首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   2篇
  免费   0篇
综合类   2篇
  2009年   1篇
  2008年   1篇
排序方式: 共有2条查询结果,搜索用时 0 毫秒
1
1.
A measurement system has been developed based on high-precision printed probes in printed circuit board (PCB) and steep rising-time probe adapters,which can be applied to study the expansion uniformity of armature in a helical magnetic flux compression generator (HFCG).The influences of wall thickness and initiation position on the expansion uniformity of armature in HFCG were experimentally investigated.The results show that the armature with thinner wall thickness will easily rupture due to the high pressure of detonation products inside,the armature with larger wall thickness will easily crack due to the tensile stress on the outer surface of the wall,the influence of the end effect on the expansion uniformity can be ignored if the distance between the first group of probe and the initiation point is more than 3 times the armature diameter.  相似文献   
2.
High-power precise delay trigger/ignition system is a programmable pulse generator developed for experiment controlling in explosively driven magnetic flux compression generators. Precise delay pulses are generated by the digital circuit, after being magnified and sharpened through multistage isolated amplifiers and rising edge sharpening device, high-voltage steep delay pulses with precision less than μs level are obtained. This system has been used in our compact magnetic flux compression generator experiments in place of the traditional primaeord delay device.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号