Dimensioning of membrane bioreactors for municipal wastewater treatment.
Authors:Detlef Wedi  Adriano Joss
Affiliation:Engineering office ATM, Friedrich-Seele Str. 1b, 38122, Braunschweig, Germany.
Abstract:A basic procedure is proposed for dimensioning membrane bioreactors that is generally applicable. It evaluates the required membrane surface with particular consideration of loading combinations and hydraulic loading characteristics; it also takes into account ranges of minimum temperatures and corresponding fluxes as given by suppliers. The procedures, while likely to require further improvement, should make MBR design more transparent and aid the comparison of design variants.