摘    要:以某一实际变电站工程为例,对500 kV HGIS联合构架的温度效应进行了计算分析,分别对梁、柱等结构构件中温度效应的影响部位作了详细的研究,不仅定性的明确了承受温度效应的关键构件,而且定量分析了温度组合工况与大风组合工况的轴力比,为以后工程中联合构架的计算分析以及构件的概念设计提供依据。

关 键 词:联合构架  温度效应  关键构件  轴力比

The research of remperature effects on the 500 kV united framework of substation
LU Qi-liang , ZHOU Yuan-qiang , WANG Lei.The research of remperature effects on the 500 kV united framework of substation[J].Shanxi Architecture,2014(33):31-33.
Authors:LU Qi-liang  ZHOU Yuan-qiang  WANG Lei
Affiliation:( Jiangsu Electric Power Design Institute, Nanjing 211102, China)
Abstract:Based on a practical substation project,the temperature effects on the 500 kV HGIS united framework were calculated and analyzed.Respectively,as the structural members,beams and columns were studied in detail,not only to identify qualitatively the key components which withstand temperature effect,and analyze quantitatively the axial force ratio between the combined load case including temperature effect and the combined load case including high wind. The results of this paper provide a foundation for the analysis and conceptual design of the united framework in the future.
Keywords:united framework  temperature effect  key component  axial force ratio