排序方式: 共有4条查询结果,搜索用时 93 毫秒
1
1.
Mohammed A. Quader Dhiren Kumar Keyur B. Shah Yahya I. Fatani Gundars Katlaps Vigneshwar Kasirajan 《Hemodialysis international. International Symposium on Home Hemodialysis》2014,18(1):205-209
Dialysis centers adopt a cautious approach when it comes to performing intermittent hemodialysis (HD) on patients with continuous flow (CF) left ventricular assist devices (LVADs) because of the potential for volume flux‐related complications and absence of pulsatile blood pressure for monitoring. Many patients have to remain hospitalized because of the inability of the dialysis centers to accept them for outpatient dialysis. In this study, the effect of HD was observed in such patients. Between June 2009 and October 2012, 139 patients received LVADs, of which 10 patients (7%) required intermittent HD postoperatively. The mean age of the patients was 53 ± 14 years and 90% were men. A total of 281 dialysis sessions were administered amounting to 1025 hours of dialysis. The mean systolic blood pressure monitored with Doppler device was 97 ± 18 mmHg. Dialysis durations averaged 218 ± 18 minutes. Mean blood flow rate was 334 ± 38 cc/min, and 2.6 ± 1.1 L was ultrafiltrated during each session. Only 15 (5.3%) sessions were interrupted or terminated in six patients. The reasons for termination were symptomatic hypotension—6 (2.1%), asymptomatic hypotension—3 (1%), ventricular tachycardia—1 (0.36%), dialysis machine malfunction—2 (0.7%), low phosphorus—2 (0.7%), and abdominal cramps—1 (0.36%). Volume expansion was necessary on three occasions. Low‐flow device alarms were registered during two (0.71%) sessions. The results showed no serious adverse effects or deaths. 相似文献
2.
Native arteriovenous fistula placement in three patients after implantation of a left ventricular assist device with non‐pulsatile blood flow 下载免费PDF全文
Johannes F. Schaefers Christian Ertmer 《Hemodialysis international. International Symposium on Home Hemodialysis》2017,21(3):E54-E57
Patients with left ventricular assist device have an increased risk for postoperative acute kidney injury and long‐term requirement of dialysis. As a chronic access for dialysis, native arteriovenous fistulae are uncommon options due to suspected maturation failure. We present three patients who received successful arteriovenous fistulae placement after left ventricular assist device implantation with assisted long term patency. 相似文献
3.
4.
Claudio De Lazzari Igino Genuini Bernhard Quatember Francesco Fedele 《Computer methods and programs in biomedicine》2014
Patients assisted with left ventricular assist device (LVAD) may require prolonged mechanical ventilatory assistance secondary to postoperative respiratory failure. The goal of this work is the study of the interdependent effects LVAD like pulsatile catheter (PUCA) pump and mechanical ventilatory support or thoracic artificial lung (TAL), by the hemodynamic point of view, using a numerical simulator of the human cardiovascular system. In the simulator, different circulatory sections are described using lumped parameter models. Lumped parameter models have been designed to describe the hydrodynamic behavior of both PUCA pump and thoracic artificial lung. Ventricular behavior atrial and septum functions were reproduced using variable elastance model. Starting from simulated pathological conditions we studied the effects produced on some hemodynamic variables by simultaneous PUCA pump, thoracic artificial lung or mechanical ventilation assistance. Thoracic artificial lung was applied in parallel or in hybrid mode. The effects of mechanical ventilation have been simulated by changing mean intrathoracic pressure value from −4 mmHg to +5 mmHg. The hemodynamic variables observed during the simulations, in different assisted conditions, were: left and right ventricular end systolic (diastolic) volume, systolic/diastolic aortic pressure, mean pulmonary arterial pressure, left and right mean atrial pressure, mean systemic venous pressure and the total blood flow. Results show that the application of PUCA (without mechanical ventilatory assistance) increases the total blood flow, reduces the left ventricular end systolic volume and increases the diastolic aortic pressure. Parallel TAL assistance increases the right ventricular end diastolic (systolic) volume reduction both when PUCA is switched “ON” and both when PUCA is switched “OFF”. By switching “OFF” the PUCA pump, it seems that parallel thoracic artificial lung assistance produces a greater cardiac output (respect to hybrid TAL assistance). 相似文献
1