引用本文:赵冰燃,吕桂萍. 球阀动水关闭应力分析[J]. 阀门, 2011, 0(3): 8-9
作者姓名:赵冰燃  吕桂萍
作者单位:厦门大学;哈尔滨大电机研究所;
摘    要:
通过对球阀动水关闭有限元应力分析得出,球阀球体关闭约60°时,球阀承受的应力最大。因此球阀进行有限元分析时,不仅要考虑球体全关闭工况,还要考虑球体在60°状态时的应力水平。

关 键 词:球阀  球体  应力分析  动水关闭

The stress analysis about spherical valve in dynamic water closing
ZHAO Bing-ran,LU Gui-ping. The stress analysis about spherical valve in dynamic water closing[J]. Valve, 2011, 0(3): 8-9
Authors:ZHAO Bing-ran  LU Gui-ping
Affiliation:ZHAO Bing-ran1,LU Gui-ping2(1.Xiamen University,Xiamen 361005,China,2.Harbin Institute of Large Electrical Machinery,Harbin 150040,China)
Abstract:
According to the finite element analysis,the stress of the spherical valve is the biggest when the valve plug is closing about 60 degree.The suggest is given in this page not only consider the valve plug close,but also consider the position of valve plug closing in 60 degree.
Keywords:spherical valve  valve plug  stress analysis  dynamic water closing  