首页 | 本学科首页   官方微博 | 高级检索  
     


An estimation of the performance limits and improvement of dry cooling on trough solar thermal plants
Authors:Huifang Deng  Robert F Boehm
Affiliation:Center for Energy Research, UNLV Box 454027, Las Vegas, NV 89154-4027, USA
Abstract:A study is reported of the potential performance of dry cooling on power generation. This is done in the context of a generic trough solar thermal power plant. The commercial power plant analysis code GateCycle is applied for this purpose. This code is used to estimate typical performance of both wet and dry cooling options. Then it is configured to estimate the performance of ideal wet and dry cooling options. The latter are defined as the condenser temperature being at the ambient wet bulb temperature or dry bulb temperature, respectively. Yearly power production of a solar power plant located in Las Vegas is presented for each of the cooling options. To move further toward approaching the possible improvement in dry cooling, the impact of a high-performance heat exchanger surface is evaluated. It is found that higher efficiency generation compared to current dry cooling designs is definitely possible. In fact the performance of these types of systems can approach that of wet cooling system units.
Keywords:Solar thermal power  Dry cooling  Efficiency  Flattened-tube surface
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号