电能存储装置测试系统中Boost软开关变换器研究
引用本文:叶尚斌,刘帅,韦莉,张逸成,姚勇涛.电能存储装置测试系统中Boost软开关变换器研究[J].电子测量与仪器学报,2016,30(4):629-637.
作者姓名:叶尚斌  刘帅  韦莉  张逸成  姚勇涛
作者单位:同济大学电子与信息工程学院 上海 201804
基金项目:国家“863”计划(2011AA11A265,2011AA11A233)
摘    要:提出一种应用于电能存储装置测试系统中的新型交错并联Boost软开关变换器。该变换器采用一组部分复用的辅助网络,令主开关管实现了零电压(zero-voltage-transition,ZVT)开通与关断,辅助开关管实现了零电流(zero-current-transition,ZCT)开通与部分零电压关断,降低了开关损耗,提升了电路效率。开关过程中的dv/dt、di/dt得以降低,从噪声源上改善了变换器电磁兼容(electromagnetic compatibility,EMC)性能,对高频段噪声抑制效果明显。对拓扑结构、工作过程进行了分析,对宽范围工作的有效性与EMC性能的改善进行了论证,并搭建了1.5 k W原理样机进行试验研究,试验结果验证了理论分析的正确性。

关 键 词:测试系统  Boost变换器  软开关  开关损耗  EMC

Research on soft switched Boost converter in energy storage device testing system
Ye Shangbin,Liu Shuai,Wei Li,Zhang Yicheng and Yao Yongtao.Research on soft switched Boost converter in energy storage device testing system[J].Journal of Electronic Measurement and Instrument,2016,30(4):629-637.
Authors:Ye Shangbin  Liu Shuai  Wei Li  Zhang Yicheng and Yao Yongtao
Affiliation:College of Electronics and Information Engineering, Tongji University, Shanghai 201804, China,College of Electronics and Information Engineering, Tongji University, Shanghai 201804, China,College of Electronics and Information Engineering, Tongji University, Shanghai 201804, China,College of Electronics and Information Engineering, Tongji University, Shanghai 201804, China and College of Electronics and Information Engineering, Tongji University, Shanghai 201804, China
Abstract:This paper proposes a novel soft-switched interleaved Boost converter used in energy storage device tes-ting system.By sharing part of additional auxiliary network,the main switches are able to turn ON and OFF with zero-voltage-transition (ZVT),while auxiliary switches turn ON with zero-current-transition (ZCT)and OFF partly with ZVT.The switching losses are reduced,as well as the conversion efficiency is raised.Furthermore,thanks to soft-switching,dv/dt and di/dt during switching period are reduced,so as to improve electromagnetic compatibility (EMC)performance from the point of noise source,and significantly suppress high-frequency noise.In this paper, circuit configuration and operation analysis are presented,afterwards operation in wide range and improvement of EMC are demonstrated.A prototype rated at 1 .5 kW is established in the lab,and the experimental results verify the theory analysis.
Keywords:testing system  Boost converter  soft-switched  switching losses  EMC