首页 | 本学科首页   官方微博 | 高级检索  
     

新型冷弯薄壁型钢-混凝土组合楼盖耐火性能数值模拟研究
引用本文:王卫永,马杰,周绪红,石宇,马全涛. 新型冷弯薄壁型钢-混凝土组合楼盖耐火性能数值模拟研究[J]. 土木与环境工程学报, 2021, 43(2): 84-93
作者姓名:王卫永  马杰  周绪红  石宇  马全涛
作者单位:重庆大学 土木工程学院, 重庆 400045;日照大象房屋建设有限公司, 山东 日照 276800
基金项目:国家自然科学基金(51878096)
摘    要:冷弯薄壁型钢-混凝土组合楼盖主要由上部压型钢板-混凝土组合楼板和下部冷弯薄壁型钢拼合梁组成,当楼盖下侧发生火灾时,冷弯薄壁型钢梁和压型钢板会直接受火.为提升组合楼盖的耐火性能,在型钢梁的下翼缘固定防火板材,形成防火保护层,从而提出一种新型冷弯薄壁型钢-混凝土组合楼盖.然而,加入防火保护层后,楼盖的温度分布、变形和耐火极...

关 键 词:冷弯薄壁型钢  组合楼盖  耐火性能  有限元模拟
收稿时间:2020-08-25

Numerical analysis of fire resistance of a new type cold-formed thin-walled steel concrete composite floor
WANG Weiyong,MA Jie,ZHOU Xuhong,SHI Yu,MA Quantao. Numerical analysis of fire resistance of a new type cold-formed thin-walled steel concrete composite floor[J]. Journal of Civil and Environmental Engineering, 2021, 43(2): 84-93
Authors:WANG Weiyong  MA Jie  ZHOU Xuhong  SHI Yu  MA Quantao
Affiliation:School of Civil Engineering, Chongqing University, Chongqing 400045, P. R. China; Rizhao DSUN Building Construction Company Limited, Rizhao 276800, Shandong, P. R. China
Abstract:Cold-formed thin-walled steel concrete composite floor is fabricated with profiled steel sheet-concrete composite slab at the top and cold formed steel built-up beam at the bottom.When fire occurs on the lower side of the floor, the cold-formed thin-walled steel beams and profiled steel sheets will be directly exposed to fire. In order to improve the fire resistance of the floor, a new type cold-formed thin-walled steel concrete composite floor is proposed by fixing fireproof board on the lower flange of cold-formed steel beams to form a fire protection layer. However, the temperature distribution, deflection and fire resistance time of the new floor will change after adding fire protection, so fire resistance performance of the new floor needs to be studied. A simplified three-dimensional finite element model is established to analyze the influence of concrete slab thickness, beam height, load ratio, fire protection on the fire resistance of the new floor. It is found that the temperature at the same height of the steel beam is basically similar along the span direction but not uniform along the height direction when the direction of the profiled steel sheet is vertical to the steel beam.Increasing the thickness of concrete slab appropriately has little effect on fire resistance.In addition,the critical temperature of the hot flange with different cross-section sizes under the load ratio of 0.2~0.5 and the time-temperature curves of the hot flange with different fire protection are obtained, which can be used to estimate the fire-resistance time of the new floor.
Keywords:cold-formed thin-walled steel  composite floor  fire resistance  finite element simulation
点击此处可从《土木与环境工程学报》浏览原始摘要信息
点击此处可从《土木与环境工程学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号