摘    要:提出以比较地源热泵系统运行耗能量与供热锅炉耗能量的方法,来确定地源热泵系统冬季的节能量.考虑了检测日的室内外温度和节能标准规定的温度偏差,该方法引入了温度修正系数加以修正,并对实际检测工作中出现的问题进行了讨论.

关 键 词:地源热泵系统(GSHPS)  节能监测  温差修正

The measurement on the electricity-saving of the GSHPS
LIU Zi-qiang,WANG Jian-hui,LIU Wei,PENG Guo-hui. The measurement on the electricity-saving of the GSHPS[J]. Renewable Energy(China), 2009, 27(2): 80-82
Authors:LIU Zi-qiang  WANG Jian-hui  LIU Wei  PENG Guo-hui
Affiliation:Hebei Institute of Energy Resources;Shijiazhuang 050081;China
Abstract:This paper proposes a method to measure the energy-saving of the GSHPS.With this method,the energy-consuming of the GSHPS and the normal heating-boiler were compared,the deviations of the in-room and the out-room temperature was considered,and the temperature correction fac tor was used to modify the deviation.The problems in actual measurement work were also discussed.