首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Bacterial biofilms play key roles in environmental and biomedical processes, and understanding their activities requires comprehension of their nanoarchitectural characteristics. Electron microscopy (EM) is an essential tool for nanostructural analysis, but conventional EM methods are limited in that they either provide topographical information alone, or are suitable for imaging only relatively thin (<300 nm) sample volumes. For biofilm investigations, these are significant restrictions. Understanding structural relations between cells requires imaging of a sample volume sufficiently large to encompass multiple cells and the capture of both external and internal details of cell structure. An emerging EM technique with such capabilities is bright‐field scanning transmission electron microscopy (BF‐STEM) and in the present report BF‐STEM was coupled with tomography to elucidate nanostructure in biofilms formed by the polycyclic aromatic hydrocarbon‐degrading soil bacterium, Delftia acidovorans Cs1‐4. Dual‐axis BF‐STEM enabled high‐resolution 3‐D tomographic recontructions (6–10 nm) visualization of thick (1250 and 1500 nm) sections. The 3‐D data revealed that novel extracellular structures, termed nanopods, were polymorphic and formed complex networks within cell clusters. BF‐STEM tomography enabled visualization of conduits formed by nanopods that could enable intercellular movement of outer membrane vesicles, and thereby enable direct communication between cells. This report is the first to document application of dual‐axis BF‐STEM tomography to obtain high‐resolution 3‐D images of novel nanostructures in bacterial biofilms. Future work with dual‐axis BF‐STEM tomography combined with correlative light electron microscopy may provide deeper insights into physiological functions associated with nanopods as well as other nanostructures.  相似文献   

2.
Off‐axis electron holography in the transmission electron microscope (TEM) is used to measure two‐dimensional electrostatic potentials in both unbiased and reverse biased silicon specimens that each contain a single p–n junction. All the specimens are prepared for examination in the TEM using focused ion beam (FIB) milling. The in situ electrical biasing experiments make use of a novel specimen geometry, which is based on a combination of cleaving and FIB milling. The design and construction of an electrical biasing holder are described, and the effects of TEM specimen preparation on the electrostatic potential in the specimen, as well as on fringing fields beyond the specimen surface, are assessed.  相似文献   

3.
Electron-holographic tomography (EHT), that is, the combination of off-axis electron holography with electron tomography, was successfully applied for the quantitative 3D mapping of electrostatic potentials at the nanoscale. Here we present the first software package (THOMAS) for semi-automated acquisition of holographic tilt series, a prerequisite for efficient data collection. Using THOMAS, the acquisition time for a holographic tilt series, consisting of object and reference holograms, is reduced by a factor of five on average, compared to the previous, completely manual approaches. Moreover, the existing software packages for retrieving amplitude and phase information from electron holograms have been extended, now including a one-step procedure for holographic tilt series reconstruction. Furthermore, a modified SIRT algorithm (WSIRT) was implemented for the quantitative 3D reconstruction of the electrostatic potential from the aligned phase tilt series. Finally, the application of EHT to a polystyrene latex sphere test-specimen and a pn-doped Ge ‘needle’-shaped specimen are presented, illustrating the quantitative character of EHT. For both specimens the mean inner potential (MIP) values were accurately determined from the reconstructed 3D potential. For the Ge specimen, additionally the ‘built-in’ voltage across the pn junction of 0.5 V was obtained.  相似文献   

4.
《Ultramicroscopy》2006,106(1):18-27
The three-dimensional (3D) morphology of a nanometer-sized object can be obtained using electron tomography. Variations in composition or density of the object cause variations in the reconstructed intensity. When imaging homogeneous objects, variations in reconstructed intensity are caused by the imaging technique, imaging conditions, and reconstruction. In this paper, we describe data acquisition, image processing, and 3D reconstruction to obtain and compare tomograms of magnetite crystals from bright field (BF) transmission electron microscopy (TEM), annular dark-field (ADF) scanning transmission electron microscopy (STEM), and high-angle annular dark field (HAADF) STEM tilt series. We use histograms, which plot the number of volume elements (voxels) at a given intensity vs. the intensity, to measure and quantitatively compare intensity distributions among different tomograms. In combination with numerical simulations, we determine the influence of maximum tilt angle, tilt increment, contrast changes with tilt (diffraction contrast), and the signal-to-noise ratio (SNR) as well as the choice of the reconstruction approach (weighted backprojection (WB) and sequential iterative reconstruction technique (SIRT)) on the histogram. We conclude that because ADF and HAADF STEM techniques are less affected by diffraction, and because they have a higher SNR than BF TEM, they are better suited for tomography of nanometer-sized crystals.  相似文献   

5.
A Monte Carlo electron-trajectory calculation has been implemented to assess the optimal detector configuration for scanning transmission electron microscopy (STEM) tomography of thick biological sections. By modeling specimens containing 2 and 3 at% osmium in a carbon matrix, it was found that for 1-μm-thick samples the bright-field (BF) and annular dark-field (ADF) signals give similar contrast and signal-to-noise ratio provided the ADF inner angle and BF outer angle are chosen optimally. Spatial resolution in STEM imaging of thick sections is compromised by multiple elastic scattering which results in a spread of scattering angles and thus a spread in lateral distances of the electrons leaving the bottom surface. However, the simulations reveal that a large fraction of these multiply scattered electrons are excluded from the BF detector, which results in higher spatial resolution in BF than in high-angle ADF images for objects situated towards the bottom of the sample. The calculations imply that STEM electron tomography of thick sections should be performed using a BF rather than an ADF detector. This advantage was verified by recording simultaneous BF and high-angle ADF STEM tomographic tilt series from a stained 600-nm-thick section of C. elegans. It was found that loss of spatial resolution occurred markedly at the bottom surface of the specimen in the ADF STEM but significantly less in the BF STEM tomographic reconstruction. Our results indicate that it might be feasible to use BF STEM tomography to determine the 3D structure of whole eukaryotic microorganisms prepared by freeze-substitution, embedding, and sectioning.  相似文献   

6.
The three-dimensional (3D) morphology of a nanometer-sized object can be obtained using electron tomography. Variations in composition or density of the object cause variations in the reconstructed intensity. When imaging homogeneous objects, variations in reconstructed intensity are caused by the imaging technique, imaging conditions, and reconstruction. In this paper, we describe data acquisition, image processing, and 3D reconstruction to obtain and compare tomograms of magnetite crystals from bright field (BF) transmission electron microscopy (TEM), annular dark-field (ADF) scanning transmission electron microscopy (STEM), and high-angle annular dark field (HAADF) STEM tilt series. We use histograms, which plot the number of volume elements (voxels) at a given intensity vs. the intensity, to measure and quantitatively compare intensity distributions among different tomograms. In combination with numerical simulations, we determine the influence of maximum tilt angle, tilt increment, contrast changes with tilt (diffraction contrast), and the signal-to-noise ratio (SNR) as well as the choice of the reconstruction approach (weighted backprojection (WB) and sequential iterative reconstruction technique (SIRT)) on the histogram. We conclude that because ADF and HAADF STEM techniques are less affected by diffraction, and because they have a higher SNR than BF TEM, they are better suited for tomography of nanometer-sized crystals.  相似文献   

7.
Electron tomography is a versatile method for obtaining three‐dimensional (3D) images with transmission electron microscopy. The technique is suitable to investigate cell organelles and tissue sections (100–500 nm thick) with 4–20 nm resolution. 3D reconstructions are obtained by processing a series of images acquired with the samples tilted over different angles. While tilting the sample, image shifts and defocus changes of several µm can occur. The current generation of automated acquisition software detects and corrects for these changes with a procedure that incorporates switching the electron optical magnification. We developed a novel method for data collection based on the measurement of shifts prior to data acquisition, which results in a five‐fold increase in speed, enabling the acquisition of 151 images in less than 20 min. The method will enhance the quality of a tilt series by minimizing the amount of required focus‐change compensation by aligning the optical axis to the tilt axis of the specimen stage. The alignment is achieved by invoking an amount of image shift as deduced from the mathematical model describing the effect of specimen tilt. As examples for application in biological and materials sciences 3D reconstructions of a mitochondrion and a zeolite crystal are presented.  相似文献   

8.
It is not straightforward to determine resolution for a 3D reconstruction when performing an electron tomography experiment. Different contributions such as missing wedge and misalignment add up and often influence the final resolution in an anisotropic manner. The conventional resolution measures can not be used for all of the reconstruction techniques, especially for iterative techniques which are more commonly used for electron tomography in materials science. Here we define a quantitative resolution measure that determines the resolution in three orthogonal directions of the reconstruction. As an application we use this measure to determine the optimum number of simultaneous iterative reconstruction technique (SIRT) iterations to reconstruct the gold nanoparticles, based on a high angle annular dark field STEM (HAADF-STEM) tilt series.  相似文献   

9.
10.
In this paper, we introduced a mathematical method for measuring the optical path length differences (OPDs), which is suitable for large OPD values where the fringes connections are difficult to detect. The proposed method is based on varying the width of the fringes, without changing the wavelength of the used coherent source. Also, in this work, we discussed the need for such method in off‐axis phase‐shifting digital holography. Low‐resolution off‐axis holograms failed to detect the correct interference order. In general, off‐axis phase‐shifting digital holography is limited by the resolution of the captured holograms. The results obtained using our proposed technique were compared to the results obtained using off‐axis phase‐shifting digital holograms and conventional two‐beam interferometry. Holograms were given for illustration.  相似文献   

11.
We report the successful implementation of a fully automated tomographic data collection system in scanning transmission electron microscopy (STEM) mode. Autotracking is carried out by combining mechanical and electronic corrections for specimen movement. Autofocusing is based on contrast difference of a focus series of a small sample area. The focus gradient that exists in normal images due to specimen tilt is effectively removed by using dynamic focusing. An advantage of STEM tomography with dynamic focusing over TEM tomography is its ability to reconstruct large objects with a potentially higher resolution.  相似文献   

12.
The early Caenorhabditis elegans embryo is currently a popular model system to study centrosome assembly, kinetochore organization, spindle formation, and cellular polarization. Here, we present and review methods for routine electron microscopy and 3D analysis of the early C. elegans embryo. The first method uses laser‐induced chemical fixation to preserve the fine structure of isolated embryos. This approach takes advantage of time‐resolved fixation to arrest development at specific stages. The second method uses high‐pressure freezing of whole worms followed by freeze‐substitution (HPF‐FS) for ultrastructural analysis. This technique allows staging of developing early embryos within the worm uterus, and has the advantage of superior sample preservation required for high‐resolution 3D reconstruction. The third method uses a correlative approach to stage isolated, single embryos by light microscopy followed by HPF‐FS and electron tomography. This procedure combines the advantages of time‐resolved fixation and superior ultrastructural preservation by high‐pressure freezing and allows a higher throughput electron microscopic analysis. The advantages and disadvantages of these methods for different applications are discussed.  相似文献   

13.
Electron tomography and electron holography experiments have been combined to investigate the 3D electrostatic potential distribution in semiconductor devices. The experimental procedure for the acquisition and data reconstruction of holographic tilt series of silicon p-n junction specimens is described. A quantitative analysis of the experimental results from specimens of two different thicknesses is presented, revealing the 3D electrostatic potential variations arising from the presence of surfaces and damage generated by focused ion beam (FIB) sample preparation. Close to bulk-like properties are measured in the centre of the tomographic reconstruction of the specimen, revealing higher electrically active dopant concentrations compared to the measurements obtained at the specimen surfaces. A comparison of the experimental results from the different thickness specimens has revealed a 'critical' thickness for this specimen preparation method of 350nm that is required for this device structure to retain 'bulk'-like properties in the centre of the membrane.  相似文献   

14.
Scanning transmission electron microscopy (STEM) tomography was applied to biological specimens such as yeast cells, HEK293 cells and primary culture neurons. These cells, which were embedded in a resin, were cut into 1-microm-thick sections. STEM tomography offers several important advantages including: (1) it is effective even for thick specimens, (2) 'dynamic focusing', (3) ease of using an annular dark field (ADF) mode and (4) linear contrasts. It has become evident that STEM tomography offers significant advantages for the observation of thick specimens. By employing STEM tomography, even a 1-microm-thick specimen (which is difficult to observe by conventional transmission electron microscopy (TEM)) was successfully analyzed in three dimensions. The specimen was tilted up to 73 degrees during data acquisition. At a large tilt angle, the specimen thicknesses increase dramatically. In order to observe such thick specimens, we introduced a special small condenser aperture that reduces the collection angle of the STEM probe. The specimen damage caused by the convergent electron beam was expected to be the most serious problem; however, the damage in STEM was actually smaller than that in TEM. In this study, the irradiation damage caused by TEM- and STEM-tomography in biological specimens was quantitatively compared.  相似文献   

15.
The evolution of hydrogen from many hydrated cryo‐preserved soft materials under electron irradiation in the transmission electron microscope can be observed at doses of the order of 1000 e nm?2 and above. Such hydrogen causes artefacts in conventional transmission electron microscope or scanning transmission electron microscopy (STEM) imaging as well as in analyses by electron energy‐loss spectroscopy. Here we show that the evolution of hydrogen depends on specimen thickness. Using wedge‐shaped specimens of frozen‐hydrated Nafion, a perfluorinated ionomer, saturated with the organic solvent DMMP together with both thin and thick sections of frozen‐hydrated porcine skin, we show that there is a thickness below which hydrogen evolution is not detected either by bubble observation in transmission electron microscope image mode or by spectroscopic analysis in STEM electron energy‐loss spectroscopy mode. We suggest that this effect is due to the diffusion of hydrogen, whose diffusivity remains significant even at liquid nitrogen temperature over the length scales and time scales relevant to transmission electron microscopy analysis of thin specimens. In short, we speculate that sufficient hydrogen can diffuse to the specimen surface in thin sections so that concentrations are too low for bubbling or for spectroscopic detection. Significantly, this finding indicates that higher electron doses can be used during the imaging of radiation‐sensitive hydrated soft materials and, consequently, higher spatial resolution can be achieved, if sufficiently thin specimens are used in order to avoid the evolution of hydrogen‐based artefacts.  相似文献   

16.
The genesis, theoretical basis and practical application of the new electron holographic dark-field technique for mapping strain in nanostructures are presented. The development places geometric phase within a unified theoretical framework for phase measurements by electron holography. The total phase of the transmitted and diffracted beams is described as a sum of four contributions: crystalline, electrostatic, magnetic and geometric. Each contribution is outlined briefly and leads to the proposal to measure geometric phase by dark-field electron holography (DFEH). The experimental conditions, phase reconstruction and analysis are detailed for off-axis electron holography using examples from the field of semiconductors. A method for correcting for thickness variations will be proposed and demonstrated using the phase from the corresponding bright-field electron hologram.  相似文献   

17.
Properties of a composite material made of a continuous matrix and particles often depend on microscopic details, such as contacts between particles. Focusing on processing raw focused‐ion beam scanning electron microscope (FIB‐SEM) tomography data, we reconstructed three mixed‐matrix membrane samples made of 6FDA‐ODA polyimide and silicalite‐1 particles. In the first step of image processing, backscattered electron (BSE) and secondary electron (SE) signals were mixed in a ratio that was expected to obtain a segmented 3D image with a realistic volume fraction of silicalite‐1. Second, after spatial alignment of the stacked FIB‐SEM data, the 3D image was smoothed using adaptive median and anisotropic nonlinear diffusion filters. Third, the image was segmented using the power watershed method coupled with a seeding algorithm based on geodesic reconstruction from the markers. If the resulting volume fraction did not match the target value quantified by chemical analysis of the sample, the BSE and SE signals were mixed in another ratio and the procedure was repeated until the target volume fraction was achieved. Otherwise, the segmented 3D image (replica) was accepted and its microstructure was thoroughly characterized with special attention paid to connectivity of the silicalite phase. In terms of the phase connectivity, Monte Carlo simulations based on the pure‐phase permeability values enabled us to calculate the effective permeability tensor, the main diagonal elements of which were compared with the experimental permeability. In line with the hypothesis proposed in our recent paper (?apek, P. et al. (2014) Comput. Mater. Sci. 89 , 142–156), the results confirmed that the existence of particle clusters was a key microstructural feature determining effective permeability.  相似文献   

18.
Electron tomography requires a wide angular range of specimen-tilt for a reliable three-dimensional (3D) reconstruction. Although specimen holders are commercially available for tomography, they have several limitations, including tilting capability in only one or two axes at most, e.g. tilt-rotate. For amorphous specimens, the image contrast depends on mass and thickness only and the single-tilt holder is adequate for most tomographic image acquisitions. On the other hand, for crystalline materials where image contrast is strongly dependent on diffraction conditions, current commercially available tomography holders are inadequate, because they lack tilt capability in all three orthogonal axes needed to maintain a constant diffraction condition over the whole tilt range. We have developed a high-angle triple-axis (HATA) tomography specimen holder capable of high-angle tilting for the primary horizontal axis with tilting capability in the other (orthogonal) horizontal and vertical axes. This allows the user to trim the specimen tilt to obtain the desired diffraction condition over the whole tilt range of the tomography series. To demonstrate its capabilities, we have used this triple-axis tomography holder with a dual-axis tilt series (the specimen was rotated by 90° ex-situ between series) to obtain tomographic reconstructions of dislocation arrangements in plastically deformed austenitic steel foils.  相似文献   

19.
Elemental mapping in the energy filtering transmission electron microscope (EFTEM) can be extended into three dimensions (3D) by acquiring a series of two‐dimensional (2D) core‐edge images from a specimen oriented over a range of tilt angles, and then reconstructing the volume using tomographic methods. EFTEM has been applied to imaging the distribution of biological molecules in 2D, e.g. nucleic acid and protein, in sections of plastic‐embedded cells, but no systematic study has been undertaken to assess the extent to which beam damage limits the available information in 3D. To address this question, 2D elemental maps of phosphorus and nitrogen were acquired from unstained sections of plastic‐embedded isolated mouse thymocytes. The variation in elemental composition, residual specimen mass and changes in the specimen morphology were measured as a function of electron dose. Whereas 40% of the total specimen mass was lost at doses above 106 e?/nm2, no significant loss of phosphorus or nitrogen was observed for doses as high as 108 e?/nm2. The oxygen content decreased from 25 ± 2 to 9 ± 2 atomic percent at an electron dose of 104 e?/nm2, which accounted for a major component of the total mass loss. The specimen thickness decreased by 50% after a dose of 108 e?/nm2, and a lateral shrinkage of 9.5 ± 2.0% occurred from 2 × 104 to 108 e?/nm2. At doses above 107 e?/nm2, damage could be observed in the bright field as well in the core edge images, which is attributed to further loss of oxygen and carbon atoms. Despite these artefacts, electron tomograms obtained from high‐pressure frozen and freeze‐substituted sections of C. elegans showed that it is feasible to obtain useful 3D phosphorus and nitrogen maps, and thus to reveal quantitative information about the subcellular distributions of nucleic acids and proteins.  相似文献   

20.
Yu Z  Muller DA  Silcox J 《Ultramicroscopy》2008,108(5):494-501
Annular dark field scanning transmission electron microscopy (ADF-STEM) imaging of a crystal depends strongly on specimen orientation, but for an amorphous sample it is insensitive to orientation changes. To fully investigate the effects of specimen tilt, an interface of amorphous Si (a-Si) and crystalline Si (c-Si) was rotated systematically off a zone axis in a STEM equipped with low-angle ADF (LAADF) and high-angle ADF (HAADF) detectors. The change of relative intensity across the interface shows very different trends in the LAADF and the HAADF images upon tilting. More importantly, it is found that the HAADF signal decreases much more rapidly when tilted off a zone axis than does the LAADF signal. The high-resolution lattice fringes also disappear much faster in the HAADF image than in the LAADF image. These trends reflect the fact that the channeling peaks that are responsible for scattering into the HAADF detector decrease more quickly upon tilting than the lower angle scattering to the LAADF detector does.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号