首页 | 本学科首页   官方微博 | 高级检索  
     

电缆长度对采煤机变频调速系统性能影响的研究
引用本文:刘聪,刘振坚.电缆长度对采煤机变频调速系统性能影响的研究[J].工矿自动化,2014(2).
作者姓名:刘聪  刘振坚
作者单位:天地科技股份有限公司上海分公司;
摘    要:为了研究长电缆对采煤机变频调速性能的影响,对不同长度牵引电缆进行了加载试验。理论分析和试验研究表明,输出电缆对变频器和电动机的影响与电缆长度有密切关系,随着电缆长度增加,其不良影响明显加剧;可通过优化变频器参数改善电动机负载能力,利用滤波器有效抑制变频器输出谐波,从而减小长电缆对采煤机变频调速系统性能的负面影响。

关 键 词:采煤机  变频调速  牵引电缆  长电缆  滤波器

Research of influence of cable length on performance of frequency-conversion and speed-regulation system of shearer
Abstract:In order to research the influence of long cable on performance of frequency-conversion and speed-regulation of shearer,loading tests of traction cables with different lengths were done.The theoretical analysis and experimental results show that the effects to frequency converter and motor caused by output cable have close relationship with the length of the cable.As cable length increases,the bad effects become more serious.The negative effects caused by long cable on performance of frequencyconversion speed-regulation system of shearer can be reduced by optimizing frequency converter parameters to improve load capacity of the motor,and using filter to restrain output harmonic of frequency converter.
Keywords:shearer  frequency-conversion and speed-regulation  traction cable  long cable  filter
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号