首页 | 本学科首页   官方微博 | 高级检索  
     

基于蒸汽再热技术的供热优化改造试验研究
引用本文:蒋国安,张志业,李志龙,殷戈,谭锐,何秋婷,王炯铭.基于蒸汽再热技术的供热优化改造试验研究[J].电站系统工程,2022,38(1):25-28.
作者姓名:蒋国安  张志业  李志龙  殷戈  谭锐  何秋婷  王炯铭
作者单位:国能南京电力试验研究有限公司,国能(泉州)热电有限公司
基金项目:国家能源集团科技创新项目
摘    要:基于根据蒸汽再热技术实施供热改造后的某300 MW亚临界机组,依据"等发电功率"+"等供热量"的原则,通过进行三组对比性的性能试验研究,分析了"纯凝通流改造+供热优化"对机组运行经济性的影响.重点研究改造前后供热工况下机组性能变化,并对比分析改造前后纯凝工况下的机组性能.分析得出:纯凝通流改造前后纯凝THA工况下汽轮机...

关 键 词:300  MW亚临界机组  供热  优化  蒸汽再热  热耗率  供电煤耗率

Experimental Study on Heating Transformation of 300MW Subcritical Unit based on Steam Reheating Technology
JIANG Guo-an,ZHANG Zhi-ye,LI Zhi-long.Experimental Study on Heating Transformation of 300MW Subcritical Unit based on Steam Reheating Technology[J].Power System Engineering,2022,38(1):25-28.
Authors:JIANG Guo-an  ZHANG Zhi-ye  LI Zhi-long
Affiliation:(Guoneng Nanjing Electric Power Test and Research Co.,Ltd.;China Energy Investment Corporation Quanzhou Thermal Electric Power Co.,Ltd.)
Abstract:For a 300 MW subcritical unit after heat supply transformation according to steam reheating technology,based on the principle of"equal power generation"+"equal heat supply",the influence of"pure condensing flow transformation+heat supply optimization"on the unit operation economy is analyzed through three groups of comparative performance tests.The performance changes of unit under heating condition before and after the transformation are studied,and the performance of unit under the pure condensation condition before and after the transformation is analyzed.The analysis shows that the heat rate of steam turbine decreases by 331.8 kJ/kWh and the coal consumption rate of power supply decreases by 12.90 g/kWh under the THA condition before and after the pure condensing flow transformation;compared with the old heating mode,the heat consumption rate of the new heating mode decreased by 383.2 kJ/kWh and the coal consumption rate decreased by 14.91 g/kWh;the comprehensive energy-saving effect of pure condensing flow transformation and heat supply optimization shows that the heat consumption rate under the same working condition is reduced by 710.2 kJ/kWh,and the coal consumption rate of power supply is reduced by 27.63 g/kWh.The proportion of energy saving of heat supply optimization(14.91 g/kWh)in total energy saving(27.63 g/kWh)is 53.4%.
Keywords:300MW subcritical unit  heat supply  optimization  steam reheating  heat rate  coal consumption rate of power supply
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号