排序方式: 共有48条查询结果,搜索用时 15 毫秒
1.
2.
为了探索发射层厚度对指数掺杂Ga1-χAlχAs/GaAs光电阴极光学性能与光电发射性能的影响,实验制备了两种发射层厚度不同的阴极样品,并测试得到400μm~1 000 nm内反射率、透射率与光谱响应曲线.实验结果说明发射层2.0 μm厚的样品比1.6μm厚的样品性能更好.利用薄膜光学矩阵理论公式计算阴极膜系反射率、透射率、吸收率与发射层厚度的关系公式,并对原有的量子效率公式进行光谱反射率和短波截止限的修正.用修正后的公式仿真不同发射层厚度下光阴极吸收率与光谱响应曲线,指出发射层厚度对阴极光学性能与光电发射性能的不同影响.进一步计算得到指数掺杂的Ga1-χAlχAs/GaAs光电阴极最佳发射层厚度范围是1.8μm~2.4μm. 相似文献
4.
5.
The speed and quality of the image fusion always restrain each other.The real-time image fusion is one of the problems which needs to be studied and solved urgently.The windowing processing technology for the image fusion proposed in this paper can solve this problem in a certain extent.The windowing rules were put forward and the applicable scope for the windowing fusion and the calculation method for the maximum windowing area were determined.And,the results of the windowing fusion were analyzed,verified ... 相似文献
6.
研究了非制冷热成像系统功耗产生的主要原因,提出了一种具有低功耗特点的多工作温度热成像系统。从非晶硅焦平面阵列探测器噪声等效温差和探测率的计算公式入手,分析了非晶硅焦平面阵列探测器响应特性与工作温度的关系。数值分析显示,在- 40℃~60℃工作温度范围内,非晶硅焦平面阵列探测器具有一致性的响应性能,这为设计多工作温度热成像系统奠定了理论基础。对所设计的多工作温度热成像系统测试结果:在- 40℃~60℃环境温度范围内,热电稳定器的功耗小于350 mW,噪声等效温差小于120 mK.这表明该热成像系统既具有稳定的成像质量,又具有较小的系统动耗。 相似文献
7.
本科研训练是一种很好的实践教育手段,越来越多的高校利用科研训练提高本科生的综合素质.本文通过具体的例子介绍了我校本科生科研训练的实施情况,包括选题、训练内容和训练效果等方面.每个科研训练项目均经历了查阅资料、方案设计、方案评审和方案实施等过程,结果表明本科科研训练可以很好地培养学生的创新能力,提高学生分析问题和解决问题的能力,为学生研究生阶段的学习和工作打下了良好的基础. 相似文献
8.
红外系统捕获飞行弹丸时,必须保证该系统对飞行弹丸的作用距离大于弹丸到红外系统的距离,分析了传统的红外系统作用距离计算公式,考虑了弹丸在飞行过程中与红外系统之间的距离会随着飞行时间变化,而红外辐射在大气中的衰减随着波长和传输距离不同而变化,因此红外系统接收到的弹丸辐射会在弹丸飞行过程中随着时间而变化;同时考虑到弹丸在飞行中系统接收的红外辐射受天空背景影响和弹丸截面等效面积的辐射影响,从而重新提出了红外系统的作用距离模型。在简单弹道模型的基础上,计算并分析理论飞行距离与系统作用距离相互影响的关系,获得红外系统对弹丸发射过程捕获的最佳位置,为红外系统探测飞行弹丸的地点选取提供理论依据。 相似文献
9.
The reasons why thermal imaging systems consume power are analyzed, and a low power consumption design scheme is presented for the thermal imaging systems operating at multiple temperatures. The relation between the response performance of α-Si microbolometer detector and its operating temperature is studied by means of formulas of mierobolometer detector's noise equivalent temperature difference (NETD) and detectivity. Numerical analysis based on true parameters demonstrates that the detectivity decreases slightly and NETD increases slightly when operating temperature rises, which indicates that α-Si microbolometer detector has approximately uniform response in a wide operating temperature range. According to these analyses, a thermal imaging system operating at multiple temperatures is designed. The power of thermoelectric stabilizer (TEC) is less than 350 mW and NETD is less than 120 mK in the ambient temperature range of - 40℃- 60℃, which shows that this system not only outputs high-quality images but consumes low power. 相似文献
10.