The penalized calibration technique in survey sampling combines usual calibration and soft calibration by introducing a penalty term. Certain relevant estimates in survey sampling can be considered as penalized calibration estimates obtained as particular cases from an optimization problem with a common basic structure. In this framework, a case deletion diagnostic is proposed for a class of penalized calibration estimators including both design-based and model-based estimators. The diagnostic compares finite population parameter estimates and can be calculated from quantities related to the full data set. The resulting diagnostic is a function of the residual and leverage, as other diagnostics in regression models, and of the calibration weight, a singular feature in survey sampling. Moreover, a particular case, which includes the basic unit level model for small area estimation, is considered. Both a real and an artificial example are included to illustrate the diagnostic proposed. The results obtained clearly show that the proposed diagnostic depends on the calibration and soft-calibration variables, on the penalization term, as well as on the parameter to estimate. 相似文献
A new and original method of calibrating helium leaks that makes it possible to take into account the existence of a number of auxiliary phenomena is described. For this purpose, a hollow leak the purpose of which is to reproduce only desorbed gas flows, is introduced into the vacuum system of the calibration bench. Analysis of the results of corresponding cumulation measurements makes it possible to introduce corrections for these phenomena. 相似文献
In many applications electronic sensors are used toimprove performance and reliability of measurement systems. Suchsensors should provide a correct transfer from the physical signalto be measured to the electrical output signal. One importantstep to achieve this, is to calibrate each sensor by applyingdifferent reference input signals and adjusting the sensor transferaccordingly. Besides expensive reference equipment the calibrationprocess takes much time and attention per individual sensor,which means a considerable increase in sensor production costs.By including at the sensor or sensor interface chip a programmablecalibration facility the calibration of such smart sensors caneasily be automated and can be executed for a batch of sensorsat a time, thus minimizing the calibration time and costs. Thispaper presents a calibration method and options for integrationin the smart sensor concept, in hardware as well as in software.An advantage of the proposed method is that it does not needa large matrix of calibration data, which needs to be storedin a look-up table or converted into a correction formula, butinstead it uses a step-by-step approach to correct the sensortransfer at each calibration measurement until the error is sufficientlysmall. 相似文献
The main purpose of this paper is to find the mixed-mode stress intensity factors of composite materials using the crack opening displacement (COD). First, a series solution of the composite material with a crack was used to evaluate COD values. Then, the least-squares method was used to calculate mixed-mode stress intensity factors. This algorithm can be applied to any method that generates or measures COD values. The major advantage of this method is that COD values very near the crack tip are not necessary. Both finite element simulations and laboratory experiments were applied to validate this least-squares method with acceptable accuracy if the even terms of the series solution are removed. 相似文献
Camera calibration is the first step of three-dimensional machine vision. A fundamental parameter to be calibrated is the position of the camera projection center with respect to the image plane. This paper presents a method for the computation of the projection center position using images of a translating rigid object, taken by the camera itself.
Many works have been proposed in literature to solve the calibration problem, but this method has several desirable features. The projection center position is computed directly, independently of all other camera parameters. The dimensions and position of the object used for calibration can be completely unknown.
This method is based on a geometric relation between the projection center and the focus of expansion. The use of this property enables the problem to be split into two parts. First a suitable number of focuses of expansion are computed from the images of the translating object. Then the focuses of expansion are taken as landmarks to build a spatial back triangulation problem, the solution of which gives the projection center position. 相似文献