首页 | 本学科首页   官方微博 | 高级检索  
     

基于Bass模型的超临界机组和超超临界机组的扩散情景分析
引用本文:朱开伟,刘贞,吕指臣,蒲刚清,郭伟. 基于Bass模型的超临界机组和超超临界机组的扩散情景分析[J]. 电力建设, 2015, 36(6): 128-133. DOI: 10.3969/j.issn.1000-7229.2015.06.022
作者姓名:朱开伟  刘贞  吕指臣  蒲刚清  郭伟
作者单位:1.重庆理工大学工商管理学院,重庆市 400054;2.清华大学能源环境经济研究室,北京市 100084;3.重庆理工大学机械工程学院,重庆市 400054
基金项目:国家自然科学基金(71073095);教育部人文社会科学研究青年基金(10YJC630161)
摘    要:
本文在Bass模型原理的基础上,建立了关于政府投资、成本对超临界机组和超超临界机组的扩散影响模型,同时考虑了超临界机组和超超临界机组的竞争。研究发现:(1)超临界机组和超超临界机组的成本,对其扩散影响较小,而政府投资对超临界机组和超超临界机组的扩散影响较大;(2)在1.5倍和2倍于当前投资情景下,不同政府投资影响率下(Q值不同),超临界机组的最大市场装机容量分别为494.59,558.39,622.20 GW和434,518,602 GW,而超超临界机组的分别为905.42,841.61,777.81 GW和966,882,798 GW;(3)超临界机组和超超临界机组都将在2025年左右完成扩散过程。

关 键 词:超临界机组   超超临界机组   Bass模型  

Diffusion Scene Analysis on Supercritical Unit and Ultra Supercritical Units Based on Bass Model
ZHU Kaiwei,LIU Zhen,LYU Zhichen,PU Gangqing,GUO Wei. Diffusion Scene Analysis on Supercritical Unit and Ultra Supercritical Units Based on Bass Model[J]. Electric Power Construction, 2015, 36(6): 128-133. DOI: 10.3969/j.issn.1000-7229.2015.06.022
Authors:ZHU Kaiwei  LIU Zhen  LYU Zhichen  PU Gangqing  GUO Wei
Affiliation:1. Institute of Business Administration, Chongqing University of Technology, Chongqing 400054, China;2. Institute of Energy, Environment and Economic, Tsinghua University, Beijing 100084, China;3. Institute of mechanical engineering, Chongqing University of Technology, Chongqing 400054, China
Abstract:
Based on the principle of Bass model, a new model was established for the diffusion effects of the government investment, cost on supercritical units and ultra supercritical unit, with considering the the competition of supercritical units and ultra supercritical units . Research shows that :(1) compared to the affect of government invest, the cost of supercritical units and ultra supercritical units has less effect to their diffusion trend; (2)in 1.5 times and 2 times of the current investment situation, under the different Q value, the supercritical units eventually installed capacity are about 494.585, 558.39, 622.20 GW and 434, 518, 602 GW while the ultra supercritical units eventually installed capacity are about 905.42, 841.61, 777.81 GW and 966, 882, 798 GW; (3)around 2025 supercritical units and ultra supercritical units will both complete the diffusion process.
Keywords: supercritical units  ultra supercritical units  Bass diffusion mode  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《电力建设》浏览原始摘要信息
点击此处可从《电力建设》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号