to obtain a sensor discrimination threshold lower than 0.2 L/min in both directions. The time constant of the whole measurement system, equal to 2.40±0.03 ms, leads to a bandwidth up to 80 Hz making the sensor suitable for respiratory function measurements.  相似文献   

3.
《Wear》2006,260(9-10):919-932
The variation in wear behaviour during limited debris retention sliding wear of Nimonic 80A versus Stellite 6 (counterface) between room temperature and 750 °C, at sliding speeds of 0.314, 0.654 and 0.905 m s−1, was investigated. At 0.314 m s−1, mild oxidational wear was observed at all temperatures, due to transfer and oxidation of Stellite 6-sourced debris to the Nimonic 80A and resultant separation of the Nimonic 80A and Stellite 6 wear surfaces. Between room temperature and 450 °C, this debris mostly remained in the form of loose particles (with only limited compaction), whilst between 510 and 750 °C, the particles were compacted and sintered together to form a wear protective ‘glaze’ layer.At 0.654 and 0.905 m s−1, mild oxidational wear due to transfer and oxidation of Stellite 6-sourced debris was only observed at room temperature and 270 °C (also 390 °C at 0.654 m s−1). At 390 °C (450 °C at 0.654 m s−1) and above, this oxide was completely absent and ‘metal-to-metal’ contact resulted in an intermediate temperature severe wear regime—losses in the form of ejected metallic debris were sourced almost completely from the Nimonic 80A. Oxide debris, this time sourced from the Nimonic 80A sample, did not reappear until 570 °C (630 °C at 0.654 m s−1), however, were insufficient to eliminate completely severe wear until 690 and 750 °C. At both 0.654 and 0.905 m s−1, the oxide now preventing severe wear at 690 and 750 °C tended not to form ‘glaze’ layers on the surface of the Nimonic 80A and instead supported continued high wear by abrasion. This abrasive action was attributed to the poor sintering characteristics of the Nimonic 80A-sourced oxide, in combination with the oxides’ increased mobility and decreased residency.The collected data were used to compose a simple wear map detailing the effects of sliding speed and temperature on the wear of Nimonic 80A slid against Stellite 6, at these speeds and temperatures of between room temperature and 750 °C.  相似文献   

4.
《Wear》2006,260(1-2):40-49
The tribological behaviour of TiCN coating prepared by unbalanced magnetron sputtering is studied in this work. The substrates made from austenitic steel were coated by TiCN coatings during one deposition. The measurements were provided by high temperature tribometer (pin-on-disc, CSM Instruments) allowing measuring the dependency of friction coefficient on cycles (sliding distance) up to 500 °C. The evolution of the friction coefficient with the cycles was measured under different conditions, such as temperature or sliding speed and the wear rate of the ball and coating were evaluated. The 100Cr6 balls and the Si3N4 ceramic balls were used as counter-parts. The former were used at temperatures up to 200 °C, the latter up to 500 °C. The wear tracks were examined by optical methods and SEM. The surface oxidation at elevated temperatures and profile elements composition of the wear track were also measured.The experiments have shown considerable dependency of TiCN tribological parameters on temperature. Rise in temperature increased both friction coefficient and the wear rate of the coating in case of 100Cr6 balls. The main wear mechanism was a mild wear at temperatures up to 200 °C; fracture and delamination were dominating wear mechanisms at temperatures from 300 to 500 °C.  相似文献   

5.
We propose a non-contact temperature measurement method that combines the temperature dependence of transmittance below 600 °C and radiation thermometry above 600 °C. The combined method uses a polarization technique and the Brewster angle between air and a dielectric film such as SiO2 or Si3N4 grown on silicon wafers. A prominent feature of this method is that both measurements of transmittance and radiance are performed with the same geometrical arrangement.For a semitransparent wafer, the measurement of p-polarized transmittance at the wavelengths of 1.1, 1.2 and 1.3 μm enables temperature measurement in the range from room temperature to 600 °C. For an opaque wafer above 600 °C, the p-polarized radiation thermometry at the wavelength of 4.5 μm allows the temperature measurement without the emissivity problem. The combined method with the use of transmittance and radiance is valid in the entire temperature range irrespective of variations of film thickness and resistivity.  相似文献   

6.
The tribological properties of Ni-17.5Si-29.3Cr alloy against Si3N4 were studied on a ball-on-disc tribotester between room temperature and 1000 °C. The effects of temperature on the tribological properties of the alloy were investigated. The worn surfaces of the alloy were examined using scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The results indicated that the tribological behavior of the alloy expressed some differences with increase in testing temperature. At low and moderate temperatures (below 800 °C), the alloy showed excellent wear and oxidation resistances, and the wear rate of the alloy remained in the magnitude of 10?5 mm3/Nm; but at elevated temperature (800–1000 °C), the wear and oxidation resistances decreased, and the wear rate of the alloy increased up to 10?4 mm3/Nm. The friction coefficient decreased from 0.58 to 0.46 with the rising of testing temperature from 20 to 600 °C, and then remained nearly constant. The wear mechanism of the alloy was mainly fracture and delamination at low and moderate temperatures, and transformed to adhesive and oxidation at elevated temperatures.  相似文献   

7.
A portable device for calibration of trace humidity sensors and an adopted calibration procedure have been developed. The calibration device is based on humidity generation by permeating water through polymeric membrane tubes. Water vapour transmission rates for various polymers were experimentally determined in order to select the most suitable polymeric material. The developed trace humidity generator consists of a gas-flow polymeric hose immersed in a water reservoir thermostated by a sensor-controlled heater. Mole fractions of water vapour between 1 μmol mol−1 and 350 μmol mol−1 (equivalent to frost-point temperatures from −76 °C to −31 °C) were generated by varying either the operating temperature or gas flow. The operating temperature can be varied from 20 °C to 60 °C and kept stable within 0.1 K. Uncertainty analysis indicated that the trace humidity generator produces gas flows of constant humidity amounts with a relative expanded uncertainty less than 3.4% (k = 2) of the generated value.  相似文献   

8.
Fretting of AISI 301 stainless steel sheet in contact with AISI 52100 steel from 20 °C to 550 °C in air and argon has been studied. Transitions in the mechanical properties of 301SS and oxidative behavior of this pair have been identified as a function of temperature. Strength and ductility of 301SS is reduced from 20 °C to 250 °C, increasing susceptibility to fretting damage. Steady state friction decreases as temperature increases, reducing cyclic stresses. Wear resistance increases in this temperature range, increasing fatigue damage due to the increase in fatigue life associated with increased wear. This study aims to identify the causes of the transitions in behavior and determine the net outcome of the competing effects with regard to fatigue damage.  相似文献   

9.
Cu films were deposited on Si substrates by direct current (DC) magnetron sputtering at three different substrate temperatures such as room temperature (RT), 100 °C and 200 °C. Possible mechanisms for substrate temperature dependent microstructure evolution in Cu films are discussed in this paper. Enhanced mechanical properties such as high hardness, high elastic modulus, low friction coefficient and high wear resistance of the films were obtained at deposition temperature of 100 °C. However, high friction coefficient as well as high wear rate was measured in films deposited at room temperature and 200 °C.  相似文献   

10.
T. Polcar  M. Evaristo  M. Stueber  A. Cavaleiro 《Wear》2009,266(3-4):393-397
Transition metal dichalcogenides belong to the more developed class of materials for solid lubrication. However, the main limitation of these materials is the detrimental effect of air humidity causing an increase in the friction. In previous works, molybdenum diselenide has been shown to be a promising coating retaining low friction even in very humid environment. In this study, Mo–Se–C films were deposited by sputtering from a C target with pellets of MoSe2. Besides the evaluation of the chemical composition, the structure, the morphology, the hardness and the cohesion/adhesion, special attention was paid to the tribological characterization.The C content varied from 29 to 68 at.% which led to a progressive increase of the Se/Mo ratio. As a typical trend, the hardness increases with increasing C content. The coatings were tested at room temperature with different air humidity levels and at temperatures up to 500 °C on a pin-on-disc tribometer. The friction coefficient of Mo–Se–C coatings increased with air humidity from ~0.04 to ~0.12, while it was as low as 0.02 at temperature range 100–250 °C. The coatings were very sensitive to the elevated temperature being worn out at 300 °C due to adhesion problems at coating–titanium interface.  相似文献   

11.
Incomplete mixing of fluids of different temperatures generates thermal striping, which is to date difficult to accurately predict. For metal piping the induced temperature fluctuations are harmful, because they lead to thermal fatigue. This phenomenon is significant in nuclear power plant safety considerations, in particular in connection with aging of the equipment. This work contributes to the current research effort by presenting an array of resistive temperature detectors (RTDs) based on a micro patterned thin film platinum resistor for experimental studies of the thermal impact to the wall. The sensors are located on an aluminium substrate, on which the platinum resistors and the electrical contact leads are embedded. The operational temperature range is below 0 °C up to 180 °C (in air), the temperature coefficient of resistivity (TCR) is 0.0014 °C−1 with a high linear correlation coefficient. The thermal time constant has been measured and studied using a one-dimensional finite element method. This sensor was applied in a test facility where two water streams of different temperatures and the same flow speed blend downstream of the rear edge of a splitter plate in a horizontal rectangular channel. It was used to measure and characterize in terms of frequency and amplitude the thermal fluctuations generated by the contact of the mixing patterns developed in the bulk of the flow with the channel side walls.  相似文献   

12.
《Tribology International》2012,45(12):1902-1919
Wear variations of Nimonic 80A slid against Incoloy 800HT between room temperature (RT) and 750 °C, and sliding speeds of 0.314 and 0.905 m s−1 were investigated using a ‘reciprocating-block-on-cylinder’, low debris retention configuration. These were considered alongside previous observations at 0.654 m s−1.Different wear types occurring were mapped, including high transfer ‘severe wear’ (RT and 270 °C, also 0.905 m s−1 at ≤570°C), low transfer ‘severe wear’ (0.314 m s−1 at 390 °C to 510 °C oxide abrasion assisted at 510 °C), and ‘mild wear’ (0.314 m s−1 at ≥570 °C; 0.905 m s−1 at ≥630 °C). Wear surfaces at 750 °C were cross-sectioned and profiled.  相似文献   

13.
A simplified technique using short term Fourier transform to reduce the errors in distributed temperature measurement with a Raman scattering based optical fiber sensor system is presented. The two main sources of errors are differential attenuation to anti-Stokes and Stokes signal by fiber and local change in Stokes due to change in temperature. The proposed technique compensates these errors and extracts correct temperature profile in spite of practical difficulties encountered in applying the theoretical concept. Moreover proposed technique is less complex, self-reliant, can tolerate variation in laser power, requires less dead zone and suits automation using embedded solution. Results of measurement carried out, using the system developed at RRCAT, Indore, for two hot zones having spatial width of 1.9 m (kept at 56 °C) and 1.5 m (kept at 78 °C), located at 47 m and 85 m respectively, show that these parameters can be recovered with significantly small errors.  相似文献   

14.
Fretting fatigue behavior of the sensitized SUS304 stainless steel under a pressurized hot water at 7.3 MPa and 288 °C was investigated. The tests were carried out under a contact pressure of 100 MPa and a frequency of 20 Hz. From the experimental result, combined effect of pressurized hot water and localized high tangential stress due to fretting resulted in nucleation of intergranular crack along the outer edge of contact region at lower stress amplitudes, while a fretting fatigue crack was nucleated at the highest tangential force point independently from these intergranular cracks at higher stress amplitudes. No intergranular crack nucleation was observed for fretting fatigue at the same temperature in air. The higher stress ratio reduced the fatigue strength, where the crack tip was exposed more in corrosive environment due to the high mean stress compared to the lower stress ratio.  相似文献   

15.
Wood plastic composites (WPCs) were produced from thermally treated beech (Fagus orientalis L.) wood and polypropylene (PP) polymer with coupling agent, by using injection molding. The wood chips were thermally treated for 30 or 120 min at three different temperatures (120 °C, 150 °C, or 180 °C) under saturated steam in a digester and then grounded (40-mesh size) by wood mill. Long-term water absorption kinetics of the composites were investigated with water immersion test. It was found that the water absorption decreased with increasing severity of the thermal-treatment and water immersion time as compared to the control composites. Furthermore, the composites produced with wood treated at 180 °C for 120 min exhibited the least water absorption. Microstructures of the composites were examined by SEM analysis to understand the mechanisms for the wood–plastic interaction which affected the water absorption. Further studies were conducted to model the water diffusion of the composites. Diffusion coefficient parameter in the models was obtained by fitting the model predictions with the experimental data. Water absorption of the studied composites was proved to follow the kinetics of a Fickian diffusion process.  相似文献   

16.
We demonstrate a simultaneous distributed strain and temperature measurement technique with the spatial resolution of 1 mm using fiber Bragg gratings inscribed in a polarization-maintaining and absorption-reducing fiber (PANDA-FBGs) and optical frequency domain reflectometry (OFDR). We conduct four-point bending tests in an environmental chamber. Using high birefringent PANDA-FBGs that are manufactured specifically for the simultaneous measurements, the uniform temperature distributions and the typical strain distribution profiles of the four-point bending tests were successfully obtained. The measurement errors of strain were from −31 με to 19 με, and of temperature were from −0.9 °C to 1.3 °C. The spatial standard deviation was 7.5 με and 0.9 °C. We also discussed the effect of the residual strain of the sensor-bonding procedures and the data averaging.  相似文献   

17.
In this study, high-velocity oxygen-fuel sprayed amorphous coatings have been heat treated at various temperatures to form microstructures with crystalline phases. The structure, micro-hardness, cavitation erosion resistance and erosion–corrosion resistance of these coatings are compared. Crystalline phases are discovered in the coatings after heat treatments at 650 °C and 750 °C. The coating heat treated at 750 °C exhibits the poorest cavitation erosion resistance in 3.5 wt% NaCl solution among all coatings due to the degraded corrosion resistance. However, the hardness of the crystallized coating can reach 1000 Hv and the erosion–corrosion resistance of the heat treated coating is better than the untreated one.  相似文献   

18.
The effect of Al2O3 content on the mechanical and tribological properties of Ni–Cr alloy was investigated from room temperature to 1000 °C. The results indicated that NiCr–40 wt% Al2O3 composite exhibited good wear resistance and its compressive strength remained 540 MPa even at 1000 °C. The values obtained for flexural strength and fracture toughness at room temperature were 771 MPa, 15.2 MPa m1/2, respectively. Between 800 °C and 1000 °C, the adhesive and plastic oxide layer on the worn surface of the composite was claimed to be responsible for low friction coefficient and wear rate.  相似文献   

19.
This article follows a previous study on friction and wear of 25CrMo4 steel [N. Khanafi-Benghalem, K. Loucif, E. Felder, F. Delamare, Influence de la température sur les mécanismes de frottement et d’usure des aciers X12NiCrMoSi25-20 et 25CrMo4 glissant sur du carbure de tungstène, Matériaux et techniques 93 (2005) 347–362]. The aim of our work is to study in more details the process of plastic deformation and the wear rate of this steel in lubricated sliding against cemented tungsten carbide, process observed in the previous work. The considered parameters are the temperature T (from 20 to 200 °C), the normal force P (from 500 to 1500 N), the steel structure (normalised HV 220 and quenched/tempered HV 480 states) and the sliding velocity v (from 0.05 to 0.3 m/s). We measured the friction coefficient and the sample total volume loss. A displacement sensor follows the volume loss evolution during the test; this follow-up is approximate because of the sample plastic flow which leads to the formation of peripheral burrs. All the tests conditions generate a significant plastic deformation of the sample steel, even in the quenched/tempered state: it produces a marked increase of the surface hardness, the work hardened layer being much finer for the quenched/tempered state (15 μm) than for the normalised state (40 μm at 20 °C). For temperatures T  100 °C in normalised state, the wear follows the Archard's law with an increasing rate with temperature. For T  120 °C, the wear rate decreases during the test, the global volume of wear being a decreasing function of T. For the quenched/tempered state, the wear rate decreases with the increase of the normal force, this decrease is less than 30% of the normalised state value. The material heating during the wear tests is well correlated with the friction dissipated power, but remains small, except in extreme cases (v maximum, great friction at high temperatures). These results suggest the existence of two wear mechanisms: abrasion by sample debris and burrs emission by plastic flow. The abrasion is probably the dominating mechanism for the tests carried out at the lowest temperatures. The plastic flow becomes a significant component at the highest temperatures. Using a contact model, we discuss to what extent the influence of the temperature and the strain rate on the steel hardness and ductility could explain the temperature and the sliding velocity effect on wear. Other phenomena are probably present: the influence of the steel microstructure and the lubricant on the size and/or the number of particles responsible for abrasion.  相似文献   

20.
Certain materials show a tribolayer formation especially at enhanced temperatures in abrasive environment, building a wear protection layer with the abrasive on the surface. Three materials with different microstructures were tested in three-body abrasive and impact/abrasive environments at temperatures up to 700 °C to investigate tribolayer formation. Optical and electron microscopical methods were used for wear qualification. Furthermore, hot hardness tests were performed up to 700 °C to investigate the influence of hardness drop on tribolayer formation.It was shown that no significant tribolayer formation occurs on grey cast iron, whereas other materials form tribolayers. Generally, tribolayer formation increases with increasing testing temperature, especially for austenitic and ferritic materials. This entails a self-protecting effect and thus superior wear resistance in abrasive environment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号