首页 | 本学科首页   官方微博 | 高级检索  
     


Design and test of a protective structure for the double vertical explosive welding of large titanium/steel plate
Authors:Changgen Shi  Zerui Sun  Zhonghang Fang  Linsheng Zhao  Hesheng Shi
Affiliation:1. PLA Army Engineering University, Nanjing 210007, China;2. Jiangsu Runbang New Materials Group, Nanjing 201803, China
Abstract:A comprehensive protective structure with rigidity and flexibility was put forward and designed in view of the quality and safety problems for the double vertical explosive welding of large titanium/steel cladding plate. The movement speed and displacement of the protective structure was calculated by establishing its physics model. The dynamics and stabilization properties were analyzed, and the protective structure parameters were optimized and devised. The comprehensive protective structure, which is composed of rigidity unit and flexibility wall, can bear the impact of detonation wave and the high-speed movement of the cladding plate. There are no damage and deformation in the protective structure and the cladding plate. The protective structure can be used many times. The bonding rate of the Ti/steel plate obtained was nearly 100%, and there is no deformation, surface cracks, and big wave and micro-defects. Therefore, the protective problems of the double vertical explosive welding can be solved effectively by the protective structure.
Keywords:large Ti-steel cladding plate|double vertical explosive welding|comprehensive protective structure|protective mechanism
本文献已被 CNKI 等数据库收录!
点击此处可从《中国焊接》浏览原始摘要信息
点击此处可从《中国焊接》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号