首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   39篇
  免费   2篇
化学工业   8篇
轻工业   8篇
无线电   3篇
一般工业技术   14篇
冶金工业   4篇
自动化技术   4篇
  2018年   1篇
  2017年   2篇
  2016年   2篇
  2015年   1篇
  2013年   5篇
  2012年   5篇
  2011年   3篇
  2010年   4篇
  2009年   2篇
  2007年   1篇
  2006年   4篇
  2005年   4篇
  2004年   1篇
  2002年   1篇
  2001年   1篇
  2000年   1篇
  1998年   1篇
  1996年   2篇
排序方式: 共有41条查询结果,搜索用时 31 毫秒
1.
Drying, water fractions, and water distribution were investigated for pine, birch, and reed pulps and pine–birch, pine–reed, and pine–birch–reed pulp mixtures. Gravimetrically determined drying times showed that the drying rates of the pulps decreased at two to four inflection points. Characterizations of the dried pulps by differential scanning calorimetry (DSC) showed a faster removal of free water than freezing and nonfreezing bound waters; all decreased simultaneously, however. DSC also revealed the critical water contents at which the free water and freezing bound water disappeared. The gravimetrically determined inflection points of the drying curves corresponded with the critical points determined by DSC. NMR line widths and images produced by 1H‐NMR imaging revealed the nature and regions of the pulp drying. The constant growth rate of the NMR line widths with decreasing water content appeared to change at two inflection points, which fell approximately in the same water content regions as the inflection points of the drying curves. © 2006 Wiley Periodicals, Inc. J Appl Polym Sci 100: 937–945, 2006  相似文献   
2.
The Dynamic Reference (DR) method has been developed for subjective image quality experiments in which original or undistorted images are unavailable. The DR method creates reference image series from test images. Reference images are presented to observers as a slide show prior to evaluating their quality. As the observers view the set of reference images, they determine the overall variation in quality within the set of test images. This study compared the performance of the DR method to that of the standardized absolute category rating (ACR) and paired comparison (PC) methods. We measured the performance of each method in terms of time effort and discriminability. The results showed that the DR method is faster than the PC method and more accurate than the ACR method. The DR method is especially suitable for experiments that require highly accurate results in a short time.  相似文献   
3.
During the production and recycling of asphalt concrete, bitumen in contact with inorganic particles is exposed to air at high temperatures. As a result an oxidation of bitumen, also known as aging, occurs. The reaction between bitumen and air at 163 °C was studied insitu with and without the presence of inorganic impurities by means of fourier transform infrared spectroscopy in the attenuated reflectance mode. This oxidation was discovered to be a step-wise reaction facilitated by the oxidation of thiols and creation of peroxides within the system. The rate of reaction was demonstrated to depend on the type of impurity present, of which iron (III) chloride was the strongest catalyst. It was further demonstrated that the oxidation reaction is inhibited by the adsorption of thiol species present in the system on copper particles. Combining copper with the iron (III) chloride-containing system also resulted in the inhibition of signal increase in the sulfoxide region of the spectra. The results of this preliminary research on the bitumen oxidation reaction presented are proposed for further research regarding control of aging of asphalt concrete, especially during the recycling works.  相似文献   
4.
Smoking is a major risk factor for several diseases including chronic obstructive pulmonary disease (COPD). To better understand the systemic effects of cigarette smoke exposure and mild to moderate COPD—and to support future biomarker development—we profiled the serum lipidomes of healthy smokers, smokers with mild to moderate COPD (GOLD stages 1 and 2), former smokers, and never-smokers (n = 40 per group) (ClinicalTrials.gov registration: NCT01780298). Serum lipidome profiling was conducted with untargeted and targeted mass spectrometry-based lipidomics. Guided by weighted lipid co-expression network analysis, we identified three main trends comparing smokers, especially those with COPD, with non-smokers: a general increase in glycero(phospho)lipids, including triglycerols; changes in fatty acid desaturation (decrease in ω-3 polyunsaturated fatty acids, and an increase in monounsaturated fatty acids); and an imbalance in eicosanoids (increase in 11,12- and 14,15-DHETs (dihydroxyeicosatrienoic acids), and a decrease in 9- and 13-HODEs (hydroxyoctadecadienoic acids)). The lipidome profiles supported classification of study subjects as smokers or non-smokers, but were not sufficient to distinguish between smokers with and without COPD. Overall, our study yielded further insights into the complex interplay between smoke exposure, lung disease, and systemic alterations in serum lipid profiles.  相似文献   
5.
6.
Research in accelerated pavement testing (APT) facilities has traditionally focused on the pavement performance such as rutting and fatigue cracking, but documentation on construction management and information of the actual pavement construction quality is limited. There are typically four critical factors that need to be considered to achieve the best possible outcome in construction: cost, schedule, construction process, and quality control, and management. With the objective of developing guidelines for planning and executing construction of a small-scale APT facility, this paper presents a case study documenting and evaluating the construction process and construction management efforts of two sensor-instrumented hot mix asphalt pavement test sections built in a small-scale APT facility. The focus of the experiment was to study bottom-up fatigue cracking of the flexible pavement structure. The presented information and lessons learned serve as a template and guide for agencies pursuing this type of research and pavement construction.  相似文献   
7.
The objective of these investigations was to determine the possible effects of the novel selective estrogen receptor modulator, ospemifene, on cytochrome P450 (CYP)-mediated drug metabolism. Ospemifene underwent testing for possible effects on CYP enzyme activity in human liver microsomes and in isolated human hepatocytes. Based on the results obtained in vitro, three Phase 1 crossover pharmacokinetic studies were conducted in healthy postmenopausal women to assess the in vivo effects of ospemifene on CYP-mediated drug metabolism. Ospemifene and its main metabolites 4-hydroxyospemifene and 4′-hydroxyospemifene weakly inhibited a number of CYPs (CYP2B6, CYP2C9, CYP2C19, CYP2C8, and CYP2D6) in vitro. However, only CYP2C9 activity was inhibited by 4-hydroxyospemifene at clinically relevant concentrations. Induction of CYPs by ospemifene in cultured human hepatocytes was 2.4-fold or less. The in vivo studies showed that ospemifene did not have significant effects on the areas under the plasma concentration-time curves of the tested CYP substrates warfarin (CYP2C9), bupropion (CYP2B6) and omeprazole (CYP2C19), demonstrating that pretreatment with ospemifene did not alter their metabolism. Therefore, the risk that ospemifene will affect the pharmacokinetics of drugs that are substrates for CYP enzymes is low.  相似文献   
8.
We recently described a novel homogeneous assay principle based on upconversion fluorescence resonance energy transfer (UC-FRET), where an upconverting phosphor (UCP) is utilized as a donor. The UC-FRET has now been applied to a competitive homogeneous immunoassay for 17beta-estradiol (E2) in serum, using a small-molecular dye as an acceptor. The assay was constructed by employing an UCP coated with an E2-specific recombinant antibody Fab fragment as a donor and an E2-conjugated small-molecular dye, Oyster-556, as an acceptor. Standard curves for the assay were produced both in buffer and in male serum. Sensitized acceptor emission was measured at 600 nm under continuous laser diode excitation at 980 nm. In buffer, the IC50 value of the assay was 1 nM and in serum 3 nM. The lower limits of detection (mean of zero calibrators, 3 SD) were 0.4 and 0.9 nM, respectively. The measurable concentration range extended up to 3 nM in buffer and 9 nM in serum. Equilibrium in the assay was reached in 30 min. The novel principle of UC-FRET has unique advantages compared to present homogeneous luminescence-based methods and can enable an attractive assay system platform for clinical diagnostics and for high-throughput screening approaches.  相似文献   
9.
Thin atomic layer deposited (ALD) Al2O3 coatings are efficient barriers against gases and vapors. Al2O3 coatings are, however, brittle and straining them generates defects that impair barrier properties. Flexibility of ALD-grown Al2O3 coatings on biopolymer substrates can be improved by separating thinner Al2O3 layers with inorganic-organic alucone layers. The number and size of defects were smaller for these nanolaminates compared to the thick Al2O3 films after straining, and hence straining deteriorated the oxygen barrier properties less when applied to the laminates than when applied to the Al2O3 coatings.  相似文献   
10.
Abstract— In this study, the effect of vibration on mobile‐phone text legibility caused by walking was examined. Legibility was measured as reading performance and subjective task load when reading from a mobile‐phone display while walking on a treadmill at 1.5 km/hour, 3 km/hour, and an individually defined speed (3.9 km/hour on average). Vibration was measured on the vertical, lateral, and fore‐and‐aft axes during walking. Vibration amplitude was calculated in five different frequency bands (1, 2, 4, 8, and 16 Hz), and correlated with the legibility measures. The amplitude increased most on the vertical and fore‐and‐aft axes as a function of walking speed, and the increase was largest in the 2‐Hz frequency band. Legibility decreased concurrently with increasing vibration. The strong correlation between vibration characteristics and legibility measures suggests that vibration characteristics could, to some degree, be used in estimating small‐display legibility while walking.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号