排序方式: 共有9条查询结果,搜索用时 15 毫秒
1
1.
The particle diffusion coefficient and the convection velocity were studied based on the density modulation using D2 gas puffing on the HT-7 tokamak. The density was measured by a five-channel FIR interferometer. The density modulation amplitude was 10% of the central chord averaged background density and the modulation frequency was 10 Hz in the experiments. The particle diffusion coefficient (D) and the convection velocity (V) were obtained for different background plasmas with the central chord averaged density 〈ne〉 = 1.5×10^19m^-3 and 3.0×10^19 m^-3 respectively. It was observed that the influence of density modulation on the main plasma parameters was very weak. This technology is expected to be useful for the analysis of LHW and IBW heated plasmas on HT-7 tokamak in the near future. 相似文献
2.
1. IntroductionHefei tokamak:7 (HT-7) is a super-conductingtokamak device which was rebuilt from the originalRussian T-7 tokamak in 1994. Recently a feedbackcontrol system to simultaneously control plasma current, density and displacement has been developedon the HT-7 and put into daily operation. HT-7with R = 1.22 m, a = 0.26 ~0.30 m has afstainless steel liner, and two immovable and two movablestainless steel liciters (including a movable liciter)with molybdenum tips. There are two layer… 相似文献
3.
简要介绍了用于国家中型超导托卡马克装置HT-7弹丸注入系统;详细阐述了在HT-7装置首次用于加料实验的氘(D2)丸的成冰工艺、氘丸注入实验以及氘丸注入对等离子体产生的影响;研究了等离子体的密度、温度的分布变化。 相似文献
4.
5.
太赫兹连续波DCN激光器的实验研究 总被引:1,自引:1,他引:0
介绍了运行在1.54THz(195μm)和1.58THz(190μm)的波导型辉光放电激励的大功率连续波DCN激光器的开发和研制工作.该激光器的谐振腔长3.4m,放电长度3m,谐振腔由耐热玻璃制成,直径54mm.谐振腔一端为平面反射镜,一端为金属栅网.工作气体为N2,CD4和He(或D2)的混合气体,在1.54THz的连续激光输出功率大于0.2W.实验中对放电电流、激光管温度、气压等参数进行了优化,研究了EH11模DCN激光在自由空间的传输特性.研究表明,利用新的N2,CD4和D2混合气体的太赫兹DCN激光器可以得到稳定连续的高功率放电.光束传输远场满足高斯分布(z>4m),对各种参数进行优化后,190μm和195μm窗口处输出EH11模功率分别为0.15W和0.16W,可以满足超导托卡马克连续运行的干涉测量的需要. 相似文献
6.
7.
A single-channel far-infrared (FIR) laser interferometer was developed to measure the line averaged electron density on the EAST tokamak. The structure of the single-channel FIR laser interferometer is described in detail. The evolution of density sawtooth oscillation was measured by means the FIR laser interferometer, and was identified by electron cyclotron emission (ECE) signals and soft X-ray intensity. The discharges with and without sawtooth were compared with each other in the Hugill diagram. 相似文献
8.
9.
1. IntroductionHigh-density plasma are of interest in thermonuclear fusion research. Fusion plasma density canbe measured by FIR laser and submillimeter waveinterferometer [l]. Plasma are transparent as longas the plasma frequency wp is smaller than the frequency w of the probe wave. The index of refractionof a medium is easily measurable by using electromagnetic waves for which the medium is transparent [l,21. The values of tile index of refraction, po,correspond to a polarized wave with it… 相似文献
1