首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   47篇
  免费   4篇
化学工业   5篇
能源动力   3篇
轻工业   4篇
无线电   12篇
一般工业技术   9篇
冶金工业   8篇
自动化技术   10篇
  2023年   1篇
  2022年   1篇
  2021年   4篇
  2020年   1篇
  2019年   3篇
  2018年   8篇
  2017年   6篇
  2016年   2篇
  2015年   2篇
  2014年   4篇
  2013年   1篇
  2012年   1篇
  2011年   3篇
  2010年   3篇
  2009年   2篇
  2008年   1篇
  2007年   1篇
  2006年   1篇
  2004年   1篇
  1997年   1篇
  1996年   1篇
  1995年   1篇
  1993年   1篇
  1981年   1篇
排序方式: 共有51条查询结果,搜索用时 15 毫秒
1.
Twitter is a radiant platform with a quick and effective technique to analyze users’ perceptions of activities on social media. Many researchers and industry experts show their attention to Twitter sentiment analysis to recognize the stakeholder group. The sentiment analysis needs an advanced level of approaches including adoption to encompass data sentiment analysis and various machine learning tools. An assessment of sentiment analysis in multiple fields that affect their elevations among the people in real-time by using Naive Bayes and Support Vector Machine (SVM). This paper focused on analysing the distinguished sentiment techniques in tweets behaviour datasets for various spheres such as healthcare, behaviour estimation, etc. In addition, the results in this work explore and validate the statistical machine learning classifiers that provide the accuracy percentages attained in terms of positive, negative and neutral tweets. In this work, we obligated Twitter Application Programming Interface (API) account and programmed in python for sentiment analysis approach for the computational measure of user’s perceptions that extract a massive number of tweets and provide market value to the Twitter account proprietor. To distinguish the results in terms of the performance evaluation, an error analysis investigates the features of various stakeholders comprising social media analytics researchers, Natural Language Processing (NLP) developers, engineering managers and experts involved to have a decision-making approach.  相似文献   
2.

At the chromosomal level of evolution, recombination is a major factor for genetic variations. However, recombination does not occur with equal frequency at various regions of genome. The recombination has the tendency to occur at specific region with higher frequency and with low frequency at other regions, and former regions are named as hot recombination regions whereas later are called cold regions for recombination. In this paper, we have developed supervised machine learning-based models using artificial neural network, support vector machine and Naïve Bayes for efficient and effective classification of such hot and cold recombination regions based on the nucleotide composition of sequences. All models were validated and tested using tenfold cross-validation. Furthermore, neural network model was validated using leave one out and random sampling techniques in addition to tenfold cross-validation. Moreover, models were evaluated using receiver-operating curve. Our results indicate that artificial neural network achieves the best result.

  相似文献   
3.
4.
BACKGROUND AND OBJECTIVES: Intermittent pneumatic compression (IPC) is an effective form of deep vein thrombosis prophylaxis for general surgery patients. The antithrombotic effect of IPC is thought to be the result of increased venous velocity and stimulation of endogenous fibrinolysis. However, the mechanism of enhanced fibrinolytic activity and the relative effects on normal and postthrombotic veins have not been defined. The purposes of this study are 1) to quantify changes in fibrinolytic activity with IPC; 2) to study the mechanism of fibrinolytic enhancement with IPC; and 3) to evaluate whether postthrombotic patients have the same capacity for fibrinolytic enhancement with IPC as do normal subjects. METHODS: Twelve volunteers (6 normal and 6 postthrombotic) had 5 IPC devices applied for 120 minutes in random fashion, 1 per week x 5 weeks. The devices included single-chamber, sequential, foot, calf, and long-leg compression. Subjects had an indwelling antecubital venous cannula placed for blood drawn at baseline, 60, 120, and 180 minutes after IPC devices were applied. Global fibrinolytic activity (euglobulin fraction, fibrin plate assay), tissue plasminogen activator (tPA) antigen (Ag) and activity (Act), plasminogen activator inhibitor-1 (PAI-1) Ag and Act, alpha-2-antiplasmin-plasmin complexes, and von Willebrand factor (vWF) antigen were assayed. RESULTS: A striking elevation in fibrinolytic activity was noted at 180 minutes with all devices in normal subjects and postthrombotic patients (p = 0.01-0.0001); however, baseline and stimulated fibrinolytic activity was attenuated in postthrombotic patients (<0.03). The tPA-Act increased only in normal subjects (3.8 +/- 1.9%) (p = 0.057), despite a decrease in plasma tPA-Ag, which was observed in both normal subjects (-12.4 +/- 3.8%) (p = 0.009) and patients (-17.2 +/- 3.1%) (p = 0.001). PAI-1-Ag decreased in both normal subjects (-13.4 +/- 3.8%) (p = 0.007) and patients (-12.0 +/- 3.1%) (p = 0.013) with a marked reduction in PAI-1-Act in both normal subjects (p = 0.003) and patients (p = 0.004). There were no changes in vWF, and alpha-2-antiplasmin-plasmin complexes increased only in postthrombotic patients (p = 0.021). CONCLUSIONS: Stimulation of endogenous fibrinolytic activity occurs after IPC, both in normal subjects and postthrombotic patients; however, baseline and overall fibrinolytic response in postthrombotic patients is reduced. The mechanism of increased fibrinolytic activity is likely because of a reduction in PAI-1, with a resulting increase of tPA activity.  相似文献   
5.
The hypothesis that heparin-coated perfusion circuits reduce thrombin formation and activity; fibrinolysis; and platelet, complement, and neutrophil activation was tested in 20 consecutive, randomized adults who had cardiopulmonary bypass. Twenty identical perfusion systems were used; in 10, all blood-contacting surfaces were coated with partially degraded heparin (Carmeda process; Medtronic Cardiopulmonary, Anaheim, Calif.). All patients received a 300 U/kg dose of heparin. Activated clotting times were maintained longer than 400 seconds. Cardiopulmonary bypass lasted 36 to 244 minutes. Blood samples for platelet count, platelet response to adenosine diphosphate, plasma beta-thromboglobulin, inactivated complement 3b, neutrophil elastase, fibrinopeptide A, prothrombin fragment F1.2, thrombin-antithrombin complex, tissue plasminogen activator, plasminogen activator inhibitor-1, plasmin alpha 2-antiplasmin complex, and D-dimer were obtained at these times: after heparin was given, 5 and 30 minutes after cardiopulmonary bypass was started, within 5 minutes after bypass was stopped, and 15 minutes after protamine was given. After cardiopulmonary bypass, tubing segments were analyzed for surface-adsorbed anti-thrombin, fibrinogen, factor XII, and von Willebrand factor by radioimmunoassay. Heparin-coated circuits significantly (p < 0.001) reduced platelet adhesion and maintained platelet sensitivity to adenosine diphosphate (p = 0.015), but did not reduce release of beta-thromboglobulin. There were no significant differences between groups at any time for fibrinopeptide A, prothrombin fragment F1.2, or thrombin-antithrombin complex or in the markers for fibrinolysis: D-dimer, tissue plasminogen activator, plasminogen activator inhibitor-1, and alpha 2-antiplasmin complex. In both groups, concentrations of prothrombin fragment F1.2 and thrombin-antithrombin complex increased progressively and significantly during cardiopulmonary bypass and after protamine was given. Concentrations of D-dimer, alpha 2-antiplasmin complex, and plasminogen activator inhibitor-1 also increased significantly during bypass in both groups. Fibrinopeptide A levels did not increase during bypass but in both groups increased significantly after protamine was given. No significant differences were observed between groups for levels of inactivated complement 3b or neutrophil elastase. Radioimmunoassay showed a significant increase in surface-adsorbed antithrombin on coated circuits but no significant differences between groups for other proteins. We conclude that heparin-coated circuits used with standard doses of systemic heparin reduce platelet adhesion and improve platelet function but do not produce a meaningful anticoagulant effect during clinical cardiopulmonary bypass. The data do not support the practice of reducing systemic heparin doses during cardiac operations with heparin-coated extracorporeal perfusion circuitry.  相似文献   
6.
This work presents a two-stage voltage multiplier (VM) useful in RF energy harvesting based applications. The proposed circuit is based on the conventional differential drive rectifier, in which the input RF signal has been level shifted using a simple arrangement. This signal is then used to drive the next stage, which has been formed by using gate cross-coupled transistors. As a result, the load driving capability of the proposed architecture increases. The load in this work has been emulated in terms of a parallel RC circuit. The architecture has been implemented using standard 0.18 \(\mu\)m CMOS technology. The measurements of the two-stage conventional VM (CVM) and proposed VM circuits were performed at ISM frequencies 13.56, 433, 915 MHz and 2.4 GHz for R\(_L\) of values 1, 5, 10, 3 and 100 K\(\Omega\) with a fixed value of C\(_L\) equal to 20 pF. The performance evaluation has been done in terms of the power conversion efficiency (PCE) and average output DC voltage. The measured results show an improvement in PCE of 5% (minimum) for 13.56, 433 and 915 MHz frequencies, and up to 2% improvement for a frequency value of 2.4 GHz at the targeted load condition of 5 K\(\Omega ||\)20 pF, when compared with the measured results of the CVM circuit.  相似文献   
7.
8.
The ionic liquid based on the 1‐n‐butyl‐3‐methylimidazolium cation has been prepared and used as an efficient catalytic medum for the chemoselective thioacetalization of carbonyl compounds. Furthermore, recycling and reuse of this ionic liquid medium has been demonstrated. Moreover, the use of this catalytic medium not only avoids the generation of waste but also provides a green process with minimal hazards.  相似文献   
9.
A facile one-pot synthesis of a water-soluble MnO nanocolloid (i.e., D-glucuronic acid-coated MnO nanoparticle) is presented. The MnO nanoparticle in the MnO nanocolloid was coated with a biocompatible and hydrophilic D-glucuronic acid, and its particle diameter was nearly monodisperse and ranged from 2 to 3 nm. The average hydrodynamic diameter of the MnO nanocolloid was estimated to be 5 nm. The MnO nanoparticle was nearly paramagnetic down to T=3 K. The MnO nanocolloid showed a high longitudinal water proton relaxivity of r1=7.02 s(-1) mM(-1) with the r2/r1 ratio of 6.83 due to five unpaired S-state electrons of Mn(II) ion (S=5/2) as well as a high surface to volume ratio of the MnO nanoparticle. High contrast in vivo T1 MR images were obtained for various organs, showing the capability of the MnO nanocolloid as a sensitive T1 MRI contrast agent. The suggested three key-parameters which control the r1 and r2 relaxivities of nanocolloids (i.e., the S value of a metal ion, the spin structure, and the surface to volume ratio of a nanoparticle) successfully accounted for the observed r1 and r2 relaxivities of the MnO nanocolloid.  相似文献   
10.
One of the important features of flanging process is elastic recovery during unloading leading to springback. The elastic recovery is associated with various tool and material parameters. It is difficult to analytically predict the elastic recovery accurately owing to the complex material deformation behavior. In this investigation, a commercially available Finite Element software is used for elasto-plastic analysis of flanging process. The springback is studied varying geometrical, material and friction parameters. The results of the simulation are validated with a few published experimental results.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号