首页 | 本学科首页   官方微博 | 高级检索  
     

压水堆蒸发器水位调节失控跳堆分析及在线诊断调整
引用本文:马蜀. 压水堆蒸发器水位调节失控跳堆分析及在线诊断调整[J]. 核科学与工程, 2009, 29(4)
作者姓名:马蜀
作者单位:大亚湾核电运营管理有限责任公司,广东,深圳,518124
摘    要:分析了核电站引发蒸发器给水控制系统(ARE)水位跳堆的主要原因和薄弱环节,建立了在功率运行状态下进行ARE主阀调节偏差在线调整和旁路阀调节偏差在线调整技术,提出并实施处理方案,解决了压水堆机组在启停过程中水位容易发生失控的技术难题.

关 键 词:核电站  水位调节  失控分析  诊断调整

Trip analysis and online diagnosis regulation for loosing water level control of the PWR steam generator
MA Shu. Trip analysis and online diagnosis regulation for loosing water level control of the PWR steam generator[J]. Chinese Journal of Nuclear Science and Engineering, 2009, 29(4)
Authors:MA Shu
Abstract:A detailed analysis for the main reason and vulnerability of trip at Feedwater Flow Control(ARE)has been made,ARE main valve and bypass valve regulation warp on-ine adjustment techniques under power operation state are established and solutions proposed to solve the difficult problem that the water level is easy to lose control during power unit starting and shutdown.
Keywords:nuclear power plant  water level control  analysis on losing control  diagnosis regulation