排序方式: 共有8条查询结果,搜索用时 15 毫秒
1
1.
Study on Adsorption Behavior of Rare Earth Complexes on Nanometer-Size Titanium Dioxide with ICP-AES
Inrecentyears ,rareearthelements (REEs)havebeenwidelyusedinfunctionalmaterials ,cata lystsandotherproductsinindustry ,diagnosisreagentsofmagneticresonanceimaging (MRI)inmedicineandsomefertilizersinagricultureespeciallyinChina .However,asaresultoftheirusage ,moreandmoreREEsaregettingintotheenvironment,andalsointohumanbodyviafoodchain[1,2 ] .Itisnotclearwhetherrareearthelementsareessentialforman ,soitisveryurgenttostudythebiologicaleffectofrareearthelementsinhumanhealthandenvironment .Inthes… 相似文献
2.
Study of Direct Determination of Trace Lanthanum in Biological Samples by ICP-AES Combined with Fluo
StudyofDirectDeterminationofTraceLanthanuminBiologicalSamplesbyICP-AESCombinedwithFluorinationElectrothermalVaporizationTechn... 相似文献
3.
4.
目的:评价CT及X线在股骨头坏死分期中的诊断准确性及价值。方法:收集我院2016年6月-2018年6月收治的46例确诊为股骨头坏死患者的影像资料,所有患者均进行CT及X线检查,行CT检查的为CT组,行X线检查的为X线组。比较两组患者股骨头坏死的阳性检出率及0期、I期、II期、III期、IV期分期诊断检出率。结果:CT组患者的阳性检出率(82.6%)显著高于X线组(63.0%),二者差异有统计学意义(Χ2=4.449,P0.05);且CT组患者在0期、I期、II期股骨头坏死检出率高于X线组(均P0.05),而在III期、IV期的检出率,二者差异无统计学意义(均P0.05)。结论:CT对股骨头坏死的检出率较X线高,且在股骨头坏死的早期诊断中较占优势。 相似文献
5.
随着电气化铁路在铁路运输中的迅猛发展以及电压等级的不断提高,电气化铁路牵引负荷对电网的负序和谐波影响也随之增大。为了建立准确有效的电气化铁路牵引负荷模型以评估其对电网的影响程度,本文根据全国部分牵引变电所的实测数据,利用Matlab仿真软件对实测数据进行分析处理,得到其概率密度函数图以及对应的累积分布函数图。通过观察发现累积分布函数图之间存在一定规律,因此根据累积分布函数图,对牵引负荷实测数据进行分类整理,得到牵引负荷实测数据的分类。 相似文献
6.
DirectDeterminationofTraceTitaniuminHighPurityYtriumOxidebyFETV/ICPAESPengTianyou(彭天右),QinYongchao(秦永超),FanZiyu(范子瑜)JiangZu... 相似文献
7.
Determination of Trace Metal Impurities in Cerium Oxide by Fluorination-Assisted ETV-ICP-AES after HPLC Separation 总被引:2,自引:0,他引:2
A new method for the separation and detection of trace metal impurities in cerium oxide (CeO2) using HPLC combined with electrothermal vaporization (ETV)-ICP-AES was developed. This combination links the high separation power of HPLC and high sensitivity of ETV-ICP-AES. The 2-ethylhexyl hydrogen 2-ethylhexylphosphate (P507) resin was used as stationary phase for the separation of metallic impurities in order to eliminate severe spectral interferences of the matrix. The dilute nitric acid was adopted as mobile phase for eluting Cu, Mn, Ni and La. The separation process can be accomplished in about 30 min. After concentrating the eluate by evaporation, the trace impurities were determined by using ETV-ICP-AES with the addition of 6% PTFE slurry as chemical modifier. The proposed method was applied to the analysis of CeO2 with satisfactory recoveries. 相似文献
8.
1