Leukocyte depletion improves early postischemic ventricular performance in neonatal models of global myocardial ischemia. However, the rate of leukocyte reaccumulation after cardiopulmonary bypass and its subsequent impact on myocardial function is not known. This laboratory study examined the effect of leukocyte depletion on myocardial performance during the initial 6-hour period after bypass in an in situ, in vivo porcine model of neonatal cardiac surgery. Fifteen 3- to 5-day-old piglets (eight control and seven leukocyte depleted animals) were instrumented by placement of left ventricular short-axis sonomicrometry crystals and an intraventricular micromanometer catheter. Mechanical leukocyte depletion was achieved with Pall RC100 filters (Pall Biomedical, Inc., Fajardo, Puerto Rico) in the cardiopulmonary bypass circuit. Neonatal hearts were subjected to 90 minutes of hypothermic ischemia after a single dose of cold crystalloid cardioplegia. Two control animals died after the operation and were excluded from data analysis. Leukocyte filtration reduced the granulocyte count during initial myocardial reperfusion to 0.8% of control values. However, circulating granulocyte counts increased in leukocyte depleted animals throughout the postoperative period, reaching 68% of control values by 6 hours. Despite this rapid return of circulating granulocytes, animals subjected to leukocyte depletion had significantly better preservation of left ventricular performance (measured by preload recruitable stroke work, p < or = 0.02), left ventricular systolic function (measured by end-systolic pressure-volume relationship, p < or = 0.05), and ventricular compliance (p < or = 0.04) during the experiment. These changes in ventricular function were associated with a significant increase in left ventricular water content (p < or = 0.02) and tissue myeloperoxidase activity (p < or = 0.005) in control animals compared with leukocyte depleted animals. This study demonstrates that leukocyte depletion during initial reperfusion results in sustained improvement in postischemic left ventricular function despite the rapid return of granulocytes to the circulation. 相似文献
α,ω-Methacrylate-terminated poly(1,3-dioxolane)s (polyDXL) were synthesized by cationic ring-opening polymerization of DXL in the presence of methylene-bis(oxyethylmethacrylate) as transfer agent. If the initiator concentration is small compared with the transfer agent concentration, the molecular weights of the polymers are governed by the ratio of the reacted monomer to the reacted transfer agent. The α,ω-methacrylate-terminated polyDXLs obtained undergo free radical polymerization with formation of polyacetal networks. The properties of the networks as function of the molecular weight of the corresponding prepolymers are reported. 相似文献
A CEC-funded project has been performed to tackle the problem of producing an advanced Life Monitoring System (LMS) which would calculate the creep and fatigue damage experienced by high temperature pipework components. Four areas were identified where existing Life Monitoring System technology could be improved:
1. 1. the inclusion of creep relaxation
2. 2. the inclusion of external loads on components
3. 3. a more accurate method of calculating thermal stresses due to temperature transients
4. 4. the inclusion of high cycle fatigue terms.
The creep relaxation problem was solved using stress reduction factors in an analytical in-elastic stress calculation. The stress reduction factors were produced for a number of common geometries and materials by means of non-linear finite element analysis. External loads were catered for by producing influence coefficients from in-elastic analysis of the particular piping system and using them to calculate bending moments at critical positions on the pipework from load and displacement measurements made at the convenient points at the pipework. The thermal stress problem was solved by producing a completely new solution based on Green's Function and Fast Fourier transforms. This allowed the thermal stress in a complex component to be calculated from simple non-intrusive thermocouple measurements made on the outside of the component. The high-cycle fatigue problem was dealt with precalculating the fatigue damage associated with standard transients and adding this damage to cumulative total when a transient occurred.
The site testing provided good practical experience and showed up problems which would not otherwise have been detected. 相似文献