首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   31篇
  免费   0篇
电工技术   1篇
建筑科学   4篇
能源动力   12篇
无线电   4篇
一般工业技术   1篇
自动化技术   9篇
  2021年   1篇
  2019年   1篇
  2017年   1篇
  2016年   2篇
  2013年   2篇
  2011年   3篇
  2010年   1篇
  2009年   2篇
  2008年   1篇
  2007年   4篇
  2006年   1篇
  2002年   1篇
  2000年   1篇
  1999年   1篇
  1996年   1篇
  1994年   1篇
  1988年   1篇
  1984年   1篇
  1982年   2篇
  1972年   1篇
  1971年   2篇
排序方式: 共有31条查询结果,搜索用时 15 毫秒
1.
Plasma expanders (PEs) are administered fluids to replace blood volume when massive blood loss has occured. Maltodextrin from tapioca starch was selected as a study candidate to prepare a colloid PE due to an uncomplicated production process. The formulations of mixture between tapioca maltodextrin and 0.9 % sodium chloride solution were prepared and then characterized. This was to investigate the effects of a dextrose equivalent (DE) and the concentration on the physical properties. Storage stability of each formulation was also determined and compared with clinically used PE [6 % hydroxyethyl starch (HES), 130/0.4]. The effects on the circulatory system in hamsters with hemorrhagic shock and resuscitation using prepared PE were also investigated. The results showed that low DE value led to high retrogradation, turbidity and viscosity but low colloid osmotic pressure and poor solubility. Among the prepared solutions, tapioca maltodextrin with DE6 at 10 % w/v concentration had comparable properties with 6 % HES 130/0.4. Animals resuscitated with 10 % DE6 PE had improved mean arterial blood pressure similar to those resuscitated with 6 % HES 130/0.4. However, several parameters in animals resuscitated with 10 % DE6 PE were lower than those resuscitated with 6 % HES 130/0.4, i.e., heart rate, functional capillary density. Therefore, if using tapioca maltodextrin for PE, some properties have to be considered and efficiently optimized.  相似文献   
2.
Mechanical vibration and acoustic noise are major obstacles in the development of high-density and high-spindle-speed hard disk drives. Torque ripple caused by the electrical driver is the main source of vibration and noise. This paper proposes a novel driver for spindle motors in hard disk drives based on the principle of position sensorless vector control. To reduce torque ripple, the proposed driver feeds the spindle motor in sinusoidal driving mode by which the sinusoidal current of the motor can be obtained. Experimental results of the proposed driver demonstrate the better driving performance in startup condition and fine sinusoidal current in steady state. Vibration testing shows significant improvement in the attenuation of vibration: the dominant vibration modes can be reduced to one tenth compared to that of a conventional driver. In addition, the mechanism of inducing torque ripple from time-harmonic currents is analyzed and the relationship between induced torque ripple and exhibited vibration modes is examined.  相似文献   
3.
Despite the huge technical and market potential for cost-effective energy efficiency investments in Southeast Asian markets, only a small fraction of this potential has been realised. Given that the major share of global future energy demand, and associated greenhouse gas emissions, will come from emerging economies, it is important to understand the barriers to mainstreaming energy efficiency into the financial sector. This paper focuses on public initiatives that support one of the main barriers: access to capital. The researchers chose Thailand as a case study because of the range of energy efficiency finance programmes that have been designed and implemented since the early 1990s. Interviews with 21 experts from government, the private sector and academia provided the core data for this research. The analysis employed a multi-level perspective and focused on the historical evolution of public support of energy efficiency finance in the country. We identified three distinct phases of public policy development over the past two decades. Despite an impressive variety of ambitious and creative programmes, the initiatives have not yet succeeded in integrating energy efficiency into the financial sector in a meaningful way. Some of the key lessons found are that (a) it is better to treat energy efficiency and renewable energy in separate financing initiatives, (b) governments find it challenging to design effective mechanisms to de-risk financial investments, and (c) international organisations play an important role in testing and facilitating the introduction of new financing approaches and mechanisms. In emerging economies, cost-effective implementation of energy efficiency measures is a promising alternative that can reduce the need for investment in large-scale power generation capacity. The researchers hope that this paper will contribute to more effective design of programmes to incentivise energy efficiency financing in Thailand and in other economies in Southeast Asia.  相似文献   
4.
This paper reports an experimental and simulation study on application of automated Venetian blind for daylighting in tropical climate. A horizontal blind system operating automatically under programmed control was constructed and integrated onto the glazed windows to form a window system with an automated blind in a room of a laboratory building. A dimming controller was also integrated to the lighting system of the room. Different operation schemes of the window system were devised and tested in the attempt to maximize energy savings while maintaining the quality of the visual environment in the room. Intensive measurement of illuminance of the interior space was undertaken during the experiments. A methodology for calculation of interior daylight illuminance and associated glare corresponding to the configurations of the experiments was adopted. The method was coded into a computer program. Results of calculation from the program agree well with those from experiments for all the schemes of operation conducted. The program was used to simulate the situation when each scheme of operation was implemented for a whole year. It was found that such window system with automated blind enabled energy savings of 80%, but a more sophisticated scheme also helped maintain the interior visual quality at high level.  相似文献   
5.
This paper presents an indoor and analytical study to evaluate the performance of a desiccant cooling system that uses silica gel as desiccant, electric light bulbs to simulate solar radiation, and forced flow of air through an IDC (integrated Desiccant/Collector). In the regeneration process, the rate at which water is removed from the desiccant increases with irradiation and decreases with air flowrate. In the air dehumidification process, the adsorption rate decreases with irradiation and increases slightly with flowrate. Comparisons between analytical calculations and experimental data show good agreement, and the calculations show that it should be possible to operate this system in tropical humid climates using the regeneration process in the day and the air dehumidification in the night time.  相似文献   
6.
By introducing a moving updated Lagrangian observer, this paper develops traveling finite elements with the capacity to handle the global response resulting from steadily moving contact fields. The generality of the results is such that large deformation kinematics and kinetics as well as the full compliment of inertial fields can be handled. To streamline the handling of nonlinear behavior, an elliptically constrained solution algorithm is also developed. Employing this algorithm, the results of several numerical benchmarking studies are presented which illustrate the capacity of the moving updated Lagrangian formulation as well as the potential effects of nonlinearity.  相似文献   
7.
In hot and humid region, air-conditioning is increasingly used to attain thermal comfort. Air-conditioning is highly energy intensive and it is desirable to develop alternative low-energy means to achieve comfort. In a previous experimental investigation using a room equipped with radiant cooling panel, it was found that cooling water kept to 25 °C could be used to attain thermal comfort under some situations, while water at such temperature would not cause condensation of moisture from air on the panel. This paper reports results of a series of whole-year simulations using TRNSYS computer code on applications of radiant cooling to a room model that represents the actual experimental room. Admitting the inability of radiant cooling to accept latent load, chilled water at 10 °C was supplied to cooling coil to precool ventilation air while water cooled by cooling tower was used for radiant cooling in daytime application. For night-time, cooling water from cooling tower supplied for radiant cooling was found to be sufficient to achieve thermal comfort. Such applications are considered to be more amenable to residential houses.  相似文献   
8.
A solar-regenerated liquid desiccant ventilation pre-conditioning system has been installed and experiments were carried out for a period of nine months covering rainy, cold, and hot seasons in a hot and humid climate (Thailand). A heat exchanger was used to cool the dehumidified air instead of typical evaporative cooling to maintain the dryness of the air. The use of solar energy at the regeneration process and cooling water from a cooling tower makes the system more passive. The evaporation rate at the regeneration process was always greater than the moisture removal rate at the dehumidification process indicating that the concentration of the desiccant in the system would not decrease and so the performance would not drop during continuous operation. The system could reduce the temperature of the delivered air by about 1.2 °C while the humidity ratio was reduced by 0.0042 kgw/kgda equivalent to 11.1% relative humidity reduction. The experimental results were also compared with models in literature.  相似文献   
9.
In Thailand, traditional houses and public buildings were constructed from materials of low thermal mass. Windows and doors in such buildings are well shaded. Open windows, doors, and even gaps in the raised floor allow all interior spaces in a building to be naturally ventilated. Prior to the introduction of air-conditioning, concrete began to replace wood as walling material. New large air-conditioned buildings have glazed and closed windows so all interior spaces require air-conditioning and forced ventilation. Under the present situation, there is a tendency to believe in the merit of thermally massive walls. This paper presents results from an experimental and simulation study on comparative energy and economic performance of thermally light and massive walls that are used to enclose air-conditioned spaces. The spaces are assumed to serve three residential functions and three commercial functions. Results related to residential functions reaffirm the merits of vernacular architecture. Results related to commercial functions are mixed. However, very massive walls are not economical.  相似文献   
10.
This paper considers the pre and post buckling behavior of general structures exposed to high temperature fields for long durations wherein creep effects become significant. The solution to this problem is made possible through the use of closed upper bounding constraint surfaces which enable the development of a new time stepping algorithm. This permits the stable and efficient solution of structural problems which exhibit indefinite tangent properties. Due to the manner of constraining/bounding successive iterates, the algorithm developed herein is largely self adaptive, inherently stable, sufficiently flexible to handle geometric material and boundary induced nonlinearity, and can be incorporated into either finite element or difference simulations. To illustrate the capability of the procedure, as well as, the physics of creep induced pre and post buckling behavior, the results of several numerical experiments are included.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号