首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   983篇
  免费   0篇
电工技术   2篇
化学工业   1篇
金属工艺   5篇
机械仪表   1篇
建筑科学   5篇
能源动力   6篇
水利工程   18篇
石油天然气   1篇
无线电   21篇
一般工业技术   19篇
冶金工业   12篇
原子能技术   5篇
自动化技术   887篇
  2016年   1篇
  2011年   791篇
  2010年   31篇
  2009年   59篇
  2008年   1篇
  1999年   1篇
  1998年   78篇
  1997年   18篇
  1996年   3篇
排序方式: 共有983条查询结果,搜索用时 234 毫秒
31.
The characterization of an optical sensor membrane is described for simultaneous determination of sulfite and sulfide ions based on the immobilization of crystal violet on a triacetylcellulose membrane. The absorbance of the membranes decreased by increasing sulfite and sulfide concentration. The partial least squares (PLS-1) calibration model based on spectrophotometric measurement for simultaneous determination of sulfite and sulfide ions was applied. This method is based on the difference between the rate of the reaction of sulfide and sulfite with membranes in pH 7.0 buffer solution and at 25 °C. The experimental calibration matrix for partial least squares (PLS-1) calibration was designed with 18 samples. The cross-validation method was used for selecting the number of factors. The results showed that simultaneous determination could be performed in the range of 200–2000 μg mL−1 (2.5–25 mmol L−1) and 80–900 μg mL−1 (2.5–28.125 mmol L−1) for sulfite and sulfide, respectively. The sensor can readily be regenerated with water and the color is fully reversible. The sensor was successfully applied to the simultaneous determination of sulfide and sulfite in water samples.  相似文献   
32.
Well-aligned zinc oxide (ZnO) nanowire arrays were fabricated on gold-coated plastic substrates using a low-temperature aqueous chemical growth (ACG) method. The ZnO nanowire arrays with 50–130 nm diameters and ∼1 μm in lengths were used in an enzyme-based urea sensor through immobilization of the enzyme urease that was found to be sensitive to urea concentrations from 0.1 mM to 100 mM. Two linear sensitivity regions were observed when the electrochemical responses (EMF) of the sensors were plotted vs. the logarithmic concentration range of urea from 0.1 mM to 100 mM. The proposed sensor showed a sensitivity of 52.8 mV/decade for 0.1–40 mM urea and a fast response time less than 4 s was achieved with good selectivity, reproducibility and negligible response to common interferents such as ascorbic acid and uric acid, glucose, K+ and Na+ ions.  相似文献   
33.
In this study, we report on multi-walled carbon nanotubes fabricated on silicon substrate with four different orientations via chemical vapor deposition. It is well-known that chemical treatments improve the nanotube electrochemical reactivity by creating edge-like defects on their exposed sidewalls. Before use, we performed an acid treatment on carbon nanotubes. To prove the effect of the treatment on these nanostructured electrodes, contact angles were measured. Then, sensitivities and detection limits were evaluated performing cyclic voltammetry. Two target molecules were used: potassium ferricyanide, an inorganic electroactive molecule, and hydrogen peroxide that is a product of reactions catalyzed by many enzymes, such as oxidases and peroxidases. Carbon nanotubes with tilted tips become hydrophilic after the treatment showing a contact angle of 22° ± 2°. This kind of electrode has shown also the best electrochemical performance. Sensitivity and detection limit values are 110.0 ± 0.5 μA/(mM cm2) and 8 μM for potassium ferricyanide solutions and 16.4 ± 0.1 μA/(mM cm2) and 24 μM using hydrogen peroxide as target compound. Considering the results of wettability and voltammetric measurements, nanotubes with tilted tips-based electrodes are found to be the most promising for future biosensing applications.  相似文献   
34.
Nanoparticle-assembled ZnO micro-octahedrons were synthesized by a facile homogeneous precipitation method. The ZnO micro-octahedrons are hexagonal wurtzite with high crystallinity. Abundant structure defects were confirmed on ZnO surface by photoluminescence. Gas sensors based on the ZnO micro-octahedrons exhibited high response, selectivity and stability to 1–1000 ppm formaldehyde at 400 °C. Especially, even 1 ppm formaldehyde could be detected with high response (S = 22.7). It is of interest to point out that formaldehyde could be easily distinguished from ethanol or acetaldehyde with a selectivity of about 3. The high formaldehyde response is mainly attributed to the synergistic effect of high contents of electron donor defects (Zni and VO) and highly active oxygen species (O2−) on the ZnO surface.  相似文献   
35.
A new kind of molecularly imprinted polymer-modified graphite electrode was fabricated by “grafting-to” approach, incorporating sol–gel technique, for the detection of acute deficiency in serum ascorbic acid level (SAAL), manifesting hypovitaminosis C. The modified electrode exhibited ascorbic acid (AA) oxidation at less positive potential (0.0 V) than the earlier reported methods, resulting in a limit of detection as low as 6.13 ng mL−1 (RSD = 1.2%, S/N = 3). The diffusion coefficient (1.096 × 10−5 cm2 s−1), rate constant (7.308 s−1), and Gibb's free energy change (−12.59 kJ mol−1) due to analyte adsorption, were also calculated to explore the kinetics of AA oxidation. The proposed sensor was found to enhance sensitivity substantially so as to detect ultra trace level of AA in the presence of other biologically important compounds (dopamine, uric acid, etc.), without any cross interference and matrix complications from biological fluids and pharmaceutical samples.  相似文献   
36.
As the design of label-free DNA biosensors matures, and their sizes reduced to enhance their sensitivity, not much has been researched about the variations in the received signal with the positioning of the probes on the sensitive surface. We approach this issue computationally in this paper. By adopting the finite-element model on a three-dimensional biological field-effect transistor (BioFET) slice, and running Monte-Carlo simulations on the positions of the DNA molecules, we extract the expected variations in the signal. Then, we show that signal-to-noise (SNR) ratio can be low enough to hinder the functionality of the device, placing a limitation on how low the sensitivity of a sensor of a certain size can be.  相似文献   
37.
Y. Lu  W. Ren  S. Yi  Y. ZuoAuthor vitae 《Neurocomputing》2011,74(18):3768-3772
This paper addresses the analysis problem of asymptotic stability for a class of uncertain neural networks with Markovian jumping parameters and time delays. The considered transition probabilities are assumed to be partially unknown. The parameter uncertainties are considered to be norm-bounded. A sufficient condition for the stability of the addressed neural networks is derived, which is expressed in terms of a set of linear matrix inequalities. A numerical example is given to verify the effectiveness of the developed results.  相似文献   
38.
Ordered mesoporous SnO2 and mesoporous Pd/SnO2 have been successfully synthesized via nanocasting method using the hexagonal mesoporous SBA-15 as template. Two different procedures, impregnation technique and direct synthesis, were utilized for the doping of Pd in the mesoporous SnO2. The results of small angle X-ray diffraction (SAXD), nitrogen adsorption–desorption and transmission electron microscopy (TEM) demonstrate that the SnO2 and Pd/SnO2 display ordered mesoporous structures and high surface areas. Wide angle X-ray diffraction (WAXD) and X-ray photoelectron spectroscopy (XPS) reveal tetragonal structure of SnO2 and the existence of Pd element. The sensing properties of mesoporous SnO2 and mesoporous Pd/SnO2 for H2 were detected. The sensor utilizing mesoporous Pd/SnO2 via direct synthesis method exhibits excellent response and recovery behavior and much higher sensitivity to H2, compared to those using mesoporous SnO2 and mesoporous Pd/SnO2 via impregnation technique. It is believed that its high gas sensing performance is derived from the large surface area, high activity and well dispersion of Pd additive, as well as high porosity, which lead to highly effective surface interaction between the target gas molecules and the surface active sites.  相似文献   
39.
Electronic nose has been widely used in the classification of liquid samples, such as vinegars, wines and liquors, which have complex components. The difficulty of these classifications is how to get the information of the trace components in these samples. In this paper a method for liquor recognition based on liquid evaporation was presented. This method makes use of the distinct evaporation characteristics of different components in liquor samples. And during the evaporation process, one metal oxide gas sensor was used to detect the headspace of liquor samples for classification. Due to the distinct evaporation characteristics of different components, volatile compounds in the headspace evaporating from samples would change with the testing time. Meanwhile, the gas sensor would respond to these volatile compounds. Accordingly, more information of liquor samples during evaporation may be acquired with the proposed method. To verify the performance of this method, 8 different Chinese liquors with 50% alcohol for comparison were tested under the method. The results showed that the evaporation characteristics of these liquor samples were quite distinct. The correct classification accuracy of discriminant function analysis was 100%, which indicated this method may be a simple and effective way for complex-component liquid sample analysis.  相似文献   
40.
With the advent of new haptic feedback devices, researchers are giving serious consideration to the incorporation of haptic communication in collaborative virtual environments. For instance, haptic interactions based tools can be used for medical and related education whereby students can train in minimal invasive surgery using virtual reality before approaching human subjects. To design virtual environments that support haptic communication, a deeper understanding of humans′ haptic interactions is required. In this paper, human′s haptic collaboration is investigated. A collaborative virtual environment was designed to support performing a shared manual task. To evaluate this system, 60 medical students participated to an experimental study. Participants were asked to perform in dyads a needle insertion task after a training period. Results show that compared to conventional training methods, a visual-haptic training improves user′s collaborative performance. In addition, we found that haptic interaction influences the partners′ verbal communication when sharing haptic information. This indicates that the haptic communication training changes the nature of the users′ mental representations. Finally, we found that haptic interactions increased the sense of copresence in the virtual environment: haptic communication facilitates users′ collaboration in a shared manual task within a shared virtual environment. Design implications for including haptic communication in virtual environments are outlined.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号