考虑混凝土板组合效应的蜂窝钢梁柱连接抗震性能试验研究
引用本文:贾连光,姜莱,武金国,回锋,王春刚.考虑混凝土板组合效应的蜂窝钢梁柱连接抗震性能试验研究[J].建筑结构学报,2017,38(4):54-61.
作者姓名:贾连光  姜莱  武金国  回锋  王春刚
作者单位:1. 沈阳建筑大学 土木工程学院, 辽宁沈阳 110168; ; 2. 沈阳建筑大学建筑设计研究院, 辽宁沈阳 110168;; 3. 哈尔滨工业大学建筑设计研究院沈阳分院, 辽宁沈阳 110168
基金项目:国家自然科学基金项目(51578346)
摘    要:为了研究混凝土板组合效应对蜂窝梁柱连接抗震性能的影响,对无混凝土板和有混凝土板的正六边形蜂窝梁柱连接、普通组合梁柱连接进行拟静力试验。研究混凝土板组合效应对不同开孔率的蜂窝梁柱连接的破坏形态、承载能力、刚度、延性及耗能能力的影响。试验结果表明:蜂窝梁柱连接可以有效地控制塑性铰在近柱端第一个蜂窝孔处形成,实现塑性铰外移,降低在梁柱连接焊缝处发生脆性破坏的可能性;混凝土板的组合效应可以减小蜂窝梁剪切变形的影响,与无混凝土板的蜂窝梁柱连接相比,有混凝土板的蜂窝梁柱连接的滞回曲线更饱满;混凝土板的组合效应能够提高蜂窝梁柱连接的承载能力、延性、刚度及耗能性能,开孔率越大,组合效应越显著;混凝土板组合效应降低了塑性铰区的转动能力。

关 键 词:蜂窝梁柱连接  开孔率  抗震性能  拟静力试验  组合效应  

Experimental study on seismic performance of cellular beam column connections considering composite action of floor slab
JIA Lianguang,JIANG Lai,WU Jinguo,HUI Feng,WANG Chungang.Experimental study on seismic performance of cellular beam column connections considering composite action of floor slab[J].Journal of Building Structures,2017,38(4):54-61.
Authors:JIA Lianguang  JIANG Lai  WU Jinguo  HUI Feng  WANG Chungang
Abstract:In order to investigate the effect of composite action of floor slab on the seismic performance of cellular beam column connections, the hexagon-hole cellular beam column connections with and without composite floor slab and the solid web composite beam column connection were tested under cyclic loading to study the effect of composite action of floor slab on the failure modes, bearing capacity, rigidity, ductility and energy dissipation capacity of composite cellular beam column connections with different opening ratios. The experimental results indicate that the plastic hinge of cellular beam column connections are generated at the first cellular hole near the column, the plastic hinge is moved away from the column to reduce the possibility of brittle failure at the beam column connection weld. The composite action of floor slab can reduce the effect of shear deformation, and the hysteretic curves of cellular beam column connections with composite floor slab are fuller than those without composite floor slab. The composite action of floor slab can improve the bearing capacity, ductility, stiffness and energy dissipation capacity of cellular beam column connections. With the increase of the opening ratio, the combination effect is more significant, but the composite action of floor slab reduces the rotational capacity of plastic hinge regions.
Keywords:cellular beam column connection  composite action  opening ratio  quasi-static test  seismic performance  