The Study on the Ceramic Membrane Wastewater Reuse System with Pre-Ozonation and Coagulation |
| |
Authors: | Motoharu Noguchi Michiko Aoki Hideki Kozono Hiroshi Kouchiwa Yoshitake Yoda |
| |
Affiliation: | 1. Metawater Co., Ltd , Tokyo , 101-0041 , Japan;2. Tokyo Metropolitan Government , Tokyo , 163-8001 , Japan |
| |
Abstract: | A new wastewater reuse system using ozonation, coagulation and MF ceramic membrane (0.1 μm) filtration was developed. The testing was performed using secondary effluent treated at the wastewater treatment plant (WWTP) in Tokyo, Japan. The volume of treated water by the pilot study equipment is about 90 m3/day. The combination of pre-ozonation and coagulation processes achieves continuous stable membrane filtration with flux of 4m3/m2/day (167 LMH). A stable membrane filtration could be maintained by controlling ozone dosing rate depending on secondary effluent (raw water) quality fluctuation. The COD (Mn) removal ratio in raw water was 50 to 60%, and the color removal ratio satisfied 80% or higher. The quality of the treated water that was obtained from our pilot study was better than the California's standards. |
| |
Keywords: | Ozone Coagulation Ceramic Membrane Wastewater Reuse Turbidity Organic Matter Color |
|
|