全文获取类型
收费全文 | 64篇 |
免费 | 0篇 |
专业分类
化学工业 | 16篇 |
机械仪表 | 1篇 |
能源动力 | 1篇 |
轻工业 | 1篇 |
无线电 | 16篇 |
一般工业技术 | 12篇 |
冶金工业 | 14篇 |
自动化技术 | 3篇 |
出版年
2020年 | 1篇 |
2016年 | 1篇 |
2014年 | 1篇 |
2013年 | 2篇 |
2012年 | 1篇 |
2011年 | 1篇 |
2010年 | 1篇 |
2009年 | 2篇 |
2008年 | 4篇 |
2007年 | 3篇 |
2006年 | 1篇 |
2005年 | 3篇 |
2004年 | 3篇 |
2003年 | 6篇 |
2002年 | 1篇 |
2001年 | 3篇 |
2000年 | 2篇 |
1998年 | 6篇 |
1997年 | 5篇 |
1996年 | 2篇 |
1995年 | 1篇 |
1994年 | 3篇 |
1993年 | 3篇 |
1992年 | 1篇 |
1991年 | 2篇 |
1989年 | 1篇 |
1988年 | 2篇 |
1984年 | 1篇 |
1972年 | 1篇 |
排序方式: 共有64条查询结果,搜索用时 281 毫秒
1.
K Ku K Nakayama Y Saitoh S Nosaka T Kitano T Hanada H Nagami K Yamada K Minami 《Canadian Metallurgical Quarterly》1997,64(2):399-403
Forty-eight Russell's viper bite patients (40 males, 8 females), age ranging from 16-76 years were studied. Out of 48 patients, 14 were found to have a prolonged whole blood clotting time test (WBCT) (i.e. incoagulable blood) (Group 1); 23 had a normal WBCT (i.e. clotted blood) (Group II); and 11 patients had a normal WBCT on admission which changed to non-clotting during the clinical course (Group III). Four patients from group I developed hypotension and 2 expired. The serum cortisol concentration (mean +/- SEM) on admission among groups I and II were 639 +/- 45.6 and 424 +/- 33.2 nmol/l respectively. The blood cortisol level in 35 subjects (controls) were 370.7 +/- 17.7 nmol/l (mean +/- SEM). There was a significant rise of blood cortisol in patients with incoagulable blood when compared to controls at the time of admission to the hospital (p < 0.05); but there was no significant difference among those patients with clotted blood. A much higher mean serum cortisol level was observed in 4 patients with hypotension as compared to 10 patients without shock. These patients with hypotension according to our study shown to have a favorable response to steroid therapy and eventually recovered. Whether higher doses of steroid in addition to antiserum confer extra benefit in suppressing nonspecific venom effects on the pituitary and/or adrenal is not known. 相似文献
2.
3.
K Tanaka K Inui M Kobayashi S Murase S Nosaka 《Canadian Metallurgical Quarterly》1998,69(2-3):190-197
A specific colony of Wistar rats was found in which the common carotid artery bifurcates at an unusually caudal position, thereby the carotid sinus nerve that originates from the bifurcation is elongated. The present study was done to determine whether this elongated nerve carries baro- and chemosensations in the same manner as the carotid sinus nerve of conventional rats or of other species. In chloralose-urethane anesthetized rats of this specific colony, the afferent discharges were recorded from the elongated carotid sinus nerve in response to a phenylephrine-induced rise in blood pressure and a fall in oxygen tension, as well as an increase in carbon dioxide tension in the respiratory gas. Reflex effects of electrical stimulation of the nerve were also examined. In nerve recording, the afferent discharges of the elongated carotid sinus nerve were increased by any of the perturbations, hypertensive, hypoxic or hypercapnic. Electrical stimulation of the elongated carotid sinus nerve caused an initial rise and a subsequent fall in blood pressure, bradycardia, and an increase of respiratory volume and rate. These results confirmed that the elongated carotid sinus nerve of rats in this colony contains both baroreceptor and chemoreceptor afferent fibers. It seems that this colony of rats proffers a beneficial material which will facilitate the studies to analyze the features and reflex functions of carotid body chemoreceptors and/or carotid sinus baroreceptors. 相似文献
4.
Hajime Miyama Kouichi Tanaka Yoshio Nosaka Nobuyuki Fujii Hiroshi Tanzawa Shoji Nagaoka 《应用聚合物科学杂志》1988,36(4):925-933
Polyacrylonitrile-g-poly(N,N-dimethylaminoethyl methacrylate) was synthesized photochemically and quaternized. The positively charged membranes made from the quaternized graftcopolymer showed high ultrafiltration rate for water by adding poly(vinyl alcohol) to casting solution and washing it out after the casting. In buffered saline solution, the permeability of the membranes was very small at pH below isoelectric point of albumin but increased markedly at higher pH. On the other hand, the permeability for γ-globulin was very small and did not show any pH dependence. 相似文献
5.
Sittidej Teekateerawej Junichi Nishino Yoshio Nosaka 《Journal of Applied Electrochemistry》2005,35(7-8):693-697
Two kinds of porous ceramic disks, having through-holes with diameters of 0.1 and 0.05 mm, were coated with TiO2 using two different starting solutions: titanyl(IV)acetylacetonate and a commercial titania sol (STS-01). The morphology
of these porous ceramics before and after TiO2 coating was observed by SEM. The TiO2-coated porous ceramics were examined as honeycomb photocatalytic microreactors. The photocatalytic activity was evaluated
using the decomposition of methylene blue solution for radiation angles of 0° and 10° with respect to the pore axis. The highest
photocatalytic activity was obtained for the porous ceramic having the pore diameter of 0.1 mm, coated with titanyl(IV)acetylacetonate
and irradiated with a light angle of 0° with respect to the pore axis. 相似文献
6.
7.
An experimental 50 Mbits/s pulse-code modulation-time-division multiple access (PCM-TDMA) system with time preassignment and time-assignment speech interpolation (TASI) features (called the TTT system) was built for use in a satellite test. This system was designed for application in the INTELSAT IV network and has the channel capacity of more than 700 telephone channels. This capacity can be increased up to twice when pulse-code modulation-time-assignment speech interpolation (PCM-TASI) is adopted. The field test was conducted via INTELSAT III in 1970 and satisfactory results were obtained, which encourages the introduction of the TDMA system for commercial use. 相似文献
8.
Nosaka H. Sano E. Ishii K. Ida M. Kurishima K. Yamahata S. Shibata T. Fukuyama H. Yoneyama M. Enoki T. Muraguchi M. 《Solid-State Circuits, IEEE Journal of》2004,39(8):1361-1365
We describe a 40-Gbit/s-class clock and data recovery (CDR) circuit with an extremely wide pull-in range. A Darlington-type voltage-controlled oscillator (VCO) is newly designed to cover the STM-256/OC-768 full-rate-clock frequencies with a wide frequency margin. We also describe a new lock detector using an exclusive-NOR gate. The CDR IC was fabricated using InP/InGaAs HBTs. Error-free operation and wide eye opening were confirmed for 40-, 43-, and 45-Gbit/s PRBS with a word length of 2/sup 31/ - 1. We attached a frequency search and phase control (FSPC) circuit to the chip as a new frequency acquisition aid, and this allows the CDR circuit to pull in throughout a 39-45-Gbit/s range. The peak-to-peak and rms jitter of the recovered clock were 3.6 and 0.48 ps, respectively. 相似文献
9.
Nakagawa G. Yamamoto T. Sasaki S. Norimatsu M. Yamamoto N. Nosaka T. Terada K. Tanaka K. Miura K. Yano M. 《Lightwave Technology, Journal of》1998,16(1):66-72
A high-power, high-sensitivity planar lightwave circuit (PLC) module, comprising a laser diode (LD) and a photodiode (PD) surface mounted on a PLC platform, has been realized by a novel passive alignment technique. We used a spot-size transformed LD and a corner-illuminated PD to form a highly efficient optical coupling between the devices and a PLC waveguide. We used the unique marker alignment method to ensure accurate positioning of them. The positioning precision achieved in the lateral direction was within 1 μm for the LD's and within 10 μm for the PD's. The rotational precision was within 0.4° for both chips. We realized high power operation (>8 mW) with a high receiver sensitivity (0.3 A/W). In this paper, we describe a high power, high sensitivity PLC incorporating a novel passive optical alignment technique for LD's and PD's 相似文献
10.
Ishii K. Nosaka H. Nakajima H. Kurishima K. Ida M. Watanabe N. Yamane Y. Sano E. Enoki T. 《Solid-State Circuits, IEEE Journal of》2002,37(9):1146-1151
Using InP-InGaAs heterojunction bipolar transistor (HBT) technology, we have successfully designed and fabricated a low-power 1:16 demultiplexer (DEMUX) integrated circuit (IC) and one-chip clock and data recovery (CDR) with a 1:4 DEMUX IC for 10-Gb/s optical communications systems. The InP-InGaAs HBTs were fabricated by a nonself-aligned process for high uniformity of device characteristics and producibility. The 1:16 DEMUX IC and the one-chip CDR with the 1:4 DEMUX IC consist of approximately 1200 and 460 transistors, respectively. We have confirmed error-free operation at 10 Gb/s for all data outputs of both ICs. The 1:16 DEMUX IC and the one-chip CDR with the 1:4 DEMUX IC consume only 1 W and 950 mW, respectively. These results demonstrate the feasibility of InP-InGaAs HBTs for low power high-integration optical communication ICs. 相似文献