首页 | 本学科首页   官方微博 | 高级检索  
     

150m~3/h制氧机不出氧的故障分析与处理
引用本文:陈比舜.150m~3/h制氧机不出氧的故障分析与处理[J].深冷技术,2001(5).
作者姓名:陈比舜
作者单位:兰州石油化工机器总厂动力厂三气车间 兰州七里河730050
摘    要:介绍了 15 0m3/h制氧机不出氧的故障现象 ,通过检查和分析 ,找出了空压机排气量不足、膨胀机制冷效果差两大故障原因 ,并采取相应措施 ,使制氧机运转恢复正常

关 键 词:小型空气分离设备  故障  排气量少  制冷效果差  处理

Failure analysis of no oxygen coming out of 150m 3/h oxygen plant and solutions
Chen Bi,shun.Failure analysis of no oxygen coming out of 150m 3/h oxygen plant and solutions[J].Cryogenic Technology,2001(5).
Authors:Chen Bi  shun
Abstract:The failure of no oxygen coming out of 150m 3/h oxygen plant is described.The failure causes are found through examination and analysis,i.e.the deficient discharge capacity of the air compressor and the poor refrigerating efficiency of the expander.The operation of the oxygen plant has been recovered to normal level after taking relative measures.
Keywords:Small  air  separation  plant  Failure  Deficient  discharge  capacity  Poor refrigerating  efficiency  Solution
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号