首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   125篇
  免费   10篇
  国内免费   5篇
化学工业   39篇
金属工艺   4篇
机械仪表   1篇
建筑科学   3篇
能源动力   4篇
轻工业   20篇
水利工程   2篇
石油天然气   2篇
无线电   13篇
一般工业技术   26篇
冶金工业   3篇
自动化技术   23篇
  2023年   3篇
  2022年   5篇
  2021年   9篇
  2020年   13篇
  2019年   15篇
  2018年   18篇
  2017年   11篇
  2016年   8篇
  2015年   7篇
  2014年   11篇
  2013年   12篇
  2012年   4篇
  2011年   7篇
  2010年   6篇
  2009年   5篇
  2008年   3篇
  2006年   2篇
  2004年   1篇
排序方式: 共有140条查询结果,搜索用时 218 毫秒
1.
2.
Nonnegative matrix factorization (NMF) algorithms have been utilized in a wide range of real applications; however, the performance of NMF is highly dependent on three factors including: (1) choosing a problem dependent cost function; (2) using an effective initialization method to start the updating procedure from a near‐optimal point; and (3) determining the rank of factorized matrices prior to decomposition. Due to the nonconvex nature of the NMF cost function, finding an analytical‐based optimal solution is impossible. This paper is aimed at proposing an efficient initialization method to modify the NMF performance. To widely explore the search space for initializing the factorized matrices in NMF, the island genetic algorithm (IGA) is employed as a diverse multiagent search scheme. To adapt IGA for NMF initialization, we present a specific mutation operator. To assess how the proposed IGA initialization method efficiently enhances NMF performance, we have implemented state‐of‐the‐art initialization methods and applied to the Japanese Female Facial Expression dataset to recognize the facial expression states. Experimental results demonstrate the superiority of the proposed approach to the compared methods in terms of relative error and fast convergence.  相似文献   
3.
A simple, fast, and reliable liquid–liquid micro-extraction (LLME) method assisted by thermal ultrasound approach was developed for simultaneous determination of synthetic phenolic antioxidants (SPAs) in edible oils by high-performance liquid chromatography equipped with ultraviolet detector (HPLC-UV). The synthetic antioxidants were propyl gallate (PG), butylated hydroxyanisole (BHA), tert-butylhydroquinone (TBHQ), and butylated hydroxyltoluene (BHT). The best extraction conditions were observed were methanol/acetonitrile (1:1, v/v) as the solvent, ultrasound at 4 min, and a temperature of 40°C. The linearity of the calibration curves for the optimum conditions were R2 > 0.989 for all of the SPAs in a range from 1–200 μg ml−1. Relative standard deviation (RSD %) for five analysis was in range of 2.83% to 4.21%. Limit of detection (LOD) and limit of quantification (LOQ) were obtained in range of 0.012–0.06 and 0.04–0.2 μg g−1, respectively. With regard to recovery, a range of 91%–116% was calculated for the spiked edible oils.  相似文献   
4.
In this study, hydrogenated amorphous carbon thin films, structurally similar to diamond‐like carbon (DLC), were deposited on the surface of untreated and plasma nitrocarburised (Nitrocarburizing‐treated) stainless steel medical implants using a plasma‐enhanced chemical vapour deposition method. The deposited DLC thin films on the nitrocarburising‐treated implants (CN+DLC) exhibited an appropriate adhesion to the substrates. The results clearly indicated that the applied DLC thin films showed excellent pitting and corrosion resistance with no considerable damage on the surface in comparison with the other samples. The CN+DLC thin films could be considered as an efficient approach for improving the biocompatibility and chemical inertness of metallic implants.Inspec keywords: tissue engineering, bone, biomedical materials, electrochemistry, amorphous state, carbon, hydrogen, thin films, plasma CVD, adhesion, corrosion resistance, surface hardeningOther keywords: electrochemical performance, plasma nitrocarburised stainless steel medical implants, hydrogenated amorphous carbon thin films, bone tissue engineering, plasma‐enhanced chemical vapour deposition method, adhesion, corrosion resistance, biocompatibility, chemical inertness, metallic implants, C:H  相似文献   
5.
The characterization of an optical sensor membrane is described for simultaneous determination of sulfite and sulfide ions based on the immobilization of crystal violet on a triacetylcellulose membrane. The absorbance of the membranes decreased by increasing sulfite and sulfide concentration. The partial least squares (PLS-1) calibration model based on spectrophotometric measurement for simultaneous determination of sulfite and sulfide ions was applied. This method is based on the difference between the rate of the reaction of sulfide and sulfite with membranes in pH 7.0 buffer solution and at 25 °C. The experimental calibration matrix for partial least squares (PLS-1) calibration was designed with 18 samples. The cross-validation method was used for selecting the number of factors. The results showed that simultaneous determination could be performed in the range of 200–2000 μg mL−1 (2.5–25 mmol L−1) and 80–900 μg mL−1 (2.5–28.125 mmol L−1) for sulfite and sulfide, respectively. The sensor can readily be regenerated with water and the color is fully reversible. The sensor was successfully applied to the simultaneous determination of sulfide and sulfite in water samples.  相似文献   
6.
Since plasma is rich in many biomarkers used in clinical diagnostic experiments, microscale blood plasma separation is a primitive step in most of microfluidic analytical chips. In this paper, a passive microfluidic device for on-chip blood plasma separation based on Zweifach–Fung effect and plasma skimming was designed and fabricated by hot embossing of microchannels on a PMMA substrate and thermal bonding process. Human blood was diluted in various times and injected into the device. The main novelty of the proposed microfluidic device is the design of diffuser-shaped daughter channels. Our results demonstrated that this design exerted a considerable positive influence on the separation efficiency of the passive separator device, and the separation efficiency of 66.6 % was achieved. The optimum purity efficiency of 70 % was achieved for 1:100 dilution times.  相似文献   
7.
This paper presents a new model for networked control systems (NCSs) under transmission control protocol (TCP) as a multiple‐delay system by considering both sensor to controller and controller to actuator delays. An analytical TCP model has been considered for the network part, and an active queue management (AQM) controller is designed to regulate the desired queue length, which ensures holding the network induced delay and its variation within their lower bounds. The model is assumed to possess structured uncertainties due to the stochastic nature of the network. Robust stability and stabilization conditions are derived in terms of linear matrix inequalities (LMIs) by applying the Lyapunov‐Krasovskii stability criterion. Illustrative examples are presented and it has been shown that the proposed method will obtain less conservative results compared to the existing approaches in the literature.  相似文献   
8.
9.
A novel multilevel current source inverter (MCSI) configuration is introduced in this paper. The ability of handling with asymmetrical DC sources is one of the substantial advantages of the proposed inverter. In asymmetric mode, by appropriate selection of DC sources magnitude, a considerable increase can be obtained in the number of output levels without any manipulation on inverters’ hardware. In MCSIs, the number of required circuit devices is very important because the overall costs, circuit size, reliability and control complexity are dependent on them directly. The proposed inverter can generate all desired current levels using a lower number of elements. Besides, it is known that reduction of number of switches from conventional inverters imposes an undesired increase in total semiconductor device power (SDP). But, the total SDP of the proposed inverter is kept equal to conventional inverter. To validate the superiority of the proposed inverter, a full comparison is provided. Also, the computer simulation and experimental results are presented.  相似文献   
10.
Polyvinylpolypyrrolidone-supported chlorosulfonic acid has been successfully applied to perform one-pot reaction of arylaldehydes, urea, ethylacetoacetate, or cyclic 1,3-diketo compounds under solvent-free condition at 70°C to provide a series of dihydropyrimidinones and octahydroquinazolin-2,5-diones in good to excellent yields. The method offers several advantages such as high yield, short reaction time, simple workup, easy preparation, and reusability of the catalyst. The [PVPP-SO3H]+Cl? catalyst was characterized via Fourier transform infrared spectroscopy (FT-IR) and thermal gravimetric analysis (TGA). Moreover, the catalyst could be recycled several times without significant loss of its catalytic activity. Clean methodologies, easy work-up procedure, high yield, and simple preparation of the catalyst are some advantages of this article.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号