流化床锅炉屏式过热器磨损爆管分析
引用本文:李天光,张香春,吴军莲.流化床锅炉屏式过热器磨损爆管分析[J].山东电力技术,2010(2):43-45.
作者姓名:李天光  张香春  吴军莲
作者单位:[1]华电国际电力股份有限公司,山东济南250011 [2]山东沾化热电有限公司,山东沾化256800 [3]华能济宁运河发电有限公司,山东济宁272100
摘    要:磨损是循环流化床锅炉中最常见的问题,严重制约着锅炉的安全运行。采用CFX软件对某电厂465t/h循环流化床锅炉屏式过热器磨损过程进行了数值模拟,详细分析了磨损原因,指出管屏变形是磨损爆管的主要原因,并针对磨损的原因,提出了相应措施。

关 键 词:流化床锅炉  屏式过热器  磨损  数值模拟

Analysis on Plated Superheater Tube Failure due to Wear in a CFB Boiler
Abstract:Wear is the most common problem in CFB boiler,which has a great impact on CFB boiler safely operating.Numerical simulating the wearing process of plated superheater in a CFB boiler is proved by CFX program and the result of wear is analyzed.It is concluded that tube failure was caused by wear which was resulted by distortion of plated superheater.Based on the conclusion,further improvement measures are given.
Keywords:circulating fluidized bed boiler  plated superheater  wear  numerical simulation