排序方式: 共有14条查询结果,搜索用时 15 毫秒
1.
This study examines experimentally the effect of stators on the performance and heat transfer characteristics of small axial cooling fans. A single fan impeller, followed by nine stator blades in the case of a complete stage, was used for all the experimental configurations. Performance measurements were carried out in a constant speed stage performance test rig while the transient liquid crystal technique was used for the heat transfer measurements. Full surface heat transfer coefficient distributions were obtained by recording the temperature history of liquid crystals on a target plate. The experimental data indicated that the results are highly affected by the flow conditions at the fan outlet. Stators can be beneficial in terms of pressure drop and efficiency, and thus more economical operation, as well as, in the local heat transfer distribution at the wake of the stator blades if the fan is installed very close to the cooling object. However, as the separation distance increases, enhanced heat transfer rate in the order of 25% is observed in the case of the fan impeller. 相似文献
2.
针对三峡左岸电站发电机定子纯水冷却系统存在的电磁泵频繁烧损和内部控制流程设计缺陷等问题,进行了大量的研究和试验,实施了采用软启动方式、改造膨胀水箱、修改纯水系统控制逻辑等一系列改进措施,有一定的工程有效性。 相似文献
3.
Brushless three-phase synchronous motor involving a rotating ac exciter on the same shaft as the motor and with the windings linked through a shaft-mounted rectifier is widely used as medium and large capacity machines. However, the motor needs to fit with damping windings for self-starting outside of the field winding in the rotor and needs to equip discharge resistance with complex electronic device to dispose of electromagnetic force induced in the field winding at starting. Therefore, the rotor structure is very complex, and there are disadvantages, especially for the robust and highly reliable motor that is desired. To solve the problem found in traditional motors, the authors proposed a brushless three-phase synchronous induction motor with two stators and one wound rotor. This problem is solved because the proposed motor is of two-stators structure: the rotor winding operates as a secondary winding of induction motor at starting and as the field winding at synchronous operation. The motor can self-start as a wound-rotor induction motor without external secondary resistance. Therefore, discharge resistance is not necessary; the starting equipment is very simple and the rotor structure is robust. It is possible to start with high torque. In this paper, the basic constitution of the proposed motor and the principles of operation are described in detail. The experimental results at starting and pulling into synchronism are shown for confirming the principles of operation and the experimental and numerical results of the starting characteristics. The load ones and the generating ones are shown and then the practical use of the proposed motor is confirmed. 相似文献
4.
5.
针对山地风电场大型永磁同步风电机组发电机定子温度的变化特点及传热过程进行分析,提出一种基于风电机组SCADA数据的发电机定子温度建模方法。首先,分析风电机组在实际运行过程中定子温度的变化情况;然后,根据永磁同步发电机内部的传热过程,对发电机定子温度建模;最后,采用风电机组正常运行时的SCADA数据求解模型参数。实例分析表明,风电机组状态正常时,定子温度估计的平均误差绝对值为0.59 ℃,模型精度较高;风电机组状态异常时,模型温度估计的平均误差绝对值为5.17 ℃,精度显著降低。 相似文献
6.
电机定子低阶固有频率计算 总被引:1,自引:0,他引:1
通过对叠层圆筒振动特性的讨论 ,归纳出电机定子振动的低阶平面模态特性。在计及定子各部分动能和势能的基础上 ,运用拉格朗日方程建立相应的频率方程 ,求得定子振动低阶固有频率。实验结果验证了理论预测结果。本文的方法可用在电机设计阶段对定子固有频率进行预测。 相似文献
7.
翟明久 《西安工业学院学报》1992,12(2):37-45
对直线式感应同步器滑尺的四种绕组产生的磁势作了分析,得出各种绕组产生的各次谐波磁势表达式.左此基础上,提出了选择定尺连续输出绕组跨距的理想数值,以及消除谐波,提高测量精度的方法. 相似文献
8.
9.
吴洪飞 《水电自动化与大坝监测》2011,35(2)
针对三峡左岸电站发电机定子纯水冷却系统存在的电磁泵频繁烧损和内部控制流程设计缺陷等问题,进行了大量的研究和试验,实施了采用软启动方式、改造膨胀水箱、修改纯水系统控制逻辑等一系列改进措施,有一定的工程有效性. 相似文献
10.
新型双定子横向磁通直线振荡电机 总被引:1,自引:0,他引:1
现有圆筒型非横向磁通式直线振荡电机因铁心冲片叠装困难、动磁式永磁体支架性能要求高及行程短限制了其在低成本及高控制性能要求领域中的应用。该文提出的新型双定子横向磁通直线振荡电机克服了这些缺点,适用于冰箱、空气压缩机等民用产品。建立线性数学模型及准二维有限元模型,求出了力与电流的正比关系式,理论分析结果与实验结果相符。通过三组实测的振幅、电流与频率间变化曲线分析了电机实际振动频率与弹簧弹性系数的关系及系统的共振频率。 相似文献